RNRenato Sussumu Dds Nishioka

Renato Sussumu Dds Nishioka

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Renato Sussumu Dds Nishioka has a total of 8 co-authors. Here are the top co-authors by number of shared publications:

  • Alberto Noriyuki Dds Kojima

    Professor, Department of Dental Materials and Prosthesis, São Paulo State University, ICT, UNESP, São José dos Campos, São Paulo, Brazil

    1 shared publication
  • Alexandre Luiz Souto Borges

    Department of Dental Materials and Prosthodontics, Institute of Science and Technology, São Paulo State University (UNESP), São José dos Campos 12245-000, SP, Brazil

    1 shared publication
  • Dimas Rennó de Lima

    Assistant Professor, Department of Dental Material and Prosthodontics, Univ. Estadual Paulista-UNESP-Institute of Science and Technology, São José dos Campos/SP, Brasil

    1 shared publication
  • Francisley Ávila Souza

    Department of Diagnosis and Surgery, School of Dentistry, São Paulo State University (UNESP), Araçatuba 16015-050, SP, Brazil

    1 shared publication
  • Gabriela Nogueira Dds De Melo Nishioka

    PhD Student, Department of Dental Materials and Prosthesis, São Paulo State University, ICT, UNESP, São José dos Campos, São Paulo, Brazil

    1 shared publication
  • João Paulo Mendes Tribst

    Department of Reconstructive Oral Care, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam, and Vrije Universiteit Amsterdam, 1081 LA Amsterdam, North Holland, The Netherlands

    1 shared publication

Latest Publications

  • Strain Gauge Evaluation of Transfer Impression Techniques of Multiple Implant-Supported Prosthesis

    by Renato Sussumu Dds Nishioka, Leandro Ruivo Dds De Santis, Gabriela Nogueira Dds De Melo Nishioka, Alberto Noriyuki Dds Kojima, Francisley Ávila Dds Souza

    Purpose: This in vitro study assessed the accuracy of multiple implant-level impression techniques (open tray and closed tray) for the fabrication of 3-unit implant prostheses with strain gauge (SG) analysis. Materials and Methods: A polyurethane master model was designed to simulate a clinical situation. Two rigid custom trays were fabricated for the model. The impression material used was polysulfide. Transfer implant impressions were made using 2 techniques; ten tapered copings not splinted (custom closed tray) and ten square copings splinted with acrylic-resin (custom open tray). The improved stone models were allowed to set for 1 hour before being separated from the impression. The superstructures were sprued, invested, and cast with a cobalt-chromium alloy. Four SGs were bonded on the surface of each polyurethane block. Results: A statistically significant difference was found between the 2 impression techniques tested (P = 0.000). This study found a significant average difference of 144.68 ± 5.53 με for open custom tray and 253.3 ± 16.7 με for closed custom tray. Conclusion: The custom open tray technique was the most accurate impression for multiple implants compared with closed custom tray.


  • Validation of a Simplified Implant-Retained Cantilever Fixed Prosthesis

    by João Paulo Mendes Dds Tribst, Vinícius Anéas Dds Rodrigues, Alexandre Luiz Souto Dds Borges, Dimas Rennó de Lima, Renato Sussumu Dds Nishioka

    Purpose: To evaluate the stress and strain generated in a fixed four-element prosthesis under the application of axial and nonaxial loads using a simplified implant-supported fixed prosthesis model. Materials and Methods: A 3-dimensional model was constructed containing 3 implants with a conventional anatomical prosthesis (G1). The second model with the same implant system received the simplified prosthesis (G2). A load of 300 N was applied at an axial point and a nonaxial point through finite element analysis software. Results: The G2 group showed different values of stress concentration in the prosthesis, fixation screw, retention screw, and abutments when compared with G1. Within a limit of 10% degrees of acceptability, the stress on the implants and the bone strain were enclosed for both models of prostheses. Conclusion: The simplified fixed prosthesis evaluated presents biomechanical behavior similar to an anatomical prosthesis in the implants and in the surrounding bone structure.