Renato Sussumu Dds Nishioka
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Renato Sussumu Dds Nishioka has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Alberto Noriyuki Dds Kojima
Professor, Department of Dental Materials and Prosthesis, São Paulo State University, ICT, UNESP, São José dos Campos, São Paulo, Brazil
1 shared publication- Alexandre Luiz Souto Borges
Department of Dental Materials and Prosthodontics, Institute of Science and Technology, São Paulo State University (UNESP), São José dos Campos 12245-000, SP, Brazil
1 shared publication Dimas Rennó de Lima
Assistant Professor, Department of Dental Material and Prosthodontics, Univ. Estadual Paulista-UNESP-Institute of Science and Technology, São José dos Campos/SP, Brasil
1 shared publication- Francisley Ávila Souza
Department of Diagnosis and Surgery, School of Dentistry, São Paulo State University (UNESP), Araçatuba 16015-050, SP, Brazil
1 shared publication Gabriela Nogueira Dds De Melo Nishioka
PhD Student, Department of Dental Materials and Prosthesis, São Paulo State University, ICT, UNESP, São José dos Campos, São Paulo, Brazil
1 shared publication- João Paulo Mendes Tribst
Department of Reconstructive Oral Care, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam, and Vrije Universiteit Amsterdam, 1081 LA Amsterdam, North Holland, The Netherlands
1 shared publication
Latest Publications
- 1 April 2018
- Published by Wolters Kluwer Health in Implant Dentistry
- Vol. 27 (2) , 188-192
Strain Gauge Evaluation of Transfer Impression Techniques of Multiple Implant-Supported Prosthesis
Purpose: This in vitro study assessed the accuracy of multiple implant-level impression techniques (open tray and closed tray) for the fabrication of 3-unit implant prostheses with strain gauge (SG) analysis. Materials and Methods: A polyurethane master model was designed to simulate a clinical situation. Two rigid custom trays were fabricated for the model. The impression material used was polysulfide. Transfer implant impressions were made using 2 techniques; ten tapered copings not splinted (custom closed tray) and ten square copings splinted with acrylic-resin (custom open tray). The improved stone models were allowed to set for 1 hour before being separated from the impression. The superstructures were sprued, invested, and cast with a cobalt-chromium alloy. Four SGs were bonded on the surface of each polyurethane block. Results: A statistically significant difference was found between the 2 impression techniques tested (P = 0.000). This study found a significant average difference of 144.68 ± 5.53 με for open custom tray and 253.3 ± 16.7 με for closed custom tray. Conclusion: The custom open tray technique was the most accurate impression for multiple implants compared with closed custom tray.
- 1 April 2018
- Published by Wolters Kluwer Health in Implant Dentistry
- Vol. 27 (2) , 188-192
Strain Gauge Evaluation of Transfer Impression Techniques of Multiple Implant-Supported Prosthesis
Purpose: This in vitro study assessed the accuracy of multiple implant-level impression techniques (open tray and closed tray) for the fabrication of 3-unit implant prostheses with strain gauge (SG) analysis. Materials and Methods: A polyurethane master model was designed to simulate a clinical situation. Two rigid custom trays were fabricated for the model. The impression material used was polysulfide. Transfer implant impressions were made using 2 techniques; ten tapered copings not splinted (custom closed tray) and ten square copings splinted with acrylic-resin (custom open tray). The improved stone models were allowed to set for 1 hour before being separated from the impression. The superstructures were sprued, invested, and cast with a cobalt-chromium alloy. Four SGs were bonded on the surface of each polyurethane block. Results: A statistically significant difference was found between the 2 impression techniques tested (P = 0.000). This study found a significant average difference of 144.68 ± 5.53 με for open custom tray and 253.3 ± 16.7 με for closed custom tray. Conclusion: The custom open tray technique was the most accurate impression for multiple implants compared with closed custom tray.
- 1 February 2018
- Published by Wolters Kluwer Health in Implant Dentistry
- Vol. 27 (1) , 49-55
Validation of a Simplified Implant-Retained Cantilever Fixed Prosthesis
Purpose: To evaluate the stress and strain generated in a fixed four-element prosthesis under the application of axial and nonaxial loads using a simplified implant-supported fixed prosthesis model. Materials and Methods: A 3-dimensional model was constructed containing 3 implants with a conventional anatomical prosthesis (G1). The second model with the same implant system received the simplified prosthesis (G2). A load of 300 N was applied at an axial point and a nonaxial point through finite element analysis software. Results: The G2 group showed different values of stress concentration in the prosthesis, fixation screw, retention screw, and abutments when compared with G1. Within a limit of 10% degrees of acceptability, the stress on the implants and the bone strain were enclosed for both models of prostheses. Conclusion: The simplified fixed prosthesis evaluated presents biomechanical behavior similar to an anatomical prosthesis in the implants and in the surrounding bone structure.
- 1 February 2018
- Published by Wolters Kluwer Health in Implant Dentistry
- Vol. 27 (1) , 49-55
Validation of a Simplified Implant-Retained Cantilever Fixed Prosthesis
Purpose: To evaluate the stress and strain generated in a fixed four-element prosthesis under the application of axial and nonaxial loads using a simplified implant-supported fixed prosthesis model. Materials and Methods: A 3-dimensional model was constructed containing 3 implants with a conventional anatomical prosthesis (G1). The second model with the same implant system received the simplified prosthesis (G2). A load of 300 N was applied at an axial point and a nonaxial point through finite element analysis software. Results: The G2 group showed different values of stress concentration in the prosthesis, fixation screw, retention screw, and abutments when compared with G1. Within a limit of 10% degrees of acceptability, the stress on the implants and the bone strain were enclosed for both models of prostheses. Conclusion: The simplified fixed prosthesis evaluated presents biomechanical behavior similar to an anatomical prosthesis in the implants and in the surrounding bone structure.