WLWangyan Lv

Wangyan Lv

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Wangyan Lv has a total of 6 co-authors. Here are the top co-authors by number of shared publications:

  • Ke Qin Zheng

    Electric Power Research Institute of Guangdong Power Grid Co. Ltd Guangzhou P.R. China

    2 shared publications
  • Zeng Guang Zhang

    Electric Power Research Institute of Guangdong Power Grid Co.Ltd Guangzhou 510080, P. R. China

    2 shared publications
  • Tian Sheng Chen

    Electric Power Research Institute of Guangdong Power Grid Co.Ltd No.8, Shuijungang, Dongfeng East Road Yuexiu Guangzhou 510000 P.R. China

    1 shared publication
  • Wei Su

    Electric Power Research Institute of Guangdong Power Grid Cooperation, Guangzhou, China

    1 shared publication
  • Zengguang Zhang

    Department of Engineering, South China University of Technology, Guangzhou, China

    1 shared publication
  • Zhengchun Liu

    Department of Engineering, South China University of Technology, Guangzhou, China

    1 shared publication

Latest Publications

  • Performance studies of Ag, Ag‐graphite, and Ag‐graphene coatings on Cu substrate for high‐voltage isolation switch

    by Wang Yan Lv, Ke Qin Zheng, Zeng Guang Zhang

    Ag coating, Ag‐graphite composite coating and Ag‐graphene composite coating were prepared on copper surface by electrodeposition. Their microstructure, composition, wear resistance, anti‐corrosion properties, and contact electric resistivity were investigated. The results show that all the coatings have good adhesion with the substrate. The addition of 3.95 at% graphene to the Ag coating could increase its hardness by more than 20%. Compared to the Cu substrate and other two coatings, Ag‐graphene composite coating exhibits the lowest friction coefficient and the smallest wear width. The self‐corrosion current density of Ag‐graphene composite coating in 3.5% NaCl solution is 1.139 μA cm−2, which is also smaller than those of the other coatings. The addition of graphene has little effect on the contact resistance of the coating. The present results indicate that the Ag‐graphene composite coating has great potential for high‐voltage isolation switch application.


  • Feasible preparation and improved properties of Ag‐graphite composite coating for switch contact by cyanide‐free electrodeposition

    by Wangyan Lv, Tian Sheng Chen, Ke Qin Zheng, Zeng Guang Zhang

    A cyanide‐free electrodeposition system was employed to prepare Ag‐graphite composite coatings on Cu substrate for switch contact. The effects of graphite concentration, current density, stirring speed, and plating temperature on the thickness and quality of the composite coating were investigated. The feasibility of cyanide‐free electrodeposition for Ag‐graphite composite was confirmed and the optimized conditions were determined. The growth mechanism of the composite coating was also analyzed. The properties of the composite coating were also investigated compared with Cu substrate and Ag coating. The results show that the Ag‐graphite composite coating has the lowest friction coefficient, moderate corrosion resistance, and relatively low contact resistance. The present results indicate that Ag‐graphite composite coating prepared by cyanide‐free electrodeposition is suitable for disconnector coating.


  • Corrosion of copper exposed to Zhanjiang and Zhuhai atmospheric environments

    by Wei Su, Wangyan Lv, Zhengchun Liu, Zengguang Zhang

    Purpose: The aim of this paper was to study the initial corrosion behavior of copper in the substations of Zhanjiang and Zhuhai. Design/methodology/approach: The copper exposed at the substation of Guangdong coastal region in southern China for up to 12 months. The rust layer formed on the copper has been examined by scanning electron microscopy, X-ray energy spectrum, X-ray diffraction and electrochemical polarization techniques. Findings: The corrosion weight loss of copper at Zhanjiang exposure site is a little more serious than that at Zhuhai exposure site in every exposure period. The corrosion products of copper have different changes in color and composition at the two exposure sites. The tensile strength of copper has a slight decrease after one-year exposure. Originality/value: The atmospheric exposure experiments of copper in the substations of Zhanjiang and Zhuhai have been adopted for the first time. The corrosion behavior of copper was investigated, and it can provide reference for material selection of the substation.