Ruhizan Liza Ahmad Shauri
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ruhizan Liza Ahmad Shauri has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Muhammad Zakwan Abdul Karim
Universiti Teknologi MARA
2 shared publications - Norashikin M. Thamrin
Universiti Teknologi MARA
2 shared publications - Rozita Jailani
Universiti Teknologi MARA
2 shared publications - Amirah Mustapa
Department of Physical Rehabilitation Sciences, Kulliyyah Allied Health Sciences, International Islamic University Malaysia, Pahang, Malaysia
1 shared publication - Haidzir Manaf
Centre for Physiotherapy Studies, Faculty of Health Sciences, Universiti Teknologi MARA, Puncak Alam Campus, Puncak Alam, Selangor, Malaysia
1 shared publication M. A. Rosli
Centre for System Engineering Studies, Faculty of Electrical Engineering, Universiti Teknologi MARA, Shah Alam, Selangor, Malaysia
1 shared publication
Latest Publications
- Open Access
- 1 December 2024
- Published by Institute of Advanced Engineering and Science in International Journal of Advances in Applied Sciences
- Vol. 13 (4) , 787-795
Evaluating telemedicine diabetes mellitus: a mobile health app for type-2 diabetes
Telemedicine diabetes mellitus (Tele-DM) mobile health (mHealth) tool functionality, usefulness, and user feedback were examined in this study. Data from nine distinct users of type-2 diabetes (T2D) patients, healthcare professionals (HCPs), and administrators was analyzed to determine functionality. Data retrieval times increased with database user data amount, according to the study. A 3-month program with five T2D patients reduced weight (0.98 kg) and Hemoglobin A1c (HbA1c) (0.34%). This shows that Tele-DM helps manage diabetes, but more participants are needed to confirm. Nine Tele-DM customers were satisfied with the app's reception, according to 14 online questionnaires. Overall, Tele-DM simplifies diabetic self-management in a novel way. This study shows its potential to transform diabetes management and address major healthcare issues.
- 1 December 2024
- Published by Institute of Advanced Engineering and Science in International Journal of Advances in Applied Sciences
- Vol. 13 (4) , 787-795
Open AccessEvaluating telemedicine diabetes mellitus: a mobile health app for type-2 diabetes
Telemedicine diabetes mellitus (Tele-DM) mobile health (mHealth) tool functionality, usefulness, and user feedback were examined in this study. Data from nine distinct users of type-2 diabetes (T2D) patients, healthcare professionals (HCPs), and administrators was analyzed to determine functionality. Data retrieval times increased with database user data amount, according to the study. A 3-month program with five T2D patients reduced weight (0.98 kg) and Hemoglobin A1c (HbA1c) (0.34%). This shows that Tele-DM helps manage diabetes, but more participants are needed to confirm. Nine Tele-DM customers were satisfied with the app's reception, according to 14 online questionnaires. Overall, Tele-DM simplifies diabetic self-management in a novel way. This study shows its potential to transform diabetes management and address major healthcare issues.
- Open Access
- 1 August 2023
- Published by Institute of Advanced Engineering and Science in Indonesian Journal of Electrical Engineering and Computer Science
- Vol. 31 (2) , 1023-1031
IoT framework of telerehabilitation system with wearable sensors for diabetes mellitus patients
Physical activity is commonly used as a treatment for diabetes patients, although its effectiveness in improving cognitive functions such as learning, thinking, remembering, and decision making is not clear. Regular exercise can gradually improve metabolic abnormalities associated with pre-diabetes and assist patients with type-2 diabetes (T2D) in managing their pharmacological treatment. The usage of mobile health (mHealth) as a tool to help diabetes patients with their diabetes self-management have been demonstrated in previous studies and it can lead to reductions in glycosylated hemoglobin (HbA1c) levels. Heart rate readings during physical activity is beneficial for healthcare professionals (HCP) to ensure appropriate intensity levels for their patients is achieved. Additionally, the list of the tailored physical activities is long, and it is quite challenging for the T2D patients to remember. Therefore, Tele-DM is proposed, consisting of a smartwatch and mobile application that enable remote physiotherapy sessions for T2D patients. The smartwatch transfers the heart rate data to Tele-DM through Google Fit database. The system provides tailored exercise programs to help patients reduce their weight and HbA1c levels. With the ability to facilitate two-way communication between HCP and T2D patients, the Tele-DM system is designed to enable an effective remote rehabilitation process.
- 1 August 2023
- Published by Institute of Advanced Engineering and Science in Indonesian Journal of Electrical Engineering and Computer Science
- Vol. 31 (2) , 1023-1031
Open AccessIoT framework of telerehabilitation system with wearable sensors for diabetes mellitus patients
Physical activity is commonly used as a treatment for diabetes patients, although its effectiveness in improving cognitive functions such as learning, thinking, remembering, and decision making is not clear. Regular exercise can gradually improve metabolic abnormalities associated with pre-diabetes and assist patients with type-2 diabetes (T2D) in managing their pharmacological treatment. The usage of mobile health (mHealth) as a tool to help diabetes patients with their diabetes self-management have been demonstrated in previous studies and it can lead to reductions in glycosylated hemoglobin (HbA1c) levels. Heart rate readings during physical activity is beneficial for healthcare professionals (HCP) to ensure appropriate intensity levels for their patients is achieved. Additionally, the list of the tailored physical activities is long, and it is quite challenging for the T2D patients to remember. Therefore, Tele-DM is proposed, consisting of a smartwatch and mobile application that enable remote physiotherapy sessions for T2D patients. The smartwatch transfers the heart rate data to Tele-DM through Google Fit database. The system provides tailored exercise programs to help patients reduce their weight and HbA1c levels. With the ability to facilitate two-way communication between HCP and T2D patients, the Tele-DM system is designed to enable an effective remote rehabilitation process.
- 1 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 25, 1-6
New Interface using Beaglebone Black for 4-DOF Robot Arm System
This paper describes the application of a microcontroller as the interface device for a four degree of freedom (DOF) robot arm. In the previous development of the robot arm, a microcontroller Arduino Mega 2560 was used as the interface device to run all four joint motors of arm replacing PCI board which could only produce two analogue outputs. However, Arduino Mega 2560 was observed to produce slow computation for real-time application. Thus, the objective of this study is to apply another type of microcontroller that could solve the communication problem between the hardware, the sensors and the host computer. The features of the new microcontroller were investigated in terms of sufficient number of analogue/digital outputs, compatibility of programming software and other technical specifications to fulfill the robot's system requirement. Compared to the previous Arduino controller, the result proved that with the application of Beaglebone Black as the interface device, the closed-loop control of all motor run smoothly with almost four times faster than Arduino Mega 2560 and applicable for multiple analog outputs. Thus, the system interface can be applied to run the combined systems of the robot arm and the hand which requires reliable communication of input/output signals and fast computation time for control in the future.
- 1 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 25, 1-6
New Interface using Beaglebone Black for 4-DOF Robot Arm System
This paper describes the application of a microcontroller as the interface device for a four degree of freedom (DOF) robot arm. In the previous development of the robot arm, a microcontroller Arduino Mega 2560 was used as the interface device to run all four joint motors of arm replacing PCI board which could only produce two analogue outputs. However, Arduino Mega 2560 was observed to produce slow computation for real-time application. Thus, the objective of this study is to apply another type of microcontroller that could solve the communication problem between the hardware, the sensors and the host computer. The features of the new microcontroller were investigated in terms of sufficient number of analogue/digital outputs, compatibility of programming software and other technical specifications to fulfill the robot's system requirement. Compared to the previous Arduino controller, the result proved that with the application of Beaglebone Black as the interface device, the closed-loop control of all motor run smoothly with almost four times faster than Arduino Mega 2560 and applicable for multiple analog outputs. Thus, the system interface can be applied to run the combined systems of the robot arm and the hand which requires reliable communication of input/output signals and fast computation time for control in the future.