Shifeng Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Shifeng Zhang has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Min Zhang
State Grid Shanxi Electric Power Company Electric Power Research Institute, Taiyuan 030001, China
3 shared publications - Le Gao
State Grid Shanxi Electric Power Company Electric Power Research Institute, Taiyuan 030001, China
2 shared publications Chang Xiao
Electric Power Research Institute, State Grid Shanxi Electric Power Company Shanxi China
1 shared publication- Hongmin Yao
State Grid Shanxi Electric Power Company Electric Power Research Institute, Taiyuan 030001, China
1 shared publication - Jinhao Wang
Electric Power Research Institute of State Grid Shanxi Electirc Power Company, Taiyuan 030001, China
1 shared publication Lei Da
Electric Power Research Institute, State Grid Shanxi Electric Power Company Shanxi China
1 shared publication
Latest Publications
- Open Access
Steady-State Analysis of Voltage Deviations and Three-Phase Imbalance in Distribution Networks Considering Spatiotemporal Coupling of Source-Load Uncertainties
To address the deep spatiotemporal coupling of source-load dual uncertainties attributed to the high penetration of distributed photovoltaics (PVs) and electric vehicles (EVs) into distribution grids, and the difficulty of analyzing composite disturbances using traditional methods, this paper proposes a voltage quality analysis method that considers spatiotemporal coupling of source-load uncertainty, focusing on steady-state voltage deviation and three-phase imbalance problems. First, a probabilistic model of PV generation is constructed using the beta distribution combined with Monte Carlo-based scenario reduction, and high-precision forecasting of EV charging loads is achieved by an attention-based convolutional neural network and long short-term memory network. Second, multi-scenario spatiotemporal power flow calculations are conducted on the distribution network to analyze the complementary effects of voltage deviation and three-phase imbalance under the hybrid integration of PV and EV. Finally, gray wolf optimization-based variational mode decomposition is introduced to adaptively decompose the source-load power. This reveals the intrinsic mechanisms where low-frequency components dominate the fundamental amplitude variations of bus voltages, while high-frequency components exert a significant impact on voltage quality. Simulation results demonstrate that the proposed method can effectively analyze the spatiotemporal coupling of source-load uncertainties, providing technical support for the comprehensive management of voltage quality in distribution networks.
Open AccessSteady-State Analysis of Voltage Deviations and Three-Phase Imbalance in Distribution Networks Considering Spatiotemporal Coupling of Source-Load Uncertainties
To address the deep spatiotemporal coupling of source-load dual uncertainties attributed to the high penetration of distributed photovoltaics (PVs) and electric vehicles (EVs) into distribution grids, and the difficulty of analyzing composite disturbances using traditional methods, this paper proposes a voltage quality analysis method that considers spatiotemporal coupling of source-load uncertainty, focusing on steady-state voltage deviation and three-phase imbalance problems. First, a probabilistic model of PV generation is constructed using the beta distribution combined with Monte Carlo-based scenario reduction, and high-precision forecasting of EV charging loads is achieved by an attention-based convolutional neural network and long short-term memory network. Second, multi-scenario spatiotemporal power flow calculations are conducted on the distribution network to analyze the complementary effects of voltage deviation and three-phase imbalance under the hybrid integration of PV and EV. Finally, gray wolf optimization-based variational mode decomposition is introduced to adaptively decompose the source-load power. This reveals the intrinsic mechanisms where low-frequency components dominate the fundamental amplitude variations of bus voltages, while high-frequency components exert a significant impact on voltage quality. Simulation results demonstrate that the proposed method can effectively analyze the spatiotemporal coupling of source-load uncertainties, providing technical support for the comprehensive management of voltage quality in distribution networks.
- Open Access
Power Quality Improvement Strategy Based on Grid-Forming Control and Consensus Algorithm
With the integration of high-penetration distributed renewable energy sources and grid-forming inverters, AC microgrids face significant challenges in maintaining autonomous voltage and frequency stability. While traditional droop control can achieve autonomous power allocation, it introduces inherent steady-state deviations when load change. To address this, this paper proposes a distributed secondary control strategy for AC microgrids based on a consensus algorithm, aiming to achieve high-precision coordinated correction of voltage and frequency and improve power quality. In the proposed strategy, each grid-forming inverter autonomously generates dynamic secondary compensation signals based solely on local measurements and limited information exchange with neighboring nodes, eliminating the need for a central controller and enhancing robustness, scalability, and fault tolerance. Stability is proven via Lyapunov function construction. Simulation results show that the strategy effectively eliminates steady-state errors, with frequency deviations within ±0.01 Hz and voltage deviations below 0.5% of the rated value. Rapid and precise regulation is achieved under various load disturbances and network conditions, validating its effectiveness and application potential.
Open AccessPower Quality Improvement Strategy Based on Grid-Forming Control and Consensus Algorithm
With the integration of high-penetration distributed renewable energy sources and grid-forming inverters, AC microgrids face significant challenges in maintaining autonomous voltage and frequency stability. While traditional droop control can achieve autonomous power allocation, it introduces inherent steady-state deviations when load change. To address this, this paper proposes a distributed secondary control strategy for AC microgrids based on a consensus algorithm, aiming to achieve high-precision coordinated correction of voltage and frequency and improve power quality. In the proposed strategy, each grid-forming inverter autonomously generates dynamic secondary compensation signals based solely on local measurements and limited information exchange with neighboring nodes, eliminating the need for a central controller and enhancing robustness, scalability, and fault tolerance. Stability is proven via Lyapunov function construction. Simulation results show that the strategy effectively eliminates steady-state errors, with frequency deviations within ±0.01 Hz and voltage deviations below 0.5% of the rated value. Rapid and precise regulation is achieved under various load disturbances and network conditions, validating its effectiveness and application potential.
- Open Access
- 31 August 2023
- Published by MDPI AG in Electronics
- Vol. 12 (17) , 3684
Harmonic Resonance Analysis and Impedance Remodeling Method of Multi-Inverter Grid-Connected System
The harmonic and resonant characteristics of a multi-inverter grid-connected system can negatively affect power quality when weak grid conditions are present. In this paper, firstly, harmonic currents are modeled for the inverter, the correctness of low-frequency harmonics and high-frequency harmonics are verified in closed loop, and the characteristics of harmonic currents are analyzed when the parameters are varied. Secondly, the resonant characteristics of the inverter with feed-forward link are analyzed, and a multi-inverter grid-connected equivalent model based on the triple-decomposition conductance is developed and analyzed in conjunction with the resonant modal analysis method. Then, a harmonic resonance impedance reshaping method is proposed to suppress the background harmonics using improved weighted average current control (WACC), suppress the system resonance based on the point of common coupling (PCC) paralleling virtual conductance method, and improve the stability margin of the system combined with impedance reshaping resonance suppression method. Finally, simulations and comparison of results with different suppression methods verify the superiority and effectiveness of the proposed method.
- 31 August 2023
- Published by MDPI AG in Electronics
- Vol. 12 (17) , 3684
Open AccessHarmonic Resonance Analysis and Impedance Remodeling Method of Multi-Inverter Grid-Connected System
The harmonic and resonant characteristics of a multi-inverter grid-connected system can negatively affect power quality when weak grid conditions are present. In this paper, firstly, harmonic currents are modeled for the inverter, the correctness of low-frequency harmonics and high-frequency harmonics are verified in closed loop, and the characteristics of harmonic currents are analyzed when the parameters are varied. Secondly, the resonant characteristics of the inverter with feed-forward link are analyzed, and a multi-inverter grid-connected equivalent model based on the triple-decomposition conductance is developed and analyzed in conjunction with the resonant modal analysis method. Then, a harmonic resonance impedance reshaping method is proposed to suppress the background harmonics using improved weighted average current control (WACC), suppress the system resonance based on the point of common coupling (PCC) paralleling virtual conductance method, and improve the stability margin of the system combined with impedance reshaping resonance suppression method. Finally, simulations and comparison of results with different suppression methods verify the superiority and effectiveness of the proposed method.
- Open Access
- 5 January 2017
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2017 (13) , 996-1001
Two harmonic analysis of short circuit current in wind farm
With the increase of capacity and the improvement of economy, doubly‐fed induction generator (DFIG) is gradually becoming the most widely used wind power generator in the world. DFIG has different characteristics of transient operation from the synchronous generator and its short‐circuit current is affected by the converter control mode, thus when there is a voltage sags occurs, the short‐circuit current of the wind farm may contain a certain amount of two harmonic. Power transformer is one of the most important power equipment in power system and the normal or not of transformer protection determines the safe and stable operation of power system. At present, the main protection of transformer is longitudinal differential protection. In order to correctly identify the inrush current, it is usually equipped with two harmonic braking measures to ensure the reliable operation of differential protection. Therefore, when the transformer failure occurs in wind farm, the protection may refuse to operate due to the reason that the short‐circuit current contains a certain amount of two harmonic. Focused on the large‐scale application of DFIG and the lack of the short‐circuit current harmonic characteristics analysis, this work is devoted to the study of two harmonic characteristics and their influence on transformer protection when the grid voltage occurs in a non‐depth drop. Through the analysis of the short‐circuit current, harmonic components under different control modes of converter research the characteristics and production mechanism of the two harmonic currents of the doubly‐fed wind power generator. This also lays a solid foundation for the improvement of transformer protection. Finally, the correctness of the analysis is verified by the experiments of short‐circuit and time‐domain simulation.
- 5 January 2017
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2017 (13) , 996-1001
Open AccessTwo harmonic analysis of short circuit current in wind farm
With the increase of capacity and the improvement of economy, doubly‐fed induction generator (DFIG) is gradually becoming the most widely used wind power generator in the world. DFIG has different characteristics of transient operation from the synchronous generator and its short‐circuit current is affected by the converter control mode, thus when there is a voltage sags occurs, the short‐circuit current of the wind farm may contain a certain amount of two harmonic. Power transformer is one of the most important power equipment in power system and the normal or not of transformer protection determines the safe and stable operation of power system. At present, the main protection of transformer is longitudinal differential protection. In order to correctly identify the inrush current, it is usually equipped with two harmonic braking measures to ensure the reliable operation of differential protection. Therefore, when the transformer failure occurs in wind farm, the protection may refuse to operate due to the reason that the short‐circuit current contains a certain amount of two harmonic. Focused on the large‐scale application of DFIG and the lack of the short‐circuit current harmonic characteristics analysis, this work is devoted to the study of two harmonic characteristics and their influence on transformer protection when the grid voltage occurs in a non‐depth drop. Through the analysis of the short‐circuit current, harmonic components under different control modes of converter research the characteristics and production mechanism of the two harmonic currents of the doubly‐fed wind power generator. This also lays a solid foundation for the improvement of transformer protection. Finally, the correctness of the analysis is verified by the experiments of short‐circuit and time‐domain simulation.