AFAhmed E. Farghal

Ahmed E. Farghal

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ahmed E. Farghal has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    The Influence of Ferrule Design and Pulpal Extensions on the Accuracy of Fit and the Fracture Resistance of Zirconia-Reinforced Lithium Silicate Endocrowns

    by Samah Saker, Ahmed Yaseen Alqutaibi, Mohammed Ahmed Alghauli, Danya Hashem, Sary Borzangy, Ahmed E. Farghal, Ahmad A. Alnazzawi, Sultan Ainoosah, Mohammed H. AbdElaziz

    The study aimed to assess the marginal, axial, and internal adaptation, as well as the fracture resistance of zirconia-reinforced lithium silicate (ZLS) endocrowns with varying pulpal inlay extensions and marginal geometry. Sixty extracted maxillary first molar teeth were divided into six groups (n = 10) according to pulpal inlay extension and marginal configuration. The first three groups (J2, J3, and J4) utilized prepared teeth for endocrowns without ferrule design and 2 mm, 3 mm, and 4 mm pulpal extensions, respectively. The second three groups (F2, F3, and F4) utilized prepared teeth with 1 mm shoulder margins and 2 mm, 3 mm, and 4 mm pulpal extensions. The endocrowns were fabricated from ZLS blocks using CAD/CAM milling technology. After cementation, the specimens underwent thermal aging for 5000 cycles and were evaluated for marginal adaptation. Using a universal testing machine, the fracture resistance was tested under quasistatic loading (1 mm/min). Two-way ANOVA and the Tukey’s post hoc test were employed for data analysis (p ≤ 0.05). The results of this study revealed that endocrowns without ferrule exhibited superior fracture strength than a 1 mm ferrule design p < 0.05, irrespective of the inlay depth. All designs with and without ferrule and all inlay depths showed clinically acceptable marginal and internal fit. The conventional endocrown design without ferrule and 2 mm inlay depth showed the lowest surface gap. The pulpal surface showed the highest discrepancy among all groups compared to the other surfaces. Endocrowns without ferrule are more conservative and have higher fracture strength than 1 mm ferrule designs; extending the inlay depth showed a significant increase in fracture resistance of the 1 mm ferrule design, but not for the conventional design without ferrule and 2 mm inlay depth. All groups exhibited a high auspicious fracture strength value for molar endocrown restorations.


  • Open Access

    The Effectiveness of Cold Atmospheric Plasma (CAP) on Bacterial Reduction in Dental Implants: A Systematic Review

    by Ahmed Yaseen Alqutaibi, Abdulbari Aljohani, Abdullah Alduri, Abdulmajid Masoudi, Anas M. Alsaedi, Hesham Mohammed Al-Sharani, Ahmed E. Farghal, Ahmad Abdulkareem Alnazzawi, Afaf Noman Aboalrejal, Abdel-Aleam H. Mohamed, et al.

    Background: The emergence of dental implants has revolutionized the management of tooth loss. However, the placement of clinical implants exposes them to complex oral environment and numerous microscopic entities, such as bacteria. Cold atmospheric plasma (CAP) is often used to treat the surfaces of dental implants, which alters morphological features and effectively reduces bacterial load. Purpose: This systematic review aims to assess the existing literature on the bactericidal properties of CAP when used on various kinds of dental implant surfaces. Review Method: An in-depth examination of MEDLINE/PubMed and EMBASE was performed to identify relevant studies, with the most recent search conducted in May 2023. Studies were selected based on their exploration of CAP’s effects on dental implants compared to control groups, focusing on CAP’s bactericidal efficacy. However, studies that lacked a control group or that failed to measure bactericidal effects were excluded. Results: After applying the selection criteria, 15 studies were ultimately included in the systematic review. The collected data suggest that CAP can effectively reduce bacterial loads on dental implant surfaces, including pathogens like Streptococcus mitis and Staphylococcus aureus. Furthermore, CAP appears to combat biofilms and plaques that are key contributors to periimplantitis. Conclusion: CAP emerges as a promising treatment option, exhibiting significant bactericidal activity on dental implant surfaces. CAP can decrease the rates of bacterial biofilm and plaque formation, leading to improved outcomes for dental implant patients.


  • Top Cited Papers
    Open Access

    Polymeric Denture Base Materials: A Review

    by Ahmed Yaseen Alqutaibi, Abdulmajeed Baik, Sarah A. Almuzaini, Ahmed E. Farghal, Ahmad Abdulkareem Alnazzawi, Sary Borzangy, Afaf Noman Aboalrejal, Mohammed Hosny AbdElaziz, Ihab Ismail Mahmoud, Muhammad Sohail Zafar

    An ideal denture base must have good physical and mechanical properties, biocompatibility, and esthetic properties. Various polymeric materials have been used to construct denture bases. Polymethyl methacrylate (PMMA) is the most used biomaterial for dentures fabrication due to its favorable properties, which include ease of processing and pigmenting, sufficient mechanical properties, economy, and low toxicity. This article aimed to comprehensively review the current knowledge about denture base materials (DBMs) types, properties, modifications, applications, and construction methods. We searched for articles about denture base materials in PubMed, Scopus, and Embase. Journals covering topics including dental materials, prosthodontics, and restorative dentistry were also combed through. Denture base material variations, types, qualities, applications, and fabrication research published in English were considered. Although PMMA has several benefits and gained popularity as a denture base material, it has certain limitations and cannot be classified as an ideal biomaterial for fabricating dental prostheses. Accordingly, several studies have been performed to enhance the physical and mechanical properties of PMMA by chemical modifications and mechanical reinforcement using fibers, nanofillers, and hybrid materials. This review aimed to update the current knowledge about DBMs’ types, properties, applications, and recent developments. There is a need for specific research to improve their biological properties due to patient and dental staff adverse reactions to possibly harmful substances produced during their manufacturing and use.


  • Open Access

    Impact of Acrylic and Silicone-Based Soft-Liner Materials on Biting Force and Quality of Life of the Complete Denture Wearers: A Randomized Clinical Trial

    by Ahmed Yaseen Alqutaibi, Ahmad A. Alnazzawi, Ahmed E. Farghal, Ramy M. Bakr, Ihab Ismail Mahmoud

    This rerandomized clinical trial evaluated the influence of soft liners (SL) on biting force, pain perception, and the oral health-related quality of life (OHRQoL) of complete denture wearers. Twenty-eight completely edentulous patients complaining of ill-fitting lower complete dentures were selected to participate in the study from the Dental Hospital, College of Dentistry, Taibah University. All patients received new complete maxillary and mandibular dentures; then they were randomly divided into two groups (14 patients in each group): the acrylic-based SL group, in which the mandibular denture was lined with an acrylic-based soft liner, and the silicone-based SL group, in which the mandibular denture was lined with a silicone-based soft liner. OHRQoL and maximum bite force (MBF) were assessed in this study before denture relining (baseline), then at one month and three months after relining. The finding showed that both treatment modalities significantly improved the OHRQoL of included patients at one-month and three-month periods compared to baseline records (i.e., dentures before relining) with a statistically significant difference (p < 0.05). However, there is no statistical difference between groups at the baseline, one-, and three-month follow-up periods. Regarding maximum biting force, when acrylic-based SL is compared to silicone-based SL, there is no statistical difference between groups at baseline (75 ± 31 and 83 ± 32 N) and one-month follow-up periods (145 ± 53 and 156 ± 49 N); however, after three months of function, the silicone-based group recorded 166 ± 57 N statistically significant high biting force compared to the acrylic-based group that recorded 116 ± 47 N (p < 0.05). Permanent soft denture liners positively affect maximum biting force, pain perception, and OHRQoL more than conventional dentures. After three months, silicone-based SL outperformed acrylic-based soft liners in maximum biting force, which may indicate better long-term results.