A. E. Sineok
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
A. E. Sineok has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Elena B. Eroshevskaya
Samara State Medical University
2 shared publications - Olga V. Zhukova
Samara State Medical University
2 shared publications - Vladimir M. Malov
Samara State Medical University
2 shared publications A. V. Zolotarev
Samara State Medical University, Research Institute of Eye Diseases Samara T.I. Eroshevskiy regional clinical ophthalmological hospital
1 shared publication- F. Ben Amor
Samara State Medical University
1 shared publication G. A. Nikolaeva
Samara State Medical University, Research Institute of Eye Diseases Samara T.I. Eroshevskiy regional clinical ophthalmological hospital
1 shared publication
Latest Publications
- Open Access
- 9 December 2023
- Published by FSBEI of Higher Education SamSMU of Ministry of Health of the Russian Federation in Aspirantskiy Vestnik Povolzhiya
- Vol. 23 (4) , 20-26
Methods of intraocular lens fixation in complicated cases of lens surgery
There is a growing attention to the lens surgery in complicated cases that require to obtain a good functional result and to minimize the surgical volume. The intraocular lens fixation remains a major problem in complicated cases in lens surgery due to the inadequate capsular support. It is essential to achieve the refractive goal and correct positioning of the intraocular lens both immediately after operation and in the long-term period. The article reviews current available scientific literature of domestic and international authors devoted to the problem of intraocular lens fixation in complicated cases of lens surgery.
- 9 December 2023
- Published by FSBEI of Higher Education SamSMU of Ministry of Health of the Russian Federation in Aspirantskiy Vestnik Povolzhiya
- Vol. 23 (4) , 20-26
Open AccessMethods of intraocular lens fixation in complicated cases of lens surgery
There is a growing attention to the lens surgery in complicated cases that require to obtain a good functional result and to minimize the surgical volume. The intraocular lens fixation remains a major problem in complicated cases in lens surgery due to the inadequate capsular support. It is essential to achieve the refractive goal and correct positioning of the intraocular lens both immediately after operation and in the long-term period. The article reviews current available scientific literature of domestic and international authors devoted to the problem of intraocular lens fixation in complicated cases of lens surgery.
- Open Access
- 9 December 2023
- Published by FSBEI of Higher Education SamSMU of Ministry of Health of the Russian Federation in Aspirantskiy Vestnik Povolzhiya
- Vol. 23 (4) , 10-14
Computer accomodography data for assessing tolerability of optical correction for myopia in near work
Aim – to study the results of computer accomodography in children with myopia optical correction in order to assess the optical correction tolerability during visual work at close distance. Material and methods. The study of myopia optical correction tolerance in near work included 45 children of school age. Subjective and objective research methods were used: a relative accommodation reserve study and computer accomodography. Results. The computer accomodography performed with glasses allowed to determine the nature of the ciliary muscle work in near vision. Computer accomodography data correlated with the value of relative accommodation reserve. Conclusion. We recommend to study the relative accommodation reserve and to use computer accomodography when choosing the optical correction for myopic children.
- 9 December 2023
- Published by FSBEI of Higher Education SamSMU of Ministry of Health of the Russian Federation in Aspirantskiy Vestnik Povolzhiya
- Vol. 23 (4) , 10-14
Open AccessComputer accomodography data for assessing tolerability of optical correction for myopia in near work
Aim – to study the results of computer accomodography in children with myopia optical correction in order to assess the optical correction tolerability during visual work at close distance. Material and methods. The study of myopia optical correction tolerance in near work included 45 children of school age. Subjective and objective research methods were used: a relative accommodation reserve study and computer accomodography. Results. The computer accomodography performed with glasses allowed to determine the nature of the ciliary muscle work in near vision. Computer accomodography data correlated with the value of relative accommodation reserve. Conclusion. We recommend to study the relative accommodation reserve and to use computer accomodography when choosing the optical correction for myopic children.
- Open Access
- 11 December 2018
- Published by Real Time, Ltd. in Russian Ophthalmological Journal
- Vol. 11 (4) , 64-67
Morphological studies of the cadaveric sclera after nonpenetrating sclerotomy by ND: YAG laser
Purpose: to reveal the changes of the morphological structure of cadaveric human sclera after Nd: YAG laser irradiation.Material and methods. Laser pulses (Nd: YAG) (Lumenis) (power 7.0–7.4 mW, pulse duration 4 ns, wavelength 1064 nm) were applied to the sclera of an isolated eyeball at a distance of 4 to 8 mm from the limbus. Three irradiation types were used: one series of single pulses, a series of triple pulses, and a series of six pulses.Results. Incisions created with single pulses showed insignificant surface defects of the sclera. In triple pulses, the defect of the anterior layers of the sclera capture affected 15 % of the scleral thickness, and in six pulses the defect reached 30 % of the scleral thickness.Conclusions. To achieve a punctate hole in the sclera, a single Nd: YAG pulse is insufficient. To obtain a significant depth of scleral incision at least a triple pulse is needed, which must be taken into account in clinical practice as well as in assessing the results of Nd: YAG laser impact on the rigidity of the sclera.
- 11 December 2018
- Published by Real Time, Ltd. in Russian Ophthalmological Journal
- Vol. 11 (4) , 64-67
Open AccessMorphological studies of the cadaveric sclera after nonpenetrating sclerotomy by ND: YAG laser
Purpose: to reveal the changes of the morphological structure of cadaveric human sclera after Nd: YAG laser irradiation.Material and methods. Laser pulses (Nd: YAG) (Lumenis) (power 7.0–7.4 mW, pulse duration 4 ns, wavelength 1064 nm) were applied to the sclera of an isolated eyeball at a distance of 4 to 8 mm from the limbus. Three irradiation types were used: one series of single pulses, a series of triple pulses, and a series of six pulses.Results. Incisions created with single pulses showed insignificant surface defects of the sclera. In triple pulses, the defect of the anterior layers of the sclera capture affected 15 % of the scleral thickness, and in six pulses the defect reached 30 % of the scleral thickness.Conclusions. To achieve a punctate hole in the sclera, a single Nd: YAG pulse is insufficient. To obtain a significant depth of scleral incision at least a triple pulse is needed, which must be taken into account in clinical practice as well as in assessing the results of Nd: YAG laser impact on the rigidity of the sclera.