LSLindsay Bs Schultz

Lindsay Bs Schultz

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Lindsay Bs Schultz has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Growing Rod versus Posterior Spinal Fusion Treatment of Juvenile Idiopathic Scoliosis: Unique Characteristics and Surgical Outcomes

    by Elizabeth M. Wacker, Lindsay Schultz, Nichole Leitsinger, Viral V. Jain, Peter F. Sturm

    Progressive spinal curvature in juvenile idiopathic scoliosis (JIS) is challenging to treat. When conservative management fails, treatments include growing rods (GRs) or posterior spinal fusion (PSF). The purpose of this study is to compare the patient characteristics and outcomes of GR and PSF treatment of JIS. We performed a retrospective review of demographic, radiographic, and surgical data for all JIS patients requiring surgical treatment between 2012 and 2020. Patients who underwent any GR treatment were compared to PSF patients. A total of 36 patients (13 GR, 23 PSF) were reviewed. PSF patients had a larger pre-operative spinal height (p = 0.002), but similar pre-operative major curve magnitudes (p = 0.558). PSF treatment resulted in similar change in the T1-S1 length (p = 0.002), but a greater correction of the curve magnitude (p < 0.055) compared to GR patients. Eight patients initially treated with GRs later underwent definitive PSF treatment. This subset of patients had a greater spinal height before PSF (p = 0.006), but similar immediate post-PSF T1-S1 lengths (p = 0.437) and smaller changes in spinal height from PSF (p = 0.020) than primary PSF patients. At final follow-up, patients who underwent primary PSF versus PSF after GR had similar spinal heights (p = 0.842). The surgical intervention chosen to manage progressive JIS often differs based on patient characteristics. While this choice may impact immediate outcomes, the outcomes at final follow up are similar.


  • Observed Length Increases of Magnetically Controlled Growing Rods are Lower Than Programmed

    by Sarah E. Ms Gilday, Mark S. Do Schwartz, Donita I. Bylski-Austrow, David L. Bse Glos, Lindsay Bs Schultz, Sara O’hAra, Viral V. Jain, Peter F. Md Sturm

    Background: Magnetically controlled growing rods (MCGRs) are increasingly used in the treatment of early onset scoliosis (EOS). Few studies have reported whether desired lengthening can reliably be achieved, or if prior spine instrumentation and large tissue depths affect lengthening. In this clinical study of EOS patients, it was hypothesized that increases in rod length would equal programmed increases, patients with prior spine instrumentation would lengthen less than patients without prior surgery, and larger tissue depths would decrease lengthening success. Methods: A retrospective chart review was conducted on EOS patients with single and dual MCGRs placed between April 2014 to September 2015 and distracted at a single institution. Rod distraction was measured at each visit using ultrasound. Differences between programmed and actual distraction for each patient, and between groups with and without prior spine instrumentation, were determined by 2-tailed t tests. Regression and correlation were used to determine the relationship between tissue depth and length increases. Results: Thirty-one patients were included, 18 males, 13 females, age 8.1 (±2.5) years, with major curves measuring 60 (±14.6) degrees at time of MCGR insertion. In the 12 patients with prior instrumentation, time from initial growing rod placement to MCGR insertion was 23.1 (±10.6) months. The number of surgical procedures before MCGR insertion was 2.8 (±2.0). Total length increase relative to the programmed distraction was 86% (±21) (P0.9). Total lengthening was inversely proportional to tissue depth (r 2=0.38, P<0.01); the decrease in lengthening achieved was 2.1%/mm of tissue depth. Conclusions: Increases in rod length were 14% lower than the programmed distraction. Prior instrumentation did not impact the amount of rod distraction. Greater distance between the rod and the skin surface negatively affected the magnitude of distraction.