Heating performance and indoor thermal environment analysis for an air source heat pump heating system with different heating terminals
Heating terminal configurations affect the operating performance and indoor thermal response of air source heat pumps (ASHPs) significantly. However, most studies have focused on steady heating conditions, with limited consideration of the frosting-defrosting process. Consequently, their effects during frosting-defrosting cycles remain unclear, hindering improvements in ASHP heating performance for different terminals. To address this issue, an ASHP test rig was established in an artificial environment chamber, in which fan coil units (FCUs) and radiant floors (RFs) were connected to the same ASHP unit and operated separately. Then, experiments were performed under preset environmental conditions to compare the frosting-defrosting characteristics, heating performance, and indoor thermal environment of the ASHP system under the FCU and RF heating modes. Results showed that the defrosting will cause obvious fluctuations in supply and return water temperatures under both the FCU and RF heating modes, and the former is more significant. Compared to those under the RF heating mode, the frosting suppression performance under the FCU heating mode was better, with frosting durations prolonged by 21.7% and 29.8%, respectively. However, better heating performance was obtained under the RF heating mode. The average heating capacity and COP under the RF heating mode were 7.9% and 21.3% higher than those under the FCU heating mode. In addition, the defrosting had less effect on indoor thermal environment under RF heating mode. The indoor temperature and relative humidity kept nearly constant under RF heating mode, while fluctuated 3.13–4.02 °C and 6.03%–7.51% under the FCU heating mode.
- 16 July 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessHeating performance and indoor thermal environment analysis for an air source heat pump heating system with different heating terminals
Heating terminal configurations affect the operating performance and indoor thermal response of air source heat pumps (ASHPs) significantly. However, most studies have focused on steady heating conditions, with limited consideration of the frosting-defrosting process. Consequently, their effects during frosting-defrosting cycles remain unclear, hindering improvements in ASHP heating performance for different terminals. To address this issue, an ASHP test rig was established in an artificial environment chamber, in which fan coil units (FCUs) and radiant floors (RFs) were connected to the same ASHP unit and operated separately. Then, experiments were performed under preset environmental conditions to compare the frosting-defrosting characteristics, heating performance, and indoor thermal environment of the ASHP system under the FCU and RF heating modes. Results showed that the defrosting will cause obvious fluctuations in supply and return water temperatures under both the FCU and RF heating modes, and the former is more significant. Compared to those under the RF heating mode, the frosting suppression performance under the FCU heating mode was better, with frosting durations prolonged by 21.7% and 29.8%, respectively. However, better heating performance was obtained under the RF heating mode. The average heating capacity and COP under the RF heating mode were 7.9% and 21.3% higher than those under the FCU heating mode. In addition, the defrosting had less effect on indoor thermal environment under RF heating mode. The indoor temperature and relative humidity kept nearly constant under RF heating mode, while fluctuated 3.13–4.02 °C and 6.03%–7.51% under the FCU heating mode.
- 11 March 2026
- Published by Elsevier in Journal of Building Engineering
- Vol. 123
Frosting loss assessment and design method for air source heat pumps using CICO-based equivalent temperature drop
- 11 March 2026
- Published by Elsevier in Journal of Building Engineering
- Vol. 123
Frosting loss assessment and design method for air source heat pumps using CICO-based equivalent temperature drop
- 10 March 2026
- Published by Elsevier in Solar Energy
- Vol. 310
Enhancing supply-demand matching in building energy system via optimal thermal-electric scheduling
- 10 March 2026
- Published by Elsevier in Solar Energy
- Vol. 310
Enhancing supply-demand matching in building energy system via optimal thermal-electric scheduling
- 20 January 2026
- Published by Elsevier in Journal of Building Engineering
- Vol. 119
A physics-based framework for quantifying building flexibility potential in demand response
- 20 January 2026
- Published by Elsevier in Journal of Building Engineering
- Vol. 119
A physics-based framework for quantifying building flexibility potential in demand response
- Top Cited Papers
Development of a universal frosting rate prediction model for optimizing the defrosting control strategy of air source heat pumps