Haiyu Huang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Haiyu Huang has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
Deji Akinwande
Department of Electrical and Computer Engineering, University of Texas at Austin, Austin, TX 78712, USA
4 shared publicationsPai-Yen Chen
Department of Electrical and Computer Engineering
3 shared publications- Mark Ming-Cheng Cheng
Department of Electrical and Computer Engineering, The University of Alabama, Tuscaloosa, AL 35487, USA
2 shared publications - Pai-Yen Chen
Department of Electrical and Computer Engineering, University of Illinois Chicago, Chicago, IL 60607, USA
2 shared publications Ye Hu
Houston Methodist Hospital Research Institute, Houston, TX 77030, USA
2 shared publicationsYong Ren
Department of Electronic Engineering
2 shared publications
Latest Publications
- Open Access
- 9 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 68 (11) , 4846-4854
Compact, Flexible Harmonic Transponder Sensor With Multiplexed Sensing Capabilities for Rapid, Contactless Microfluidic Diagnosis
In this article, we design and experimentally demonstrate a flexible, low-profile harmonic transponder sensor, capable of performing multiplexed fluidic sensing. The harmonic transponder comprises multiple reconfigurable electrically small antennas (ESAs) integrated with microfluidic channels for receiving radio frequency (RF) signals at the fundamental frequencies (f₀), as well as a broadband microstrip monopole for retransmitting the second-harmonic signal (2 f₀) to a sniffer. Such a frequency orthogonality can help suppressing possible echoes, clutters, and crosstalks in the rich-scattering environment. We show that injection of different liquid samples into a microfluidic channel, which tunes the operating frequency of an ESA, can be precisely recognized by analyzing the shift of peak second-harmonic received signal strength indicator (RSSI) in the frequency-hopping spread spectrum (FHSS). We also demonstrate the possibility of performing rapid and multiplexed noncontact detection with the proposed harmonic transponder sensor. We envision that this battery-free and lightweight multiplexing wireless sensor may benefit various Internet-of-Things (IoTs) and healthcare applications, such as rapid contactless point-of-care (POC) and drive-through tests.
- 9 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 68 (11) , 4846-4854
Open AccessCompact, Flexible Harmonic Transponder Sensor With Multiplexed Sensing Capabilities for Rapid, Contactless Microfluidic Diagnosis
In this article, we design and experimentally demonstrate a flexible, low-profile harmonic transponder sensor, capable of performing multiplexed fluidic sensing. The harmonic transponder comprises multiple reconfigurable electrically small antennas (ESAs) integrated with microfluidic channels for receiving radio frequency (RF) signals at the fundamental frequencies (f₀), as well as a broadband microstrip monopole for retransmitting the second-harmonic signal (2 f₀) to a sniffer. Such a frequency orthogonality can help suppressing possible echoes, clutters, and crosstalks in the rich-scattering environment. We show that injection of different liquid samples into a microfluidic channel, which tunes the operating frequency of an ESA, can be precisely recognized by analyzing the shift of peak second-harmonic received signal strength indicator (RSSI) in the frequency-hopping spread spectrum (FHSS). We also demonstrate the possibility of performing rapid and multiplexed noncontact detection with the proposed harmonic transponder sensor. We envision that this battery-free and lightweight multiplexing wireless sensor may benefit various Internet-of-Things (IoTs) and healthcare applications, such as rapid contactless point-of-care (POC) and drive-through tests.
- Open Access
- 1 January 2018
- Published by Wiley in Wireless Communications and Mobile Computing
- Vol. 2018 (1)
Advanced Wireless Communications and Mobile Computing Technologies for the Internet of Things
- 1 January 2018
- Published by Wiley in Wireless Communications and Mobile Computing
- Vol. 2018 (1)
Open AccessAdvanced Wireless Communications and Mobile Computing Technologies for the Internet of Things
- Open Access
- 9 May 2016
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 2 (1) , 16018
Chemical-sensitive graphene modulator with a memory effect for internet-of-things applications
Modern internet of things (IoTs) and ubiquitous sensor networks could potentially take advantage of chemically sensitive nanomaterials and nanostructures. However, their heterogeneous integration with other electronic modules on a networked sensor node, such as silicon-based modulators and memories, is inherently challenging because of compatibility and integration issues. Here we report a novel paradigm for sensing modulators: a graphene field-effect transistor device that directly modulates a radio frequency (RF) electrical carrier signal when exposed to chemical agents, with a memory effect in its electrochemical history. We demonstrated the concept and implementation of this graphene-based sensing modulator through a frequency-modulation (FM) experiment conducted in a modulation cycle consisting of alternating phases of air exposure and ethanol or water treatment. In addition, we observed an analog memory effect in terms of the charge neutrality point of the graphene, Vcnp, which strongly influences the FM results, and developed a calibration method using electrochemical gate-voltage pulse sequences. This graphene-based multifunctional device shows great potential for use in a simple, low-cost, and ultracompact nanomaterial-based nodal architecture to enable continuous, real-time event-based monitoring in pervasive healthcare IoTs, ubiquitous security systems, and other chemical/molecular/gas monitoring applications.
- 9 May 2016
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 2 (1) , 16018
Open AccessChemical-sensitive graphene modulator with a memory effect for internet-of-things applications
Modern internet of things (IoTs) and ubiquitous sensor networks could potentially take advantage of chemically sensitive nanomaterials and nanostructures. However, their heterogeneous integration with other electronic modules on a networked sensor node, such as silicon-based modulators and memories, is inherently challenging because of compatibility and integration issues. Here we report a novel paradigm for sensing modulators: a graphene field-effect transistor device that directly modulates a radio frequency (RF) electrical carrier signal when exposed to chemical agents, with a memory effect in its electrochemical history. We demonstrated the concept and implementation of this graphene-based sensing modulator through a frequency-modulation (FM) experiment conducted in a modulation cycle consisting of alternating phases of air exposure and ethanol or water treatment. In addition, we observed an analog memory effect in terms of the charge neutrality point of the graphene, Vcnp, which strongly influences the FM results, and developed a calibration method using electrochemical gate-voltage pulse sequences. This graphene-based multifunctional device shows great potential for use in a simple, low-cost, and ultracompact nanomaterial-based nodal architecture to enable continuous, real-time event-based monitoring in pervasive healthcare IoTs, ubiquitous security systems, and other chemical/molecular/gas monitoring applications.
- Open Access
- 6 January 2016
- Published by Springer Nature in Scientific Reports
- Vol. 6 (1) , 18795
A zero power harmonic transponder sensor for ubiquitous wireless μL liquid-volume monitoring
Autonomous liquid-volume monitoring is crucial in ubiquitous healthcare. However, conventional approach is based on either human visual observation or expensive detectors, which are costly for future pervasive monitoring. Here we introduce a novel approach based on passive harmonic transponder antenna sensor and frequency hopping spread spectrum (FHSS) pattern analysis, to provide a very low cost wireless μL-resolution liquid-volume monitoring without battery or digital circuits. In our conceptual demonstration, the harmonic transponder comprises of a passive nonlinear frequency multiplier connected to a metamaterial-inspired 3-D antenna designed to be highly sensitive to the liquid-volume within a confined region. The transponder first receives some FHSS signal from an interrogator, then converts such signal to its harmonic band and re-radiates through the antenna sensor. The harmonic signal is picked up by a sniffer receiver and decoded through pattern analysis of the high dimensional FHSS signal strength data. A robust, zero power, absolute accuracy wireless liquid-volume monitoring is realized in the presence of strong direct coupling, background scatters, distance variance as well as near-field human-body interference. The concepts of passive harmonic transponder sensor, metamaterial-inspired antenna sensor and FHSS pattern analysis based sensor decoding may help establishing cost-effective, energy-efficient and intelligent wireless pervasive healthcare monitoring platforms.
- 6 January 2016
- Published by Springer Nature in Scientific Reports
- Vol. 6 (1) , 18795
Open AccessA zero power harmonic transponder sensor for ubiquitous wireless μL liquid-volume monitoring
Autonomous liquid-volume monitoring is crucial in ubiquitous healthcare. However, conventional approach is based on either human visual observation or expensive detectors, which are costly for future pervasive monitoring. Here we introduce a novel approach based on passive harmonic transponder antenna sensor and frequency hopping spread spectrum (FHSS) pattern analysis, to provide a very low cost wireless μL-resolution liquid-volume monitoring without battery or digital circuits. In our conceptual demonstration, the harmonic transponder comprises of a passive nonlinear frequency multiplier connected to a metamaterial-inspired 3-D antenna designed to be highly sensitive to the liquid-volume within a confined region. The transponder first receives some FHSS signal from an interrogator, then converts such signal to its harmonic band and re-radiates through the antenna sensor. The harmonic signal is picked up by a sniffer receiver and decoded through pattern analysis of the high dimensional FHSS signal strength data. A robust, zero power, absolute accuracy wireless liquid-volume monitoring is realized in the presence of strong direct coupling, background scatters, distance variance as well as near-field human-body interference. The concepts of passive harmonic transponder sensor, metamaterial-inspired antenna sensor and FHSS pattern analysis based sensor decoding may help establishing cost-effective, energy-efficient and intelligent wireless pervasive healthcare monitoring platforms.
- Open Access
- 19 March 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Translational Engineering in Health and Medicine
- Vol. 2, 1-8
RFID Tag Helix Antenna Sensors for Wireless Drug Dosage Monitoring
Miniaturized helix antennas are integrated with drug reservoirs to function as RFID wireless tag sensors for real-time drug dosage monitoring. The general design procedure of this type of biomedical antenna sensors is proposed based on electromagnetic theory and finite element simulation. A cost effective fabrication process is utilized to encapsulate the antenna sensor within a biocompatible package layer using PDMS material, and at the same time form a drug storage or drug delivery unit inside the sensor. The in vitro experiment on two prototypes of antenna sensor-drug reservoir assembly have shown the ability to monitor the drug dosage by tracking antenna resonant frequency shift from 2.4-2.5-GHz ISM band with realized sensitivity of 1.27 μ l/MHz for transdermal drug delivery monitoring and 2.76- μ l/MHz sensitivity for implanted drug delivery monitoring.
- 19 March 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Translational Engineering in Health and Medicine
- Vol. 2, 1-8
Open AccessRFID Tag Helix Antenna Sensors for Wireless Drug Dosage Monitoring
Miniaturized helix antennas are integrated with drug reservoirs to function as RFID wireless tag sensors for real-time drug dosage monitoring. The general design procedure of this type of biomedical antenna sensors is proposed based on electromagnetic theory and finite element simulation. A cost effective fabrication process is utilized to encapsulate the antenna sensor within a biocompatible package layer using PDMS material, and at the same time form a drug storage or drug delivery unit inside the sensor. The in vitro experiment on two prototypes of antenna sensor-drug reservoir assembly have shown the ability to monitor the drug dosage by tracking antenna resonant frequency shift from 2.4-2.5-GHz ISM band with realized sensitivity of 1.27 μ l/MHz for transdermal drug delivery monitoring and 2.76- μ l/MHz sensitivity for implanted drug delivery monitoring.
- 27 September 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nanotechnology
- Vol. 11 (6) , 1201-1211
Distributed Amplifiers Based on Spindt-Type Field-Emission Nanotriodes
In this paper, we discuss and analyze the design of a high-frequency, broadband distributed amplifier (DA) based on a 2-D array of field-emission nanotriodes (FENT) consisting of self-aligned gate around a nanomaterial field emitter. We propose here a physics-based device model to characterize dc properties of individual FENTs and a transmission-line circuit for evaluating and optimizing relevant ac properties, including power gain and impedance matching. Our discussion starts from the FENT array's dc characteristics and covers its radio frequency and microwave properties, considering effects of array density, geometry, FENT dimensions, and nanoemitter work function, in order to maximize power gain and bandwidth for high-frequency applications (30-100 GHz). Finally, we consider the practical design of a transmitter front end for wireless systems, combining the FENT-array DA with a tapered open-ended waveguide antenna, significantly improving matching and power radiation efficiency. Our results are of interest for imaging, sensing, satellite communications, defense, and security at 94 GHz.
- 27 September 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nanotechnology
- Vol. 11 (6) , 1201-1211
Distributed Amplifiers Based on Spindt-Type Field-Emission Nanotriodes
In this paper, we discuss and analyze the design of a high-frequency, broadband distributed amplifier (DA) based on a 2-D array of field-emission nanotriodes (FENT) consisting of self-aligned gate around a nanomaterial field emitter. We propose here a physics-based device model to characterize dc properties of individual FENTs and a transmission-line circuit for evaluating and optimizing relevant ac properties, including power gain and impedance matching. Our discussion starts from the FENT array's dc characteristics and covers its radio frequency and microwave properties, considering effects of array density, geometry, FENT dimensions, and nanoemitter work function, in order to maximize power gain and bandwidth for high-frequency applications (30-100 GHz). Finally, we consider the practical design of a transmitter front end for wireless systems, combining the FENT-array DA with a tapered open-ended waveguide antenna, significantly improving matching and power radiation efficiency. Our results are of interest for imaging, sensing, satellite communications, defense, and security at 94 GHz.