Fengfeng Shu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Fengfeng Shu has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Yihui Wu
Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences
5 shared publications - Huan Li
Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China
3 shared publications - Xiao Lv
Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China
3 shared publications - Zihan Song
Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China
3 shared publications - Ming Gao
Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China
2 shared publications - Shixun Zhao
Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China
2 shared publications
Latest Publications
- Open Access
- 13 March 2025
- Published by MDPI AG in Micromachines
- Vol. 16 (3) , 332
Efficient Particle Capture and Release Method for DNA Library Preparation on Microfluidics
To address the issues of agglomeration during magnetic particle capture and the incomplete release of these particles during reuse in microfluidic chips for library preparation, a microchamber was utilized to enhance the dispersion area for magnetic particle capture. Additionally, the release of magnetic particles was achieved through the synergistic action of flow field and magnetic field. The simulation results indicated that as the inlet flow velocity varied from 0.02 m/s to 0.16 m/s and the magnet spacing ranged from 1.2 mm to 1.8 mm, the coverage of magnetic particles in the microchamber increased from 17.29% to 63.59%. Meanwhile, the magnetic particle capture rate decreased from 100% to 35.2%. These processes were further validated through experimental methods. During the release process, the trajectory of magnetic particles under the synergistic effect of flow field and magnetic field aligned with expectations. The captured magnetic particles were released from the microchamber within 12 s, achieving a release rate of 100%.
- 13 March 2025
- Published by MDPI AG in Micromachines
- Vol. 16 (3) , 332
Open AccessEfficient Particle Capture and Release Method for DNA Library Preparation on Microfluidics
To address the issues of agglomeration during magnetic particle capture and the incomplete release of these particles during reuse in microfluidic chips for library preparation, a microchamber was utilized to enhance the dispersion area for magnetic particle capture. Additionally, the release of magnetic particles was achieved through the synergistic action of flow field and magnetic field. The simulation results indicated that as the inlet flow velocity varied from 0.02 m/s to 0.16 m/s and the magnet spacing ranged from 1.2 mm to 1.8 mm, the coverage of magnetic particles in the microchamber increased from 17.29% to 63.59%. Meanwhile, the magnetic particle capture rate decreased from 100% to 35.2%. These processes were further validated through experimental methods. During the release process, the trajectory of magnetic particles under the synergistic effect of flow field and magnetic field aligned with expectations. The captured magnetic particles were released from the microchamber within 12 s, achieving a release rate of 100%.
- Open Access
A Rapid Nanofocusing Method for a Deep-Sea Gene Sequencing Microscope Based on Critical Illumination
In the deep-sea environment, the volume available for an in-situ gene sequencer is severely limited. In addition, optical imaging systems are subject to real-time, large-scale defocusing problems caused by ambient temperature fluctuations and vibrational perturbations. To address these challenges, we propose an edge detection algorithm for defocused images based on grayscale gradients and establish a defocus state detection model with nanometer resolution capabilities by relying on the inherent critical illumination light field. The model has been applied to a prototype deep-sea gene sequencing microscope with a 20× objective. It has demonstrated the ability to focus within a dynamic range of ±40 μm with an accuracy of 200 nm by a single iteration within 160 ms. By increasing the number of iterations and exposures, the focusing accuracy can be refined to 78 nm within a dynamic range of ±100 μm within 1.2 s. Notably, unlike conventional photoelectric hill-climbing, this method requires no additional hardware and meets the wide dynamic range, speed, and high-accuracy autofocusing requirements of deep-sea gene sequencing in a compact form factor.
Open AccessA Rapid Nanofocusing Method for a Deep-Sea Gene Sequencing Microscope Based on Critical Illumination
In the deep-sea environment, the volume available for an in-situ gene sequencer is severely limited. In addition, optical imaging systems are subject to real-time, large-scale defocusing problems caused by ambient temperature fluctuations and vibrational perturbations. To address these challenges, we propose an edge detection algorithm for defocused images based on grayscale gradients and establish a defocus state detection model with nanometer resolution capabilities by relying on the inherent critical illumination light field. The model has been applied to a prototype deep-sea gene sequencing microscope with a 20× objective. It has demonstrated the ability to focus within a dynamic range of ±40 μm with an accuracy of 200 nm by a single iteration within 160 ms. By increasing the number of iterations and exposures, the focusing accuracy can be refined to 78 nm within a dynamic range of ±100 μm within 1.2 s. Notably, unlike conventional photoelectric hill-climbing, this method requires no additional hardware and meets the wide dynamic range, speed, and high-accuracy autofocusing requirements of deep-sea gene sequencing in a compact form factor.
- Open Access
- 26 April 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (5) , 565
Low-Temperature and High-Efficiency Solid-Phase Amplification Based on Formamide
The thermal stability of DNA immobilized on a solid surface is one of the factors that affects the efficiency of solid-phase amplification (SP-PCR). Although variable temperature amplification ensures high specificity of the reaction by precisely controlling temperature changes, excessively high temperatures during denaturation can negatively affect DNA stability. Formamide (FA) enables DNA denaturation at lower temperatures, showing potential for SP-PCR. Research on FA’s impacts on DNA microarrays is still limited, necessitating further optimization in exploring the characteristics of FA in SP-PCR according to particular application needs. We immobilized DNA on a chip using a crosslinker and generated DNA microarrays through bridge amplification based on FA denaturation on our automated reaction device. We optimized the denaturation and hybridization parameters of FA, achieving a maximum cluster density of 2.83 × 104 colonies/mm2. Compared to high-temperature denaturation, FA denaturation required a lower template concentration and milder reaction conditions and produced higher cluster density, demonstrating that FA effectively improves hybridization rates on surfaces. Regarding the immobilized DNA stability, the FA group exhibited a 45% loss of DNA, resulting in a 15% higher DNA retention rate compared to the high-temperature group, indicating that FA can better maintain DNA stability. Our study suggests that using FA improves the immobilized DNA stability and amplification efficiency in SP-PCR.
- 26 April 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (5) , 565
Open AccessLow-Temperature and High-Efficiency Solid-Phase Amplification Based on Formamide
The thermal stability of DNA immobilized on a solid surface is one of the factors that affects the efficiency of solid-phase amplification (SP-PCR). Although variable temperature amplification ensures high specificity of the reaction by precisely controlling temperature changes, excessively high temperatures during denaturation can negatively affect DNA stability. Formamide (FA) enables DNA denaturation at lower temperatures, showing potential for SP-PCR. Research on FA’s impacts on DNA microarrays is still limited, necessitating further optimization in exploring the characteristics of FA in SP-PCR according to particular application needs. We immobilized DNA on a chip using a crosslinker and generated DNA microarrays through bridge amplification based on FA denaturation on our automated reaction device. We optimized the denaturation and hybridization parameters of FA, achieving a maximum cluster density of 2.83 × 104 colonies/mm2. Compared to high-temperature denaturation, FA denaturation required a lower template concentration and milder reaction conditions and produced higher cluster density, demonstrating that FA effectively improves hybridization rates on surfaces. Regarding the immobilized DNA stability, the FA group exhibited a 45% loss of DNA, resulting in a 15% higher DNA retention rate compared to the high-temperature group, indicating that FA can better maintain DNA stability. Our study suggests that using FA improves the immobilized DNA stability and amplification efficiency in SP-PCR.
- Open Access
- 31 July 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (8) , 1548
Double-Glued Multi-Focal Bionic Compound Eye Camera
Compound eye cameras are a vital component of bionics. Compound eye lenses are currently used in light field cameras, monitoring imaging, medical endoscopes, and other fields. However, the resolution of the compound eye lens is still low at the moment, which has an impact on the application scene. Photolithography and negative pressure molding were used to create a double-glued multi-focal bionic compound eye camera in this study. The compound eye camera has 83 microlenses, with ommatidium diameters ranging from 400 μm to 660 μm, and a 92.3 degree field-of-view angle. The double-gluing structure significantly improves the optical performance of the compound eye lens, and the spatial resolution of the ommatidium is 57.00 lp mm−1. Additionally, the measurement of speed is investigated. This double-glue compound eye camera has numerous potential applications in the military, machine vision, and other fields.
- 31 July 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (8) , 1548
Open AccessDouble-Glued Multi-Focal Bionic Compound Eye Camera
Compound eye cameras are a vital component of bionics. Compound eye lenses are currently used in light field cameras, monitoring imaging, medical endoscopes, and other fields. However, the resolution of the compound eye lens is still low at the moment, which has an impact on the application scene. Photolithography and negative pressure molding were used to create a double-glued multi-focal bionic compound eye camera in this study. The compound eye camera has 83 microlenses, with ommatidium diameters ranging from 400 μm to 660 μm, and a 92.3 degree field-of-view angle. The double-gluing structure significantly improves the optical performance of the compound eye lens, and the spatial resolution of the ommatidium is 57.00 lp mm−1. Additionally, the measurement of speed is investigated. This double-glue compound eye camera has numerous potential applications in the military, machine vision, and other fields.
- 24 January 2022
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 61 (2) , 022002
Dynamically tunable ultralong photonic nanojets by a curved surface truncated dielectric microcylinder
As for microparticles (microspheres or microcylinders) that form photonic nanojets (PNJs) in the near field, a curved truncated dielectric microcylinder structure (CSTDM) is investigated by the finite element method which can form ultralong PNJs with the longest effective length: 209.49 λ . Changing parameter h of the structure can realize long dynamic range tuning of the effective length of the PNJ. The effective length varies quasi-periodically with h ; the law of the variation of main indicators of the microcylinder is further discussed, such as the effective length, the working distance, peak electric field intensity, and full width at half height.
- 24 January 2022
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 61 (2) , 022002
Dynamically tunable ultralong photonic nanojets by a curved surface truncated dielectric microcylinder
As for microparticles (microspheres or microcylinders) that form photonic nanojets (PNJs) in the near field, a curved truncated dielectric microcylinder structure (CSTDM) is investigated by the finite element method which can form ultralong PNJs with the longest effective length: 209.49 λ . Changing parameter h of the structure can realize long dynamic range tuning of the effective length of the PNJ. The effective length varies quasi-periodically with h ; the law of the variation of main indicators of the microcylinder is further discussed, such as the effective length, the working distance, peak electric field intensity, and full width at half height.