YTYonatal Mesfin Tefera

Yonatal Mesfin Tefera

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yonatal Mesfin Tefera has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Evaluation of a Web-Based Silica Exposure Risk Assessment Tool in Construction: Data Appraisal and User Trial

    by Sharyn Gaskin, Leonid Turczynowicz, Sarina Subedi, Chandnee Ramkissoon, Yonatal Tefera, Halil Ahmet

    Background: Respirable crystalline silica (RCS) presents persistent health risks in construction, and predictive exposure models offer a potential complement to traditional monitoring. This study evaluated the applicability of the British Columbia Construction Safety Alliance (BCCSA) Silica Control ToolTM for use in the construction sector in Victoria, Australia. Methods: A two-phase evaluation was undertaken. First, a desktop interrogation of the Tool’s underpinning data, statistical model development and documented limitations was performed, including statistical review. Second, a user trial was conducted with 12 Victorian industry stakeholders who completed realistic task scenarios within the Tool and generated Exposure Control Plans (ECPs). Qualitative feedback was obtained through observation and focus group discussion. Results: The interrogation demonstrated that the Tool is built on a large, iteratively improved North American exposure database, with well developed and statistically sound modelling framework; however, its predictive validity has not yet been independently evaluated using Australian exposure data. Stakeholders produced 14 ECPs across diverse silica-generating tasks, showing that the Tool responded sensitively to changes in task parameters and control selections. Thematic analysis identified five key themes: usability, regulatory alignment, clarity of terminology, gaps in task representation, and adherence to the hierarchy of controls. Participants saw strong potential for the Tool but emphasised the need for Australian data integration, clearer definitions, enhanced usability, and localised terminology. Conclusions: The BCCSA Silica Control ToolTM demonstrates a technically robust North American modelling framework and strong stakeholder acceptability, but Australian-specific validation and adaptation are required before adoption in Victoria. Incorporating Australian exposure data, tailoring terminology and ensuring alignment with local legislation are critical next steps.

  • Open Access

    Accuracy of Real-Time Dust Monitors in Quarry Settings: A Pilot Field and Laboratory Evaluation

    by Yonatal Tefera, Chandnee Ramkissoon, Ryan Jurkowski, Shelley Rowett, Hridita Ahmed, Sharyn Gaskin

    Accurate real-time dust monitoring methods are essential in workplaces where exposure to respirable crystalline silica (RCS) presents serious health risks. While real-time monitors are increasingly adopted due to their ability to quickly detect dust-generating activities, concerns remain regarding their accuracy compared to conventional gravimetric methods. This pilot study evaluated the performance of three real-time personal dust monitors: the SidePak™ AM520, Trolex XD1+, and Nanozen DustCount 9000, against a gravimetric reference in both field settings (South Australian quarries) and controlled laboratory environments. Pairwise comparisons of respirable dust (RD) concentrations were conducted across full work shifts. Geometric means from the real-time monitors were regressed against corresponding gravimetric measurements to derive correction coefficients, which were then used to estimate RCS exposure. Agreement between estimated and measured RCS values was assessed using Lin’s Concordance Correlation Coefficient (CCC). Field results revealed inconsistent accuracy for the SidePak™ and Nanozen monitors, with performance varying by task. For example, the SidePak™ overestimated RD by 51% for a truck driver but underestimated levels by up to 48% for other roles. The Trolex XD1+ consistently underestimated RD by 80–89%. All monitors underestimated dust levels under laboratory conditions. However, applying correction coefficients improved agreement with gravimetric data, yielding a high concordance for RCS estimates (Lin’s CCC = 0.89; 95% CI: 0.66–0.97). These findings highlight both the utility and limitations of real-time monitors. Site-specific calibration is essential to enhance their reliability, and further studies with larger datasets are recommended to refine correction factors and improve accuracy of real-time dust monitors.


  • Open Access

    Food grown on fire stations as a potential pathway for firefighters’ exposure to per- and poly-fluoroalkyl substances (PFAS)

    by Yonatal Mesfin Tefera, Sharyn Gaskin, Krystle Mitchell, David Springer, Simon Mills, Dino Pisaniello