Mehrzad Gholampour Dehaki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mehrzad Gholampour Dehaki has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Farnoosh Hoseinpour
Operative Department, Tehran University of Medical Science, Tehran, Iran
1 shared publicationHooman Ebrahimi
Laser Research Center, School of Dentistry, Tehran University Of Medical Sciences, International Campus, Tehran, Iran
1 shared publication- Ladan Ranjbar Omrani
Department of Restorative Dentistry, Dental School, Tehran University of Medical Sciences, Tehran, Iran
1 shared publication - Mahdi Mohebbi
Valiasr Hospital, Abadan University of Medical Sciences, Khoramshahr
1 shared publication - Mahsa Mozaffari
Department of Pediatrics, Iran University of Medical Sciences, Tehran, Iran
1 shared publication Masoome Hasanitabatabaee
Operative Department, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran
1 shared publication
Latest Publications
- Open Access
- 1 February 2020
- Published by Georg Thieme Verlag KG in European Journal of Dentistry
- Vol. 14 (01) , 085-091
Effect of an Optical Whitening Toothpaste on Color Stability of Tooth-Colored Restorative Materials
Objectives This study aimed to assess the effect of an optical whitening toothpaste on color stability of microhybrid, nanofilled, and microfilled composite resins and resin-modified glass ionomer (RMGI) cement in comparison of two other toothpastes. Materials and Methods In this experimental study, disc-shaped composite samples were fabricated. The samples were then polished using silicon carbide papers. Twenty-seven samples of each material were fabricated and subjected to colorimetry using a spectrophotometer. Each group of material was then divided into three subgroups for the application of conventional whitening and whitening containing blue covarine toothpastes. One operator brushed the samples with an electric soft toothbrush with circular motion twice a day, each time for 30 seconds. Colorimetry was performed at 0, 1, 7, 30, and 90 days. Statistical Analysis Two-way analysis of variance (ANOVA), one-way ANOVA, and Tukey’s honestly significant difference (HSD) test were used for statistical analysis. Results The interaction effect of type of restorative material and time on ∆E was not significant at baseline or 1 day (p > 0.05). The effect of type of toothpaste on ∆E was not significant at baseline or 1 day (p = 0.78) but the effect of type of material was significant (p < 0.05). The toothpastes had significantly different effects on ∆E of Z250 at all time points (p < 0.05) except for ∆E0–30 (p = 0.106). The toothpastes had significantly different effects on ∆E of Z350 and Gradia at all time points (p < 0.05). The same was true for RMGI except for ∆E0–7 (p = 0.43) and ∆E0–90 (p = 0.52). The majority of color changes caused by toothpastes were not clinically perceivable (∆E < 3.3), except for ∆E0–90 by the whitening toothpaste (∆E = 9), ∆E0–90 by the conventional toothpaste for Z350 (∆E = 3.9), and ∆E0–1 by the whitening toothpaste for RMGI (∆E = 3.7). Conclusion The color change of all composite samples was not clinically perceivable (<3.3) at all time points, which shows that the tested toothpastes do not cause a significant change in color of composite materials.
- 1 February 2020
- Published by Georg Thieme Verlag KG in European Journal of Dentistry
- Vol. 14 (01) , 085-091
Open AccessEffect of an Optical Whitening Toothpaste on Color Stability of Tooth-Colored Restorative Materials
Objectives This study aimed to assess the effect of an optical whitening toothpaste on color stability of microhybrid, nanofilled, and microfilled composite resins and resin-modified glass ionomer (RMGI) cement in comparison of two other toothpastes. Materials and Methods In this experimental study, disc-shaped composite samples were fabricated. The samples were then polished using silicon carbide papers. Twenty-seven samples of each material were fabricated and subjected to colorimetry using a spectrophotometer. Each group of material was then divided into three subgroups for the application of conventional whitening and whitening containing blue covarine toothpastes. One operator brushed the samples with an electric soft toothbrush with circular motion twice a day, each time for 30 seconds. Colorimetry was performed at 0, 1, 7, 30, and 90 days. Statistical Analysis Two-way analysis of variance (ANOVA), one-way ANOVA, and Tukey’s honestly significant difference (HSD) test were used for statistical analysis. Results The interaction effect of type of restorative material and time on ∆E was not significant at baseline or 1 day (p > 0.05). The effect of type of toothpaste on ∆E was not significant at baseline or 1 day (p = 0.78) but the effect of type of material was significant (p < 0.05). The toothpastes had significantly different effects on ∆E of Z250 at all time points (p < 0.05) except for ∆E0–30 (p = 0.106). The toothpastes had significantly different effects on ∆E of Z350 and Gradia at all time points (p < 0.05). The same was true for RMGI except for ∆E0–7 (p = 0.43) and ∆E0–90 (p = 0.52). The majority of color changes caused by toothpastes were not clinically perceivable (∆E < 3.3), except for ∆E0–90 by the whitening toothpaste (∆E = 9), ∆E0–90 by the conventional toothpaste for Z350 (∆E = 3.9), and ∆E0–1 by the whitening toothpaste for RMGI (∆E = 3.7). Conclusion The color change of all composite samples was not clinically perceivable (<3.3) at all time points, which shows that the tested toothpastes do not cause a significant change in color of composite materials.
- Open Access
- 2 August 2019
- Published by PAGEPress Publications in European Journal of Translational Myology
- Vol. 29 (3) , 261-267
Comparison between ultrasonographic findings and fine needle aspiration cytology in differentiating malignant and benign thyroid nodules
The purpose of research was comparing the ultrasound (US) features and fine-needle aspiration cytology (FNAC) in detecting the thyroid nodules in clinical practice. A cross-sectional analytical study retrospectively reviewed the US and FNAC findings for a total of 170 thyroid nodules. The US features that we compared included echogenicity, calcifications, shape, halo and Doppler, between 2017 and 2018. Totally, 170 nodules of thyroid were studied, which contained 72 (42.4%) benign and 98 (57.6%) malignant thyroid nodules. The sonographic features were significantly associated with malignancy such as microcalcification (97.0%), hyperechogenicity (91.5%), wider than taller shape (98.0%), absent halo (90.9%) and positive Doppler (78.0%) (P < 0.01). The altogether accuracies of calcification, echogenicity, shape, halo, and Doppler were 0.96, 0.92, 0.97,0.82 and 0.82, respectively. Our data suggest that US features could be a good sonographic criterion for recommending FNA cytology with follow‐up thyroid sonography and FNA.
- 2 August 2019
- Published by PAGEPress Publications in European Journal of Translational Myology
- Vol. 29 (3) , 261-267
Open AccessComparison between ultrasonographic findings and fine needle aspiration cytology in differentiating malignant and benign thyroid nodules
The purpose of research was comparing the ultrasound (US) features and fine-needle aspiration cytology (FNAC) in detecting the thyroid nodules in clinical practice. A cross-sectional analytical study retrospectively reviewed the US and FNAC findings for a total of 170 thyroid nodules. The US features that we compared included echogenicity, calcifications, shape, halo and Doppler, between 2017 and 2018. Totally, 170 nodules of thyroid were studied, which contained 72 (42.4%) benign and 98 (57.6%) malignant thyroid nodules. The sonographic features were significantly associated with malignancy such as microcalcification (97.0%), hyperechogenicity (91.5%), wider than taller shape (98.0%), absent halo (90.9%) and positive Doppler (78.0%) (P < 0.01). The altogether accuracies of calcification, echogenicity, shape, halo, and Doppler were 0.96, 0.92, 0.97,0.82 and 0.82, respectively. Our data suggest that US features could be a good sonographic criterion for recommending FNA cytology with follow‐up thyroid sonography and FNA.
- Open Access
- 26 December 2017
- Published by Maad Rayan Publishing Company in Journal of lasers in medical sciences
- Vol. 9 (1) , 36-42
Bond Strength of Fiber Posts to Composite Core: Effect of Surface Treatment With Er,Cr:YSGG Laser and Thermocycling
Bond Strength of Fiber Posts to Composite Core: Effect of Surface Treatment With Er,Cr:YSGG Laser and Thermocycling
- 26 December 2017
- Published by Maad Rayan Publishing Company in Journal of lasers in medical sciences
- Vol. 9 (1) , 36-42
Open AccessBond Strength of Fiber Posts to Composite Core: Effect of Surface Treatment With Er,Cr:YSGG Laser and Thermocycling
Bond Strength of Fiber Posts to Composite Core: Effect of Surface Treatment With Er,Cr:YSGG Laser and Thermocycling