Gyung-Su Byun has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Dual-Channel Wearable Ring With MODWT-Based Signal Processing for Non-Invasive Blood Glucose Estimation: A Pilot Study

    by Quoc Cuong Bui, Areum Durey, Juyoung Lee, Gyung-Su Byun

    Diabetes management necessitates regular blood glucose level (BGL) monitoring, but invasive finger-prick glucose monitoring suffer from poor patient compliance due to discomfort, infection risks, and high costs. This study presents a non-invasive BGL monitoring system that utilizes a ring device with maximal overlap discrete wavelet transform (MODWT)-based multiscale signal analysis. The ring device incorporates an anatomically-optimized photoplethysmography (PPG) sensor on finger digit, capturing signals at 850 nm and 523 nm wavelengths. The MODWT framework simultaneously denoises and decomposes PPG signals and their derivatives, including velocity plethysmogram (VPG) and acceleration plethysmography (APG), into multi-frequency scales while maintaining full temporal resolution. High-quality segments are identified through an advanced signal quality index. After data processing, statistical features, including nonlinear measures targeting to glucose-relevant vascular, autonomic, and respiratory mechanisms and complementary linear features, were extracted and optimized through filter-based feature selection. Four machine learning regression models were evaluated using data from 47 participants across three clinical groups (healthy, hypertension, and hypertension with diabetes). Linear support vector regression achieved the superior performance, particularly when using PPG and APG signals with MODWT decomposition, yielding RMSE = 16.023 mg/dL, and 100% accuracy in Clarke plot analysis within Zone A+B under five-fold stratified cross-validation. Fractal dimension features from MODWT-decomposed green channel signals, which characterize the structure of the vasculature, emerges as the most discriminative features for glucose estimation. This integrated approach combining anatomy-based sensor design and physiological-related features from multiscale signal decomposition demonstrates feasibility of a practical approach for wearable and non-invasive glucose monitoring.


  • Open Access

    Automated Internal Defect Identification and Localization Based on a Near-Field SAR Millimeter-Wave Imaging System

    by Quoc Cuong Bui, Weizhi Lin, Qiang Huang, Gyung-Su Byun

    Fast and cost-effective detection of internal defects is essential for structural integrity inspection in various applications such as manufacturing, construction, and aerospace. Current internal non-destructive testing (NDT) methods, such as computed tomography, can be costly, time-consuming, and constrained by object size. The lightweight and affordable millimeter-wave (mmWave) radar has demonstrated the capability of detecting objects beneath surfaces or obstacles through generated near-field synthetic aperture radar (SAR) images. However, its use in precise internal inspection has not been fully explored due to the significant noise in the SAR images and high rate of false identification. To enable accurate and fast inspections using the mmWave radar, this work establishes a robust and automated internal defect detection system. It employs a compact mmWave radar system mounted on a stable rail-based scanning mechanism, generating high-resolution near-field SAR images with an enhanced signal-to-noise ratio through denoising. For fast and accurate detection, an automated defect localization algorithm is developed. The accuracy of detection is ensured by modeling and separating internal defects from disturbances introduced by the scanning mechanism and noise. Experiments were conducted using 3D-printed blocks with synthetic defects to demonstrate the detection capability of the proposed system. Internal defects were accurately detected across variations in shape, material permittivity, depth, and size. The proposed method achieved an average accuracy of 91.7%, outperforming existing methods. The compact design of the radar system enables seamless integration with larger scanning systems, while the automated detection algorithm can be readily implemented as a software module within existing sensing systems. This integration of hardware and software components yields a versatile, low-cost framework for rapid internal health inspection that adapts to various industrial applications and object sizes.


  • Open Access

    A Wireless Data Transfer by Using a Patch Antenna for Biomedical Applications

    by Gyung-Su Byun

    In this paper, a 20 GHz wireless data transfer (WDT) interface for implantable applications is proposed. The proposed WDT utilizes a small-form factor off-chip antenna to transfer data through a human body. By using the implantable antenna, the biomedical WDT system occupies a smaller chip size, which is suitable for future biomedical applications. The proposed WDT system with a small-form factor patch antenna and near-threshold VCO operates at 20 GHz, has a data rate of 1.8 Gb/s and consumes only a low power of 5.4 pJ/b.


  • Open Access

    The Comparison Features of ECG Signal with Different Sampling Frequencies and Filter Methods for Real-Time Measurement

    by Ngoc-Thang Bui, Gyung-Su Byun

    Electrocardiogram (ECG) signals have been used to monitor and diagnose signs of cardiovascular disease and abnormal signals about the human body. ECG signals are typically characterized by the PR, QRS, QT interval, ST-segment, and heart rate (HR) parameters. ECG devices are widely used for many applications, especially for the elderly. However, ECG signals are often affected by noises from the environment. There are mainly two types of noises that affect the ECG signals: low frequencies from muscle activity and 50/60 Hz from the electrical grid. Removing these noises is important for improving the quality of the ECG signal. A clear ECG signal makes it easy to diagnose cardiovascular problems. ECG signals with high sampling frequency are more accurate. However, the noises in the signal will be more obvious and it will be difficult to remove these noises with filters. We analyzed the symmetrical correlation between the sampling frequency of the signal and the parameters of the signal such as signal to noise ratio (SNR) and signal amplitude. This study will compare characterization of ECG signals performed at different sampling frequencies before and after applying infinite impulse response (IIR) and symmetric finite impulse response (FIR) filters. Therefore, it is critical that the sampling frequency is consistent at the same frequency of the ECG signal for accurate diagnosis. Furthermore, the approach can be also important for the device to help reduce the device’s computing power and hardware resources. Our results were tested with the MIT/ BIH database at 360 Hz sampling frequency with 11-bit resolution. We also experimented with the device operating in real-time with a sampling frequency from 100 Hz to 2133 Hz and a 24-bit resolution. The test results show the advantages of the symmetric FIR filter over IIR when applied to the filtering of ECG signals. The study’s conclusions can be applied to real-world devices to improve the quality of ECG signals.


  • A 3-D Reconfigurable Memory I/O Interface Using a Quad-Band Interconnect

    by Xiaoyan Wang, Gyung-Su Byun

    This article presents a 3-D reconfigurable memory I/O transceiver using a quad-band interconnect (QBI). The 3-D QBI provides I/O data reconfigurability, decreases latency, and reduces pin count for future compact mobile memory interfaces. The 3-D integrated circuit (3-D IC) technique is utilized to reduce signal latency and improve signal integrity. A novel quad-band transformer is proposed to achieve reconfigurable four-band data communication and reduce the I/O pin count by four times. A two-tier QBI die-stack is implemented to verify the QBI design. Face-to-face configuration with $\mu $ bump interconnects is used to save cost. The QBI chips are designed and fabricated in a 180-nm CMOS process. The chip areas of the top and bottom dies are 1.77 and 1.4 mm 2 , respectively. The measured data rates, with bit error rate (BER) $< 10^{-15}$ , are up to 2 Gb/s in the baseband (BB) and 2.3, 2.5, and 3 Gb/s in RF-bands. The QBI energy efficiencies, with a 1.8-V supply voltage, are 5.9 pJ/b in the BB and 6.2, 7.4, and 8 pJ/b in the RF-bands.


  • Open Access

    A Sub-THz Wireless Power Transfer for Non-Contact Wafer-Level Testing

    by Hanh Dang-Ba, Gyung-Su Byun

    In this paper, a sub-THz wireless power transfer (WPT) interface for non-contact wafer-level testing is proposed. The on-chip sub-THz couplers, which have been designed and analyzed with 3-D EM simulations, could be integrated into the WPT to transfer power through an air media. By using the sub-THz coils, the WPT occupies an extremely small chip size, which is suitable for future wafer-testing applications. In the best power transfer efficiency (PTE) condition of the WPT, the maximum power delivery is limited to 2.5 mW per channel. However, multi-channel sub-THz WPT could be a good solution to provide enough power for testing purposes while remaining high PTE. Simulated on a standard 28-nm CMOS technology, the proposed eight-channel WPT could provide 20 mW power with the PTE of 16%. The layouts of the eight-channel WPT transmitter and receiver occupy only 0.12 mm2, 0.098 mm2, respectively.


  • Three-Dimensional Pipeline ADC Utilizing TSV/ Design Optimization and Memristor Ratioed Logic

    by Nahid Mirzaie, Ahmed Alzahmi, Hossein Shamsi, Gyung-Su Byun

    High-performance, low-power-consumption, and high-accuracy analog-to-digital converters (ADCs) with a compact area are necessary for a wide range of current applications. This paper presents a pipeline ADC architecture with a novel 3-D clock distribution network utilizing through-silicon via-induced benefits. It also implements memristor ratioed logic as the basic elements of digital error correction subblock to further decrease the area, delay, and power consumption. In addition, an optimization technique using computational intelligence is applied to maximize the overall system performance. The proposed 3-D pipeline ADC is designed in a 65-nm CMOS technology and shows significant improvement regarding dynamic performance, energy efficiency, area, and clock accuracy compared with that of conventional 2-D ADC designs.


  • Open Access

    High‐speed mobile memory I/O interface using multi‐modulation signalling

    by Y. Yu, G.‐S. Byun

    The proposed multi‐band multi‐modulation I/O (MMI) for mobile memory interface consists of two RF‐band and 4‐PAM (pulse‐amplitude modulation) transceivers for simultaneous bidirectional read/write operations on a shared single‐ended 5 cm off‐chip transmission line. A novel band‐selective transformer is introduced to combine and split two amplitude shift keying modulated RF‐bands with a 4‐PAM baseband for transmitting and receiving multiple data concurrently. The MMI interface consumes 2.8 pJ/b from a 1.2 V supply voltage. Testing results show that the MMI interface achieves an overall data rate of 14 Gb/s/pin. It is implemented in a 65 nm CMOS process with chip area of 0.25 mm 2 .

  • Open Access

    An Optimal Design Methodology for Yield-Improved and Low-Power Pipelined ADC

    by Nahid Mirzaie, Gyung-Su Byun

    An energy-efficient, high-performance, and yield-improved analog to digital converter (ADC) design using a multi-objective evolutionary algorithm is demonstrated. The proposed ADC design algorithm incorporates several techniques to enable simultaneous improvement of yield and performance. With the same accuracy, the proposed approach can achieve a significant reduction of computational burden compared with the modified Monte-Carlo (MC)-based yield improvement methods integrating Latin-hypercube sampling (LHS) or trimmed-sample MC. A prototype chip based on the proposed design is fabricated in a 0.13lm CMOS process at 150 MS/s. The results show the ADC achieves an SFDR of 65.48 dB and SNDR of 58.15 dB while dissipating 12 mW from a 1 V power supply. The results also yield a figure of merit (FoM) of 121 fJ/conversion step.