Lijie Yue
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Lijie Yue has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Kun Xie
College of Material Science and Engineering, Shandong University of Science and Technology, Qingdao 266590, People's Republic of China
2 shared publications- Feng Wang
State Key Laboratory of Chemical Resource Engineering Beijing Key Laboratory of Electrochemical Process and Technology for Materials Beijing University of Chemical Technology Beijing People's Republic of China
1 shared publication Minghui Yang
College of Material Science and Engineering, Shandong University of Science and Technology, Qingdao 266590, People's Republic of China
1 shared publicationOuyang Weizhen
The School of Materials Science and Engineering, Beijing University of Chemical Technology, Beijing, People's Republic of China, and The State Key Laboratory for Metallic Corrosion and Protection
1 shared publicationShuxin Zhang
College of Material Science and Engineering, Shandong University of Science and Technology, Qingdao 266590, People's Republic of China
1 shared publicationXu Chunchun
The School of Materials Science and Engineering, Beijing University of Chemical Technology, Beijing, People's Republic of China, and The State Key Laboratory for Metallic Corrosion and Protection
1 shared publication
Latest Publications
- Open Access
- 1 March 2020
- Published by IOP Publishing in Materials Research Express
- Vol. 7 (3) , 036517
Study on corrosion behavior of TWIP steel and properties of surface electroless Ni-P coatings
In this study, the corrosion behavior and corrosion resistance of TWIP (Twinning Induced Plasticity) steels in the industrial atmospheric environment were studied by dry-wet cycle immersion test and electrochemical experiments. The results showed that the corrosion rates of TWIP steel gradually decreased with the increase of corrosion time. A layer of corrosion products was formed on the surface of TWIP steel during alternating immersion accelerated corrosion process, whose main components were Fe3O4 and α-FeOOH. With the prolongation of corrosion time, the rust layer on the surface of TWIP steel had a certain protective effect on the steel matrix. The adherent and defect-free electroless nickel–phosphorus (Ni-P) coatings were prepared on TWIP steels. Electrochemical test results showed the corrosion current density of the coating was about six times lower than that of TWIP steel substrate, indicating that the coating effectively improved corrosion resistance of TWIP steel and protected the steel substrate from erosion of corrosive ions. Additionally, the surface microhardness of TWIP steel was significantly increased after electroless Ni-P plating treatment.
- 1 March 2020
- Published by IOP Publishing in Materials Research Express
- Vol. 7 (3) , 036517
Open AccessStudy on corrosion behavior of TWIP steel and properties of surface electroless Ni-P coatings
In this study, the corrosion behavior and corrosion resistance of TWIP (Twinning Induced Plasticity) steels in the industrial atmospheric environment were studied by dry-wet cycle immersion test and electrochemical experiments. The results showed that the corrosion rates of TWIP steel gradually decreased with the increase of corrosion time. A layer of corrosion products was formed on the surface of TWIP steel during alternating immersion accelerated corrosion process, whose main components were Fe3O4 and α-FeOOH. With the prolongation of corrosion time, the rust layer on the surface of TWIP steel had a certain protective effect on the steel matrix. The adherent and defect-free electroless nickel–phosphorus (Ni-P) coatings were prepared on TWIP steels. Electrochemical test results showed the corrosion current density of the coating was about six times lower than that of TWIP steel substrate, indicating that the coating effectively improved corrosion resistance of TWIP steel and protected the steel substrate from erosion of corrosive ions. Additionally, the surface microhardness of TWIP steel was significantly increased after electroless Ni-P plating treatment.
- 12 July 2018
- Published by Springer Nature in Journal of Wuhan University of Technology-Mater. Sci. Ed.
- Vol. 33 (4) , 938-945
Glass Forming Ability and Crystallization Kinetics of Cu-Zr-Al-(Y, Ag) Amorphous Alloy
- 12 July 2018
- Published by Springer Nature in Journal of Wuhan University of Technology-Mater. Sci. Ed.
- Vol. 33 (4) , 938-945
Glass Forming Ability and Crystallization Kinetics of Cu-Zr-Al-(Y, Ag) Amorphous Alloy
- 1 August 2004
- Published by Emerald Publishing in Anti-Corrosion Methods and Materials
- Vol. 51 (4) , 259-265
A study of localised corrosion within occluded cells on a simulated cast iron artefact in chloride solution
The chemical behaviour within the occluded cell of simulated cast iron artefact in 3.5 percent NaCl solution has been investigated by means of a simulated occluded cell. It was observed that the pH value and the amount of Cl− migration in the occluded cell were related to the quantity of passing electric current. Electrochemical techniques were capable of providing information on the behaviour of the cast iron in a simulated occluded cell at various time intervals. The results of potentiodynamic polarisation and impedance measurements indicated that corrosion potentials became more negative and the cast iron was corroded more seriously. SEM micrographs clearly revealed the morphologies of specimens after simulated occluded cell galvanostatic tests for different time intervals at 1 mA/cm2 anodic current density. An auto‐catalysing process was responsible for the enrichment of chloride ions in occluded cell which was confirmed by Energy Dispersive Spectroscopy (EDS).
- 1 August 2004
- Published by Emerald Publishing in Anti-Corrosion Methods and Materials
- Vol. 51 (4) , 259-265
A study of localised corrosion within occluded cells on a simulated cast iron artefact in chloride solution
The chemical behaviour within the occluded cell of simulated cast iron artefact in 3.5 percent NaCl solution has been investigated by means of a simulated occluded cell. It was observed that the pH value and the amount of Cl− migration in the occluded cell were related to the quantity of passing electric current. Electrochemical techniques were capable of providing information on the behaviour of the cast iron in a simulated occluded cell at various time intervals. The results of potentiodynamic polarisation and impedance measurements indicated that corrosion potentials became more negative and the cast iron was corroded more seriously. SEM micrographs clearly revealed the morphologies of specimens after simulated occluded cell galvanostatic tests for different time intervals at 1 mA/cm2 anodic current density. An auto‐catalysing process was responsible for the enrichment of chloride ions in occluded cell which was confirmed by Energy Dispersive Spectroscopy (EDS).