LCLeyi Cai

Leyi Cai

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Leyi Cai has a total of 17 co-authors. Here are the top co-authors by number of shared publications:

  • Chuanxu Zhang

    A Department of Orthopaedics , The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University , Wenzhou , Zhejiang , China

    1 shared publication
  • Chunhui Chen

    A Department of Orthopaedics , The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University , Wenzhou , Zhejiang , China

    1 shared publication
  • Chunhui Chen

    Department of Orthopaedic Surgery, The Second Affiliated Hospital and Yuying Children’s Hospital of Wenzhou Medical University, Wenzhou, China

    1 shared publication
  • Hua Chen

    Department of Orthopaedics, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, 109 Xue Yuan Xi Road, Wenzhou, 325000, Zhejiang, China.

    1 shared publication
  • Jian-Zhong Kong

    Department of Orthopaedic Surgery, The Second Affiliated Hospital and Yuying Children’s Hospital of Wenzhou Medical University, Second Medical School of Wenzhou Medical University, 109 Xueyuanxi Road, Wenzhou, 325027, Zhejiang, China

    1 shared publication
  • Jianjun Hong

    A Department of Orthopaedic Surgery , The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University , Wenzhou , China

    1 shared publication

Latest Publications

  • Open Access

    The efficacy of using 3D printing models in the treatment of fractures: a randomised clinical trial

    by Chunhui Chen, Leyi Cai, Wenhao Zheng, Jianshun Wang, Xiaoshan Guo, Hua Chen

    The aim of this study was to evaluate the efficacy of the use of three-dimensional (3D) printing models for preoperative planning in cases of complex fracture. In total, 48 patients with AO type C fractures of the distal radius were enrolled in the study between January 2014 and January 2015. They were divided randomly into 3D model (n = 23) and routine treatment (n = 25) groups. A 3D digital model of each distal radius fracture in the former group was constructed. The model was exported to a 3D printer for construction of a full solid model. During each operation, the operative time, amount of blood loss, and frequency of intraoperative fluoroscopy were recorded, which were regarded as primary outcome measures. Patients were followed to evaluate surgical outcomes by Gartland–Werley scores, radiological evaluation, and range of motion of wrist, and these were regarded as the secondary outcome measures. In addition, we invited surgeons and patients to complete questionnaires. The treatment of complex fractures using the 3D printing approach reduced the frequency of intraoperative fluoroscopy, blood loss volume, and operative time, but did not improve postoperative function compared with routine treatment. The patients wanted the doctor to use the 3D model to describe the condition and introduce the operative plan because it facilitated their understanding. The orthopaedic surgeons thought that the 3D model was useful for communication with patients, but were much less satisfied with its use in preoperative planning. Our study revealed that 3D printing models effectively help the doctors plan and perform the operation and provide more effective communication between doctors and patients, but can not improve postoperative function compared with routine treatment. This trial was registered at the Chinese Clinical Trial Registry on May 9, 2017 (ChiCTR-IRP-17011343, http://www.chictr.org.cn/showproj.aspx?proj=19264 ).


  • Treatment of Die-Punch Fractures with 3D Printing Technology

    by Chunhui Chen, Leyi Cai, Chuanxu Zhang, Jianshun Wang, Xiaoshan Guo, Yifei Zhou

    Purpose: We evaluated the feasibility, accuracy and effectiveness of applying three-dimensional (3D) printing technology for preoperative planning for die-punch fractures. Methods: A total of 107 patients who underwent die-punch fracture surgery were enrolled in the study. They were randomly divided into two groups: 52 cases in the 3D model group and 55 cases in the routine group. A 3D digital model of each die-punch fracture was reconstructed in the 3D group. The 3D digital model was imported to a 3D printer to build the full solid model. The operation time, blood loss volume, and the number of intraoperative fluoroscopy were recorded. Follow-up was performed to evaluate the patients' surgical outcomes. Results: Treatment of die-punch fractures using the 3D printing approach reduced the number of intraoperative fluoroscopy, blood loss volume, and operation time, but did not improve wrist function compared to those in the routine group. The patients wanted the doctor to use the 3D model to introduce the condition and operative plan because it was easier for them to understand. The orthopedic surgeons thought that the 3D model was useful for communicating with their patients, but their satisfaction with the preoperative plan was much lower than the benefit of using the 3D model to communicate with their patients. Conclusions: 3D printing technology produced more accurate morphometric information for orthopedists to provide personalized surgical planning and communicate better with their patients. However, it is difficult to use widely in the department of orthopedics.


  • Open Access

    Comparison of percutaneous cannulated screw fixation and calcium sulfate cement grafting versus minimally invasive sinus tarsi approach and plate fixation for displaced intra-articular calcaneal fractures: a prospective randomized controlled trial

    by Yongzeng Feng, Xiaolong Shui, Jianshun Wang, Leyi Cai, Yang Yu, Xiaozhou Ying, Jianzhong Kong, Jianjun Hong

    The management of displaced intra-articular calcaneal fractures (DIACFs) remains challenging and controversial. A prospective randomized controlled trial was conducted to compare percutaneous reduction, cannulated screw fixation and calcium sulfate cement (PR+CSC) grafting with minimally invasive sinus tarsi approach and plate fixation (MISTA) for treatment of DIACFs. Ultimately, 80 patients with a DIACFs were randomly allocated to receive either PR+CSC (N = 42) or MISTA (N = 38). Functional outcomes were evaluated using the American Orthopaedic Foot and Ankle Society (AOFAS) hindfoot scores. Radiological results were assessed using plain radiographs and computed tomography (CT) scans, and postoperative wound-related complications were also recorded. The average time from initial injury to operation and the average operation time in the PR+CSC group were both significantly shorter than those in the MISTA group (p < 0.05). There were significantly fewer complications in the PR+CSC group than those in the MISTA group (7.1 % vs 28.9 %, p < 0.001). The calcaneal width immediate postoperatively and at the final follow-up in the MISTA group were obviously improved compared to those in the PR+CSC group (p < 0.001). The variables of sagittal motion and hindfoot motion of the AOFAS scoring system in the PR+CSC group were significantly higher than those in the MISTA group (p < 0.05). The good and excellent results in the two groups were comparable for Sanders Type-II calcaneal fractures, but the good to excellent rate in the MISTA group was significantly higher for Sanders Type-III fractures (p < 0.05). The clinical outcomes are comparable between the two minimally invasive techniques in the treatment of Sanders Type-II DIACFs. The PR+CSC grafting is superior to the MISTA in terms of the average time between initial injury and operation, operation time, wound-related complications and subtalar joint activity. However, the MISTA has its own advantages in improving the calcaneal width, providing a more clear visualization and accurate reduction of the articular surface, especially for Sanders Type-III DIACFs. ChiCTRIOR16008512 . 21 May 2016.