Paul Mos
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Paul Mos has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Claudio Bruschini
École Polytechnique Fédérale de Lausanne
4 shared publications - Edoardo Charbon
École Polytechnique Fédérale de Lausanne
4 shared publications - Andrei Ardelean
Advanced Quantum Architecture Laboratory École polytechnique fédérale de Lausanne 2002 Neuchâtel Switzerland
1 shared publication - Arin Can Ulku
École Polytechnique Fédérale de Lausanne
1 shared publication - Augusto Garuccio
Dipartimento Interateneo di Fisica, Università degli studi di Bari, I-70126 Bari, Italy
1 shared publication - Bohumil Stoklasa
Department of Optics, Palacký University, Olomouc, Czech Republic
1 shared publication
Latest Publications
- Open Access
Time-Resolved Laser Speckle Contrast Imaging (TR-LSCI) of Cerebral Blood Flow Response to Intracranial Pressure Elevation
Significance: Cerebral autoregulation (CA) reflects the dynamic coupling among cerebral blood flow (CBF), intracranial pressure (ICP), and arterial blood pressure (ABP); its failure contributes to secondary brain injury. Existing bedside methods rely on indirect or spatially limited CBF surrogates and cannot resolve microvascular flow dynamics across space, depth, and time. Aim: To develop, optimize, and apply a scalable, noncontact time-resolved laser speckle contrast imaging (TR-LSCI) platform for depth-sensitive, high-speed, wide-field CBF imaging during controlled ICP perturbations. Approach: TR-LSCI synchronizes a 20-MHz pulsed laser with a time-gated, single-photon avalanche diode (SPAD) camera (512 × 512 pixels) to detect diffuse photons at varying path lengths, enabling depth-resolved microvascular CBF imaging. Benchtop and mobile TR-LSCI systems were applied in adult rats and a neonatal piglet with synchronized invasive ICP and ABP measurements. Results: TR-LSCI captured spatially heterogeneous, pulsatile CBF dynamics at up to 52 Hz over large cortical fields of view, with heart rate estimates statistically equivalent to those from ICP and ABP. Multivariable analysis identified reproducible, phase-dependent CA transitions encompassing preserved autoregulation, ABP-driven compensation, and ICP-constrained CBF suppression; notably, CBF alone exhibited distinct phase signatures. Conclusions: TR-LSCI enables dynamic, physiology-informed neurovascular monitoring and supports future bedside CA assessment.
Open AccessTime-Resolved Laser Speckle Contrast Imaging (TR-LSCI) of Cerebral Blood Flow Response to Intracranial Pressure Elevation
Significance: Cerebral autoregulation (CA) reflects the dynamic coupling among cerebral blood flow (CBF), intracranial pressure (ICP), and arterial blood pressure (ABP); its failure contributes to secondary brain injury. Existing bedside methods rely on indirect or spatially limited CBF surrogates and cannot resolve microvascular flow dynamics across space, depth, and time. Aim: To develop, optimize, and apply a scalable, noncontact time-resolved laser speckle contrast imaging (TR-LSCI) platform for depth-sensitive, high-speed, wide-field CBF imaging during controlled ICP perturbations. Approach: TR-LSCI synchronizes a 20-MHz pulsed laser with a time-gated, single-photon avalanche diode (SPAD) camera (512 × 512 pixels) to detect diffuse photons at varying path lengths, enabling depth-resolved microvascular CBF imaging. Benchtop and mobile TR-LSCI systems were applied in adult rats and a neonatal piglet with synchronized invasive ICP and ABP measurements. Results: TR-LSCI captured spatially heterogeneous, pulsatile CBF dynamics at up to 52 Hz over large cortical fields of view, with heart rate estimates statistically equivalent to those from ICP and ABP. Multivariable analysis identified reproducible, phase-dependent CA transitions encompassing preserved autoregulation, ABP-driven compensation, and ICP-constrained CBF suppression; notably, CBF alone exhibited distinct phase signatures. Conclusions: TR-LSCI enables dynamic, physiology-informed neurovascular monitoring and supports future bedside CA assessment.
- Open Access
- 26 July 2023
- Published by Association for Computing Machinery (ACM) in ACM Transactions on Graphics
- Vol. 42 (4) , 1-16
Seeing Photons in Color
Megapixel single-photon avalanche diode (SPAD) arrays have been developed recently, opening up the possibility of deploying SPADs as generalpurpose passive cameras for photography and computer vision. However, most previous work on SPADs has been limited to monochrome imaging. We propose a computational photography technique that reconstructs high-quality color images from mosaicked binary frames captured by a SPAD array, even for high-dyanamic-range (HDR) scenes with complex and rapid motion. Inspired by conventional burst photography approaches, we design algorithms that jointly denoise and demosaick single-photon image sequences. Based on the observation that motion effectively increases the color sample rate, we design a blue-noise pseudorandom RGBW color filter array for SPADs, which is tailored for imaging dark, dynamic scenes. Results on simulated data, as well as real data captured with a fabricated color SPAD hardware prototype shows that the proposed method can reconstruct high-quality images with minimal color artifacts even for challenging low-light, HDR and fast-moving scenes. We hope that this paper, by adding color to computational single-photon imaging, spurs rapid adoption of SPADs for real-world passive imaging applications.
- 26 July 2023
- Published by Association for Computing Machinery (ACM) in ACM Transactions on Graphics
- Vol. 42 (4) , 1-16
Open AccessSeeing Photons in Color
Megapixel single-photon avalanche diode (SPAD) arrays have been developed recently, opening up the possibility of deploying SPADs as generalpurpose passive cameras for photography and computer vision. However, most previous work on SPADs has been limited to monochrome imaging. We propose a computational photography technique that reconstructs high-quality color images from mosaicked binary frames captured by a SPAD array, even for high-dyanamic-range (HDR) scenes with complex and rapid motion. Inspired by conventional burst photography approaches, we design algorithms that jointly denoise and demosaick single-photon image sequences. Based on the observation that motion effectively increases the color sample rate, we design a blue-noise pseudorandom RGBW color filter array for SPADs, which is tailored for imaging dark, dynamic scenes. Results on simulated data, as well as real data captured with a fabricated color SPAD hardware prototype shows that the proposed method can reconstruct high-quality images with minimal color artifacts even for challenging low-light, HDR and fast-moving scenes. We hope that this paper, by adding color to computational single-photon imaging, spurs rapid adoption of SPADs for real-world passive imaging applications.
- Open Access
Coupling a Recurrent Neural Network to SPAD TCSPC Systems for Real-time Fluorescence Lifetime Imaging
Fluorescence lifetime imaging (FLI) has been receiving increased attention in recent years as a powerful diagnostic technique in biological and medical research. However, existing FLI systems often suffer from a tradeoff between processing speed, accuracy, and robustness. In this paper, we propose a robust approach that enables fast FLI with no degradation of accuracy. The approach is based on a SPAD TCSPC system coupled to a recurrent neural network (RNN) that accurately estimates the fluorescence lifetime directly from raw timestamps without building histograms, thereby drastically reducing transfer data volumes and hardware resource utilization, thus enabling FLI acquisition at video rate. We train two variants of the RNN on a synthetic dataset and compare the results to those obtained using center-of-mass method (CMM) and least squares fitting (LS fitting). Results demonstrate that two RNN variants, gated recurrent unit (GRU) and long short-term memory (LSTM), are comparable to CMM and LS fitting in terms of accuracy, while outperforming them in background noise by a large margin. To explore the ultimate limits of the approach, we derived the Cramer-Rao lower bound of the measurement, showing that RNN yields lifetime estimations with near-optimal precision. Moreover, our FLI model, which is purely trained on synthetic datasets, works well with never-seen-before, real-world data. To demonstrate real-time operation, we have built a FLI microscope based on Piccolo, a 32x32 SPAD sensor developed in our lab. Four quantized GRU cores, capable of processing up to 4 million photons per second, are deployed on a Xilinx Kintex-7 FPGA. Powered by the GRU, the FLI setup can retrieve real-time fluorescence lifetime images at up to 10 frames per second. The proposed FLI system is promising and ideally suited for biomedical applications.
Open AccessCoupling a Recurrent Neural Network to SPAD TCSPC Systems for Real-time Fluorescence Lifetime Imaging
Fluorescence lifetime imaging (FLI) has been receiving increased attention in recent years as a powerful diagnostic technique in biological and medical research. However, existing FLI systems often suffer from a tradeoff between processing speed, accuracy, and robustness. In this paper, we propose a robust approach that enables fast FLI with no degradation of accuracy. The approach is based on a SPAD TCSPC system coupled to a recurrent neural network (RNN) that accurately estimates the fluorescence lifetime directly from raw timestamps without building histograms, thereby drastically reducing transfer data volumes and hardware resource utilization, thus enabling FLI acquisition at video rate. We train two variants of the RNN on a synthetic dataset and compare the results to those obtained using center-of-mass method (CMM) and least squares fitting (LS fitting). Results demonstrate that two RNN variants, gated recurrent unit (GRU) and long short-term memory (LSTM), are comparable to CMM and LS fitting in terms of accuracy, while outperforming them in background noise by a large margin. To explore the ultimate limits of the approach, we derived the Cramer-Rao lower bound of the measurement, showing that RNN yields lifetime estimations with near-optimal precision. Moreover, our FLI model, which is purely trained on synthetic datasets, works well with never-seen-before, real-world data. To demonstrate real-time operation, we have built a FLI microscope based on Piccolo, a 32x32 SPAD sensor developed in our lab. Four quantized GRU cores, capable of processing up to 4 million photons per second, are deployed on a Xilinx Kintex-7 FPGA. Powered by the GRU, the FLI setup can retrieve real-time fluorescence lifetime images at up to 10 frames per second. The proposed FLI system is promising and ideally suited for biomedical applications.
- Open Access
- 12 July 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (14) , 6414
Towards Quantum 3D Imaging Devices
We review the advancement of the research toward the design and implementation of quantum plenoptic cameras, radically novel 3D imaging devices that exploit both momentum–position entanglement and photon–number correlations to provide the typical refocusing and ultra-fast, scanning-free, 3D imaging capability of plenoptic devices, along with dramatically enhanced performances, unattainable in standard plenoptic cameras: diffraction-limited resolution, large depth of focus, and ultra-low noise. To further increase the volumetric resolution beyond the Rayleigh diffraction limit, and achieve the quantum limit, we are also developing dedicated protocols based on quantum Fisher information. However, for the quantum advantages of the proposed devices to be effective and appealing to end-users, two main challenges need to be tackled. First, due to the large number of frames required for correlation measurements to provide an acceptable signal-to-noise ratio, quantum plenoptic imaging (QPI) would require, if implemented with commercially available high-resolution cameras, acquisition times ranging from tens of seconds to a few minutes. Second, the elaboration of this large amount of data, in order to retrieve 3D images or refocusing 2D images, requires high-performance and time-consuming computation. To address these challenges, we are developing high-resolution single-photon avalanche photodiode (SPAD) arrays and high-performance low-level programming of ultra-fast electronics, combined with compressive sensing and quantum tomography algorithms, with the aim to reduce both the acquisition and the elaboration time by two orders of magnitude. Routes toward exploitation of the QPI devices will also be discussed.
- 12 July 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (14) , 6414
Open AccessTowards Quantum 3D Imaging Devices
We review the advancement of the research toward the design and implementation of quantum plenoptic cameras, radically novel 3D imaging devices that exploit both momentum–position entanglement and photon–number correlations to provide the typical refocusing and ultra-fast, scanning-free, 3D imaging capability of plenoptic devices, along with dramatically enhanced performances, unattainable in standard plenoptic cameras: diffraction-limited resolution, large depth of focus, and ultra-low noise. To further increase the volumetric resolution beyond the Rayleigh diffraction limit, and achieve the quantum limit, we are also developing dedicated protocols based on quantum Fisher information. However, for the quantum advantages of the proposed devices to be effective and appealing to end-users, two main challenges need to be tackled. First, due to the large number of frames required for correlation measurements to provide an acceptable signal-to-noise ratio, quantum plenoptic imaging (QPI) would require, if implemented with commercially available high-resolution cameras, acquisition times ranging from tens of seconds to a few minutes. Second, the elaboration of this large amount of data, in order to retrieve 3D images or refocusing 2D images, requires high-performance and time-consuming computation. To address these challenges, we are developing high-resolution single-photon avalanche photodiode (SPAD) arrays and high-performance low-level programming of ultra-fast electronics, combined with compressive sensing and quantum tomography algorithms, with the aim to reduce both the acquisition and the elaboration time by two orders of magnitude. Routes toward exploitation of the QPI devices will also be discussed.