Chengyang Huang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Chengyang Huang has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Francesco Lanza di Scalea
Jacobs School of Engineering, University of California San Diego, La Jolla, USA
6 shared publications Francesco Lanza di Scalea
Experimental Mechanics & NDE Laboratory, Department of Structural Engineering, University of California San Diego, La Jolla, CA 92093 USA
5 shared publicationsAli Zare Hosseinzadeh
3 shared publications- Ali Zare Hosseinzadeh
Department of Structural Engineering, Experimental Mechanics, NDE and SHM Laboratory, University of California San Diego, La Jolla, CA, USA
2 shared publications - Saeed Khaleghi
Department of Structural Engineering University of California San Diego La Jolla CA 92093 USA
2 shared publications Bradley Yuhasz
1 shared publication
Latest Publications
- Open Access
- 1 June 2026
- Published by Elsevier in Composites Part B: Engineering
- Vol. 324
Nondestructive identification of cure state in composites using noncontact ultrasonic guided wave testing
- 1 June 2026
- Published by Elsevier in Composites Part B: Engineering
- Vol. 324
Open AccessNondestructive identification of cure state in composites using noncontact ultrasonic guided wave testing
- Open Access
- 16 February 2026
- Published by Elsevier in SSRN Electronic Journal
Nondestructive identification of cure state in composites using noncontact ultrasonic guided wave testing
This paper presents a nondestructive, noncontact monitoring system for estimating the degree of cure in thermosetting composites. The Green’s function of the composite laminate is extracted through ultrasonic guided wave excitation using a pulsed laser, followed by deconvolution of signals received by a pair of ultrasonic transducers (dual-output scheme). The monitoring hardware is completely noncontact and allows ultrasonic measurements to be completed within sub-millisecond acquisition windows, with potential use for real-time control during advanced manufacturing processes. A segmental-averaged Normalized Cross Power Spectrum (NCPS) operation is utilized as a robust method to recover both phase and magnitude of the Green’s function while suppressing incoherent noise at the receivers. The viscoelastic constants of the carbon fiber reinforced polymer composite are then identified by an inverse algorithm that uses Semi-Analytical Finite Element (SAFE) as the forward model and Simulated Annealing (SA) as the optimization tool. The viscoelastic constants obtained from the wave inversion are favorably compared to independent measurements from Dynamic Mechanical Analysis (DMA) and Differential Scanning Calorimetry (DSC) tests. Validation on unidirectional laminates fabricated at three different cure states demonstrates that the matrix-dominated viscoelastic constants—particularly the transverse normal and transverse shear components—exhibit strong sensitivity to the level of cure. These results show promise for a potential future use of this technique for real-time, noncontact, physics-informed cure state monitoring for in-process control and post-cure quality control, potentially reducing variability, cycle time, and scrap.
- 16 February 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessNondestructive identification of cure state in composites using noncontact ultrasonic guided wave testing
This paper presents a nondestructive, noncontact monitoring system for estimating the degree of cure in thermosetting composites. The Green’s function of the composite laminate is extracted through ultrasonic guided wave excitation using a pulsed laser, followed by deconvolution of signals received by a pair of ultrasonic transducers (dual-output scheme). The monitoring hardware is completely noncontact and allows ultrasonic measurements to be completed within sub-millisecond acquisition windows, with potential use for real-time control during advanced manufacturing processes. A segmental-averaged Normalized Cross Power Spectrum (NCPS) operation is utilized as a robust method to recover both phase and magnitude of the Green’s function while suppressing incoherent noise at the receivers. The viscoelastic constants of the carbon fiber reinforced polymer composite are then identified by an inverse algorithm that uses Semi-Analytical Finite Element (SAFE) as the forward model and Simulated Annealing (SA) as the optimization tool. The viscoelastic constants obtained from the wave inversion are favorably compared to independent measurements from Dynamic Mechanical Analysis (DMA) and Differential Scanning Calorimetry (DSC) tests. Validation on unidirectional laminates fabricated at three different cure states demonstrates that the matrix-dominated viscoelastic constants—particularly the transverse normal and transverse shear components—exhibit strong sensitivity to the level of cure. These results show promise for a potential future use of this technique for real-time, noncontact, physics-informed cure state monitoring for in-process control and post-cure quality control, potentially reducing variability, cycle time, and scrap.
- 13 February 2026
- Published by Springer Nature
- p. 137-147
Damage Imaging in Stiffened Composite Panels by Ultrasonic Sparse Array Matched Field Processing
- 13 February 2026
- Published by Springer Nature
- p. 137-147
Damage Imaging in Stiffened Composite Panels by Ultrasonic Sparse Array Matched Field Processing
- 13 February 2026
- Published by Springer Nature
- p. 109-117
Nondestructive Ultrasonic Testing of Aerospace Composite Parts via Efficient Inversion of Elastic Constants
- 13 February 2026
- Published by Springer Nature
- p. 109-117
Nondestructive Ultrasonic Testing of Aerospace Composite Parts via Efficient Inversion of Elastic Constants
- Open Access
- 8 February 2026
- Published by Elsevier in Ultrasonics
- Vol. 163, 107992
A physics-informed eigenfilter for artifact removal in ultrasonic scanning videos for structural inspection
- 8 February 2026
- Published by Elsevier in Ultrasonics
- Vol. 163, 107992
Open AccessA physics-informed eigenfilter for artifact removal in ultrasonic scanning videos for structural inspection
- 9 May 2024
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12951, 63-354
Improvements on focused tactile feedback using time reversal mirror
This paper discusses two improvements to localized tactile feedback on a transparent surface using Time Reversal Mirror (TRM) of ultrasonic guided waves. A mock-up device comprising a glass plate of 150 × 200 × 1 mm3 with a 12-element sparse piezoelectric actuator array bonded at the boundary of the plate is constructed together with driving electronics. The transfer function from each actuator to an arbitrary focus point is first recorded using a laser doppler vibrometer. The re-emission waveforms are then generated by convolving the time-reversed transfer function with a target signal to control the shape of the vibration at the focus point. The re-emitted waveforms are compressed to binary signals to improve the peak displacement of the focused wave field. The mock-up device obtains a peak amplitude of 19 μm on the plate with a peak-to-peak driving voltage of 150 V. Two improvements to the tactile feedback using ultrasonic TRM are described. First, the undesired conversion of ultrasonic vibration to audible spectra resulting from the coupling of the fingertip and the plate surface is investigated. The authors show that despite the inevitable frequency shift, the tone of the audible leakage can be controlled by the repetition period of the TRM. Second, the tactile feeling of a single-point focus of ultrasonic guided wave is acute and hard to detect due to its small resolution cell compared to the size of a fingertip. The authors propose a dual-point focus scheme, the distance of which is less than that of two-points discrimination, to enlarge the perceivable region without changing the spectra of the re-emission signals.
- 9 May 2024
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12951, 63-354
Improvements on focused tactile feedback using time reversal mirror
This paper discusses two improvements to localized tactile feedback on a transparent surface using Time Reversal Mirror (TRM) of ultrasonic guided waves. A mock-up device comprising a glass plate of 150 × 200 × 1 mm3 with a 12-element sparse piezoelectric actuator array bonded at the boundary of the plate is constructed together with driving electronics. The transfer function from each actuator to an arbitrary focus point is first recorded using a laser doppler vibrometer. The re-emission waveforms are then generated by convolving the time-reversed transfer function with a target signal to control the shape of the vibration at the focus point. The re-emitted waveforms are compressed to binary signals to improve the peak displacement of the focused wave field. The mock-up device obtains a peak amplitude of 19 μm on the plate with a peak-to-peak driving voltage of 150 V. Two improvements to the tactile feedback using ultrasonic TRM are described. First, the undesired conversion of ultrasonic vibration to audible spectra resulting from the coupling of the fingertip and the plate surface is investigated. The authors show that despite the inevitable frequency shift, the tone of the audible leakage can be controlled by the repetition period of the TRM. Second, the tactile feeling of a single-point focus of ultrasonic guided wave is acute and hard to detect due to its small resolution cell compared to the size of a fingertip. The authors propose a dual-point focus scheme, the distance of which is less than that of two-points discrimination, to enlarge the perceivable region without changing the spectra of the re-emission signals.
- 9 May 2024
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12951, 32-168
Passive ultrasonic sensing for NDT and SHM
This keynote presentation will cover passive methods for ultrasonic NDT and SHM. These methods apply to cases where the test structure is subjected to uncontrolled excitations (such as from ambient loads) or to a limited number of controlled excitations. In these cases, proper analysis of the reception signals can reveal surprisingly accurate information from array analysis, such as imaging of internal defects. The effort here is to obtain as much information as possible from the receiver signals while exploiting at a minimum the excitation signals in the beamforming process. Examples will be shown for NDT imaging of holes in an aluminum block via plane-wave beamforming and SHM of a composite wind turbine blade via Matched-Field Processing imaging.
- 9 May 2024
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12951, 32-168
Passive ultrasonic sensing for NDT and SHM
This keynote presentation will cover passive methods for ultrasonic NDT and SHM. These methods apply to cases where the test structure is subjected to uncontrolled excitations (such as from ambient loads) or to a limited number of controlled excitations. In these cases, proper analysis of the reception signals can reveal surprisingly accurate information from array analysis, such as imaging of internal defects. The effort here is to obtain as much information as possible from the receiver signals while exploiting at a minimum the excitation signals in the beamforming process. Examples will be shown for NDT imaging of holes in an aluminum block via plane-wave beamforming and SHM of a composite wind turbine blade via Matched-Field Processing imaging.
- 9 May 2024
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12951, 61-338
Passive ultrasonic beamforming for fast and efficient imaging
This work explores the opportunity for utilizing ultrasonic arrays in a passive manner to increase imaging speed and accuracy, compared to conventional ultrasonic beamforming approaches. While conventional beamforming requires the use of many transmitters as well as receivers, the possibility exists to minimize the number of transmitters and exploit the normalized cross-power spectrum operator to extract "virtual" Impulse Response Functions between pairs of (only) receivers. In principle, this possibility would allow, for example, the use of a single transmitter element and processing the remaining elements as receivers (passively) to obtain similar image quality as using each element as both transmitter and receiver (as done, for example, in a Full Matrix Capture mode). By minimizing the number of transmitters, it would be possible to significantly increase imaging speed (ultrafast imaging) and simplify multiplexer hardware (few high-voltage output channels). The normalized cross-power spectrum could eliminate the distortion in the phase of the Impulse Response Functions which is commonly seen in active transmission modalities. These exciting possibilities are explored in the case of imaging defects in structural components.
- 9 May 2024
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12951, 61-338
Passive ultrasonic beamforming for fast and efficient imaging
This work explores the opportunity for utilizing ultrasonic arrays in a passive manner to increase imaging speed and accuracy, compared to conventional ultrasonic beamforming approaches. While conventional beamforming requires the use of many transmitters as well as receivers, the possibility exists to minimize the number of transmitters and exploit the normalized cross-power spectrum operator to extract "virtual" Impulse Response Functions between pairs of (only) receivers. In principle, this possibility would allow, for example, the use of a single transmitter element and processing the remaining elements as receivers (passively) to obtain similar image quality as using each element as both transmitter and receiver (as done, for example, in a Full Matrix Capture mode). By minimizing the number of transmitters, it would be possible to significantly increase imaging speed (ultrafast imaging) and simplify multiplexer hardware (few high-voltage output channels). The normalized cross-power spectrum could eliminate the distortion in the phase of the Impulse Response Functions which is commonly seen in active transmission modalities. These exciting possibilities are explored in the case of imaging defects in structural components.
- 26 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 71 (5) , 518-535
Ultrasparse Ultrasonic Synthetic Aperture Focus Imaging by Passive Sensing
Ultrasonic Synthetic Aperture Focus Techniques (SAFTs) using less than the total number of available array elements to transmit (“sparse” transmissions) have been recently used in both medical imaging and industrial NDT imaging to increase test speed and simplify multiplexer hardware. The challenge of sparse arrays is to obtain a reasonable image quality given the reduced transmitter-receiver combinations available to the beamforming process. This paper proposes a “ultrasparse” SAFT method that employs a minimum number of transmitter elements (from one to four elements only) to obtain an entire Full-Matrix Capture (FMC) set of waveforms. Specifically, a “virtual” FMC is obtained from normalized cross-power spectra between each array element pair in an implementation of “passive” ultrasonic sensing. In order to maintain high image quality without sacrificing imaging speed (e.g. applying a minimal initial time delay and keeping a short time recording window), several key steps have to be taken in this “passive” imaging mode, specifically (a) the use of carefully-designed segment-averaged normalized cross-power spectrum for robust passive reconstruction of the ultrasonic Impulse Response Function ( IRF ) between two receivers, (b) the use of both the causal and acausal portions of the passively-reconstructed IRF s, and (c) the compounding of multiple wave modes in the beamforming process. These steps also ensure the elimination of the near-field blind zone hence potentially enabling near-field imaging. The paper first reviews the theory of passive IRF reconstruction between two receivers, comparing time-averaged cross-correlation vs. segment-averaged normalized cross-power spectrum, and then demonstrates the application to ultrasparse SAFT FMC imaging of drilled holes in an aluminum block using a linear transducer array where only one to four elements are used in transmission.
- 26 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 71 (5) , 518-535
Ultrasparse Ultrasonic Synthetic Aperture Focus Imaging by Passive Sensing
Ultrasonic Synthetic Aperture Focus Techniques (SAFTs) using less than the total number of available array elements to transmit (“sparse” transmissions) have been recently used in both medical imaging and industrial NDT imaging to increase test speed and simplify multiplexer hardware. The challenge of sparse arrays is to obtain a reasonable image quality given the reduced transmitter-receiver combinations available to the beamforming process. This paper proposes a “ultrasparse” SAFT method that employs a minimum number of transmitter elements (from one to four elements only) to obtain an entire Full-Matrix Capture (FMC) set of waveforms. Specifically, a “virtual” FMC is obtained from normalized cross-power spectra between each array element pair in an implementation of “passive” ultrasonic sensing. In order to maintain high image quality without sacrificing imaging speed (e.g. applying a minimal initial time delay and keeping a short time recording window), several key steps have to be taken in this “passive” imaging mode, specifically (a) the use of carefully-designed segment-averaged normalized cross-power spectrum for robust passive reconstruction of the ultrasonic Impulse Response Function ( IRF ) between two receivers, (b) the use of both the causal and acausal portions of the passively-reconstructed IRF s, and (c) the compounding of multiple wave modes in the beamforming process. These steps also ensure the elimination of the near-field blind zone hence potentially enabling near-field imaging. The paper first reviews the theory of passive IRF reconstruction between two receivers, comparing time-averaged cross-correlation vs. segment-averaged normalized cross-power spectrum, and then demonstrates the application to ultrasparse SAFT FMC imaging of drilled holes in an aluminum block using a linear transducer array where only one to four elements are used in transmission.