Long H. B. Nguyen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Long H. B. Nguyen has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Hai N. Tran
EVtech Co. Ltd, Ba Ria city, Ba Ria - Vung Tau, Vietnam
3 shared publications - Tuyen Dinh Nguyen
Ho Chi Minh City University of Technology (HCMUT), VNU-HCM
3 shared publications - Dong Tran
Department of Power Delivery, Faculty of Electrical and Electroncis Engineering, Ho Chi Minh City University of Technology (HCMUT), VNU-HCM, Ho Chi Minh City, Vietnam
1 shared publication - Minh V. Vo
Xnergy Autonomous Power Technologies, Singapore
1 shared publication - Ravi Nath Tripathi
Next Generation Power Electronics Research Center Kyushu Institute of Technology Fukuoka Japan
1 shared publication Trinh T. K. Nguyen
LITEON Company Pte. Ltd., Lorong Chuan, Singapore
1 shared publication
Latest Publications
- 2 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. PP (4) , 1
A Non-Ecap Wide Range Bidirectional OBC With Multi-function Circuit
The rapid growth of Electric Vehicles (EVs) with larger battery capacities and integrated Vehicle-to-Everything (V2X) applications is accelerating the demand for high-power Bidirectional On-Board Chargers (BOBCs). Conventional BOBC architectures, typically based on Frequency Controlled (FC) CLLLC converters with large Electrolytic Capacitor (E-cap or Ecap), face three critical limitations: 1) low power density and short lifetime of E-cap; 2) complex resonant tank design requiring dual resonant networks for bidirectionality in addition to low inductance ratio for voltage regulation purposes, and 3) high MOSFET turn-off current at the CLLLC stage that elevates switching losses, voltage overshoot, and reliability risks. While active Power Decoupling (PD) concepts have been proposed to mitigate E-cap issues, these solutions often require high capacitance, are only partially utilized in 3-phase mode, and still face reliability challenges in the isolated stage. This paper introduces a novel BOBC architecture featuring a Multi-function Circuit (MC) placed between the AFE and isolated stage. The MC simultaneously performs power decoupling and charging current regulation, enabling the isolated converter to operate purely as a DC transformer (DCX) for galvanic isolation. This MC-DCX approach eliminates bulky E-cap, reduces semiconductor stress, simplifies resonant tank design, improves system reliability, and enhances scalability to both 400V and 800V platforms. A detailed comparison at 22 kW shows lower switching losses, reduced resonant capacitor stress, and improved reliability versus conventional CLLLC designs. The proposed BOBC, integrated with an Auxiliary Power Module (APM) into a compact Integrated Dual Charging Module (IDCM), supports universal grid with 11 kW 1-phase and 22 kW 3-phase charging. Experimental validation confirms the feasibility of the concept. This paper is among the first to provide a systematic comparison of MC-DCX with FC-LLC at the 22 kW level, offering valuable guidance for academic and industrial as BOBCs transition toward higher voltage, higher power, and wider operating ranges.
- 2 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. PP (4) , 1
A Non-Ecap Wide Range Bidirectional OBC With Multi-function Circuit
The rapid growth of Electric Vehicles (EVs) with larger battery capacities and integrated Vehicle-to-Everything (V2X) applications is accelerating the demand for high-power Bidirectional On-Board Chargers (BOBCs). Conventional BOBC architectures, typically based on Frequency Controlled (FC) CLLLC converters with large Electrolytic Capacitor (E-cap or Ecap), face three critical limitations: 1) low power density and short lifetime of E-cap; 2) complex resonant tank design requiring dual resonant networks for bidirectionality in addition to low inductance ratio for voltage regulation purposes, and 3) high MOSFET turn-off current at the CLLLC stage that elevates switching losses, voltage overshoot, and reliability risks. While active Power Decoupling (PD) concepts have been proposed to mitigate E-cap issues, these solutions often require high capacitance, are only partially utilized in 3-phase mode, and still face reliability challenges in the isolated stage. This paper introduces a novel BOBC architecture featuring a Multi-function Circuit (MC) placed between the AFE and isolated stage. The MC simultaneously performs power decoupling and charging current regulation, enabling the isolated converter to operate purely as a DC transformer (DCX) for galvanic isolation. This MC-DCX approach eliminates bulky E-cap, reduces semiconductor stress, simplifies resonant tank design, improves system reliability, and enhances scalability to both 400V and 800V platforms. A detailed comparison at 22 kW shows lower switching losses, reduced resonant capacitor stress, and improved reliability versus conventional CLLLC designs. The proposed BOBC, integrated with an Auxiliary Power Module (APM) into a compact Integrated Dual Charging Module (IDCM), supports universal grid with 11 kW 1-phase and 22 kW 3-phase charging. Experimental validation confirms the feasibility of the concept. This paper is among the first to provide a systematic comparison of MC-DCX with FC-LLC at the 22 kW level, offering valuable guidance for academic and industrial as BOBCs transition toward higher voltage, higher power, and wider operating ranges.
- 26 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 11 (4) , 9306-9318
A Three-Level T-Type LLC Converter With Adaptive Frequency PWM Control for On-Board Charger
The circulating current negatively impacts the performance of LLC converters by increasing losses and current ratings, reducing efficiency, and narrowing the zero-voltage switching (ZVS) range. This article proposes an adaptive frequency pulsewidth modulation control (AFPC) method to enhance the steady-state performance of a three-level T-type LLC (3LTLLC) converter for on-board charger (OBC) applications. The proposed AFPC dynamically adjusts the switching frequency based on real-time battery voltage and charging power data, effectively eliminating circulating current and improving efficiency. Furthermore, this article presents a comprehensive analysis of the current and voltage equations of the resonant tank components, providing estimations of the circulating interval (CI) and voltage gain across typical OBC charging profiles. A transformer design is introduced, optimizing both size and winding structure to achieve the desired leakage inductance while maintaining high efficiency and power density. The effectiveness of the proposed strategy is validated through experimental results from a 3LTLLC resonant converter prototype with a 400-V input and an output range of 220–380 V at a rated power of 7.4 kW. An efficiency improvement of 0.3% is observed during the most common charging intervals between 240 and 340 V.
- 26 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 11 (4) , 9306-9318
A Three-Level T-Type LLC Converter With Adaptive Frequency PWM Control for On-Board Charger
The circulating current negatively impacts the performance of LLC converters by increasing losses and current ratings, reducing efficiency, and narrowing the zero-voltage switching (ZVS) range. This article proposes an adaptive frequency pulsewidth modulation control (AFPC) method to enhance the steady-state performance of a three-level T-type LLC (3LTLLC) converter for on-board charger (OBC) applications. The proposed AFPC dynamically adjusts the switching frequency based on real-time battery voltage and charging power data, effectively eliminating circulating current and improving efficiency. Furthermore, this article presents a comprehensive analysis of the current and voltage equations of the resonant tank components, providing estimations of the circulating interval (CI) and voltage gain across typical OBC charging profiles. A transformer design is introduced, optimizing both size and winding structure to achieve the desired leakage inductance while maintaining high efficiency and power density. The effectiveness of the proposed strategy is validated through experimental results from a 3LTLLC resonant converter prototype with a 400-V input and an output range of 220–380 V at a rated power of 7.4 kW. An efficiency improvement of 0.3% is observed during the most common charging intervals between 240 and 340 V.
- 31 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 10 (2) , 3218-3230
Unbalanced Half-Bridge Split Capacitor Power Decoupling With Multiorder Frequency Control for 800-V On-Board Battery Charger
This paper proposes a new method for the design and control of a Half-bridge Split Capacitor based Power Decoupling (HSC-PD) circuit to eliminate the bulky Electrolytic Capacitors (E-cap) at dc-link, targeting 800V OBC applications with higher reliability and power density. In the proposed method, both capacitance and dc-offset voltage of the decoupling capacitors are designed unbalanced with the bottom capacitor having a dominant effect over the top one, which reduces the decoupling capacitance requirements compared to the previous works. In addition, the effect of lower dc-link capacitance in reducing power rating of the pre-charge resistor, typically used in OBC applications, is presented. This effect, overlooked in previous literature, leads to reducing volume and cost of the OBC. A small signal model of the HSC-PD is introduced, and a modified feedback control strategy is proposed, offering lower memory usage and calculation effort for the DSP microcontroller when compared with conventional Proportional Resonant (PR) controllers. Comparisons of the proposed method with other HSC-PD counterparts as well as with the conventional E-cap method are given. Finally, a 7.4kW prototype of an 820V interleaved totem-pole PFC with HSC-PD is built and tested to verify the superior performance of the proposed method.
- 31 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 10 (2) , 3218-3230
Unbalanced Half-Bridge Split Capacitor Power Decoupling With Multiorder Frequency Control for 800-V On-Board Battery Charger
This paper proposes a new method for the design and control of a Half-bridge Split Capacitor based Power Decoupling (HSC-PD) circuit to eliminate the bulky Electrolytic Capacitors (E-cap) at dc-link, targeting 800V OBC applications with higher reliability and power density. In the proposed method, both capacitance and dc-offset voltage of the decoupling capacitors are designed unbalanced with the bottom capacitor having a dominant effect over the top one, which reduces the decoupling capacitance requirements compared to the previous works. In addition, the effect of lower dc-link capacitance in reducing power rating of the pre-charge resistor, typically used in OBC applications, is presented. This effect, overlooked in previous literature, leads to reducing volume and cost of the OBC. A small signal model of the HSC-PD is introduced, and a modified feedback control strategy is proposed, offering lower memory usage and calculation effort for the DSP microcontroller when compared with conventional Proportional Resonant (PR) controllers. Comparisons of the proposed method with other HSC-PD counterparts as well as with the conventional E-cap method are given. Finally, a 7.4kW prototype of an 820V interleaved totem-pole PFC with HSC-PD is built and tested to verify the superior performance of the proposed method.