M. Arif
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
M. Arif has a total of 2 co-authors. Here are the top co-authors by number of shared publications:
- Shahzad Ahmad Qureshi
Department of Computer and Information Sciences, Pakistan Institute of Engineering and Applied Sciences (PIEAS), Islamabad 45650, Pakistan
2 shared publications - Sikander M. Mirza
Department of Physics and Applied Mathematics, Pakistan Institute of Engineering and Applied Sciences (PIEAS), Islamabad, Pakistan
2 shared publications
Latest Publications
- 1 December 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
A Template Based Continuous Genetic Algorithm for Image Reconstruction
A template-based continuous genetic algorithm (CGA) image reconstruction methodology is proposed for tomographic image reconstruction. For the head and the lung phantoms, the proposed methodology has been found to yield higher image-quality in comparison with the conventional techniques including back-projection, filtered-back-projection, and simulated annealing techniques. Sensitivity of image-quality measures on various crossover operators including uniform, image-row, and block crossover operators has been studied and the image-row crossover has been found to yield the highest PSNR value at large values of crossover probabilities. The CGA, in terms of the PSNR values, has shown about 80% improvement compared with FBP for both head as well as lung phantoms and about 11% in the case of SA for 32 times 32 head phantom.
- 1 December 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
A Template Based Continuous Genetic Algorithm for Image Reconstruction
A template-based continuous genetic algorithm (CGA) image reconstruction methodology is proposed for tomographic image reconstruction. For the head and the lung phantoms, the proposed methodology has been found to yield higher image-quality in comparison with the conventional techniques including back-projection, filtered-back-projection, and simulated annealing techniques. Sensitivity of image-quality measures on various crossover operators including uniform, image-row, and block crossover operators has been studied and the image-row crossover has been found to yield the highest PSNR value at large values of crossover probabilities. The CGA, in terms of the PSNR values, has shown about 80% improvement compared with FBP for both head as well as lung phantoms and about 11% in the case of SA for 32 times 32 head phantom.
- 1 August 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-8
Inverse Radon Transform-Based Image Reconstruction using Various Frequency Domain Filters in Parallel Beam Transmission Tomography
Inverse Radon transform based image reconstruction is of prime importance in various areas of science and engineering. Over the years, many techniques have emerged as possible alternative to exact analytical solution including back-projection (BP) and filtered back-projection (FBP). In FBP various filters are applied namely Ram-Lak (ramp), Shepp-Logan, Cosine, Hamming and Hanning filters. These techniques are applied to the head phantom and the lung phantom. Best results as reconstructed image are obtained by FBP technique using Hanning filter, which is in agreement with findings of other researchers. Additionally, FBP technique using Hamming filter has been found as effective as FBP Hanning filter technique in both cases.
- 1 August 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-8
Inverse Radon Transform-Based Image Reconstruction using Various Frequency Domain Filters in Parallel Beam Transmission Tomography
Inverse Radon transform based image reconstruction is of prime importance in various areas of science and engineering. Over the years, many techniques have emerged as possible alternative to exact analytical solution including back-projection (BP) and filtered back-projection (FBP). In FBP various filters are applied namely Ram-Lak (ramp), Shepp-Logan, Cosine, Hamming and Hanning filters. These techniques are applied to the head phantom and the lung phantom. Best results as reconstructed image are obtained by FBP technique using Hanning filter, which is in agreement with findings of other researchers. Additionally, FBP technique using Hamming filter has been found as effective as FBP Hanning filter technique in both cases.