Leslie Kojo Norvihoho
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Leslie Kojo Norvihoho has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Jing Yin
Chongqing University,School of Electrical Engineering,Chongqing,China
6 shared publications - Zhi-Fu Zhou
State Key Laboratory of Multiphase Flow in Power Engineering, Xi’an Jiaotong University, Xi’an 710049, China
6 shared publications - Hai-Tao Yu3 shared publications
Qi-Di Wang
3 shared publicationsBin Chen
2 shared publications- Shu-Qin Xue2 shared publications
Latest Publications
- 1 February 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (2)
Infectious cough droplet dynamics in a makeshift hospital isolation ward
The COVID-19 pandemic highlighted the need for rapidly deployable healthcare facilities, leading to increased use of modular construction methods. Nonetheless, knowledge about airflow patterns and the spread of bioaerosols in these wards remains insufficient, potentially heightening the risk of cross-infection among healthcare workers and patients. This paper presents a ventilation design for a modular negative-pressure ward aimed at reducing the spread of infectious particles. We investigate the effects of various ventilation designs, patient postures (sitting and supine), and air changes per hour (ACH) on the spread of infectious cough droplets in an airborne infection isolation room using large eddy simulation and the Eulerian–Lagrangian model. Findings show that ceiling exhaust grilles (design 2) resulted in the lowest radial dispersion (3.64 m) at 12 ACH, while sidewall exhausts (baseline) performed best at higher ACH levels. Seated patients had quicker droplet evaporation compared to those in a supine position. The best setups for reducing droplet survival included exhaust grilles at the bed's bottom and ceiling, maintaining a minimum of 12 ACH. Cases 5 and 13, with grilles over the patient's head and at the bed's bottom, showed the lowest concentrations of DPM, under 0.008 km−3 near the source and less than 0.001 km−3 mid-room. Sitting posture consistently led to lower DPM concentrations. This research emphasizes the critical role of exhaust placement in reducing droplet re-circulation and transmission risks, ultimately contributing to improved ventilation strategies and infection control in AII rooms.
- 1 February 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (2)
Infectious cough droplet dynamics in a makeshift hospital isolation ward
The COVID-19 pandemic highlighted the need for rapidly deployable healthcare facilities, leading to increased use of modular construction methods. Nonetheless, knowledge about airflow patterns and the spread of bioaerosols in these wards remains insufficient, potentially heightening the risk of cross-infection among healthcare workers and patients. This paper presents a ventilation design for a modular negative-pressure ward aimed at reducing the spread of infectious particles. We investigate the effects of various ventilation designs, patient postures (sitting and supine), and air changes per hour (ACH) on the spread of infectious cough droplets in an airborne infection isolation room using large eddy simulation and the Eulerian–Lagrangian model. Findings show that ceiling exhaust grilles (design 2) resulted in the lowest radial dispersion (3.64 m) at 12 ACH, while sidewall exhausts (baseline) performed best at higher ACH levels. Seated patients had quicker droplet evaporation compared to those in a supine position. The best setups for reducing droplet survival included exhaust grilles at the bed's bottom and ceiling, maintaining a minimum of 12 ACH. Cases 5 and 13, with grilles over the patient's head and at the bed's bottom, showed the lowest concentrations of DPM, under 0.008 km−3 near the source and less than 0.001 km−3 mid-room. Sitting posture consistently led to lower DPM concentrations. This research emphasizes the critical role of exhaust placement in reducing droplet re-circulation and transmission risks, ultimately contributing to improved ventilation strategies and infection control in AII rooms.
- 1 November 2024
- Published by AIP Publishing in Physics of Fluids
- Vol. 36 (11)
The effects of ventilation layout on cough droplet dynamics relating to seasonal influenza
The primary aim of this paper is to investigate airborne virus transmission in a typical meeting room relating to the heating, ventilation, and air conditioning (A.C.) systems. While the installation of 4-way cassette A.C. systems in offices and meeting rooms has become increasingly common, their efficiency in mitigating short-range airborne virus spread remains poorly understood. Addressing this gap is critical in the post-pandemic era, where understanding the limitations of various ventilation systems is paramount for public health. We systematically compare the performance of the 4-way cassette A.C., various configurations of mixing and displacement ventilation systems, and natural ventilation in controlling the spread of respiratory viruses. Our research uniquely integrates evaporation models to accurately simulate cough clouds' multiphase behavior under both quiescent and thermally influenced conditions. The study benchmarks these systems against two widely recognized ventilation standards (i.e., 5 air changes per hour and 10 l/s per person), offering evidence-based insights applicable across diverse indoor settings. Our findings reveal significant thermal effects in the quiescent case, resulting in 32.3%, 54.3%, and 8.0% changes in the axial, vertical, and lateral spread of the virus-laden droplets, respectively. Notably, the 0.5 m/s 4-way cassette A.C. system demonstrated superior performance, reducing the axial spread by 29.6% compared to other mechanical ventilation configurations. Furthermore, the role of exhaust outlets or doors was found to be critical in shaping the spread pattern in natural ventilation scenarios. This work can offer practical guidance to office workers, engineers, and public health officials on enhancing indoor airborne infection control.
- 1 November 2024
- Published by AIP Publishing in Physics of Fluids
- Vol. 36 (11)
The effects of ventilation layout on cough droplet dynamics relating to seasonal influenza
The primary aim of this paper is to investigate airborne virus transmission in a typical meeting room relating to the heating, ventilation, and air conditioning (A.C.) systems. While the installation of 4-way cassette A.C. systems in offices and meeting rooms has become increasingly common, their efficiency in mitigating short-range airborne virus spread remains poorly understood. Addressing this gap is critical in the post-pandemic era, where understanding the limitations of various ventilation systems is paramount for public health. We systematically compare the performance of the 4-way cassette A.C., various configurations of mixing and displacement ventilation systems, and natural ventilation in controlling the spread of respiratory viruses. Our research uniquely integrates evaporation models to accurately simulate cough clouds' multiphase behavior under both quiescent and thermally influenced conditions. The study benchmarks these systems against two widely recognized ventilation standards (i.e., 5 air changes per hour and 10 l/s per person), offering evidence-based insights applicable across diverse indoor settings. Our findings reveal significant thermal effects in the quiescent case, resulting in 32.3%, 54.3%, and 8.0% changes in the axial, vertical, and lateral spread of the virus-laden droplets, respectively. Notably, the 0.5 m/s 4-way cassette A.C. system demonstrated superior performance, reducing the axial spread by 29.6% compared to other mechanical ventilation configurations. Furthermore, the role of exhaust outlets or doors was found to be critical in shaping the spread pattern in natural ventilation scenarios. This work can offer practical guidance to office workers, engineers, and public health officials on enhancing indoor airborne infection control.
- 1 June 2024
- Published by AIP Publishing in Physics of Fluids
- Vol. 36 (6)
Experimental study on evaporation characteristics of methyl oleate droplet across critical pressure and temperature environments
Droplet evaporation plays a crucial role in many engineering situations involving the transport and computation of sprays. It becomes a challenging issue in fluid dynamics if vaporization occurs in high temperature and pressure environments, especially across critical conditions due to the uncertainty of interactions between droplet and ambient gas. In this study, an experimental system capable of recording droplet morphology and temperature in high temperature and pressure conditions was constructed. The evaporation characteristics of methyl oleate droplet with initial diameters between 0.9 and 1.1 mm was investigated at various ambient pressures (atmospheric to 2.0 MPa) and temperatures (573–873 K). The results revealed that the evaporation process of methyl oleate droplet consisted of three stages: the transient heating stage, steady state evaporation stage, and slow evaporation stage. The third stage occurred due to the gradual decomposition of methyl oleate in the later period of evaporation. The lower the ambient temperature, the earlier the third stage appeared. At lower pressure conditions, the evaporation rate and lifetime of the droplet exhibited a relatively gradual variation with temperature. However, at higher pressure conditions, both the evaporation rate and lifetime changed exponentially with temperature. The influence of pressure on the evaporation rate depended greatly on the ambient temperature and the state of the droplet. In general, droplet across the critical pressure experienced a significant reduction in the evaporation rate. However, this reduction disappears once the ambient temperature is far beyond the critical temperature.
- 1 June 2024
- Published by AIP Publishing in Physics of Fluids
- Vol. 36 (6)
Experimental study on evaporation characteristics of methyl oleate droplet across critical pressure and temperature environments
Droplet evaporation plays a crucial role in many engineering situations involving the transport and computation of sprays. It becomes a challenging issue in fluid dynamics if vaporization occurs in high temperature and pressure environments, especially across critical conditions due to the uncertainty of interactions between droplet and ambient gas. In this study, an experimental system capable of recording droplet morphology and temperature in high temperature and pressure conditions was constructed. The evaporation characteristics of methyl oleate droplet with initial diameters between 0.9 and 1.1 mm was investigated at various ambient pressures (atmospheric to 2.0 MPa) and temperatures (573–873 K). The results revealed that the evaporation process of methyl oleate droplet consisted of three stages: the transient heating stage, steady state evaporation stage, and slow evaporation stage. The third stage occurred due to the gradual decomposition of methyl oleate in the later period of evaporation. The lower the ambient temperature, the earlier the third stage appeared. At lower pressure conditions, the evaporation rate and lifetime of the droplet exhibited a relatively gradual variation with temperature. However, at higher pressure conditions, both the evaporation rate and lifetime changed exponentially with temperature. The influence of pressure on the evaporation rate depended greatly on the ambient temperature and the state of the droplet. In general, droplet across the critical pressure experienced a significant reduction in the evaporation rate. However, this reduction disappears once the ambient temperature is far beyond the critical temperature.
- Open Access
- 1 February 2024
- Published by AIP Publishing in Physics of Fluids
- Vol. 36 (2)
Evaporation characteristics of cis-1,1,1,4,4,4-hexafluoro-2-butene (R1336mzz(Z)) droplet in high pressure and temperature environments
Cis-1,1,1,4,4,4-hexafluoro-2-butene (R1336mzz(Z)) has emerged as an exceptionally promising low-global-warming-potential (GWP) refrigerant, ideal for spray cooling systems in the thermal management of electronic components. Research on the evaporation characteristics of an individual isolated cryogen droplet excludes uncertainties caused by droplet collisions and fusion, thereby laying the foundation for spray cooling. In this paper, a theoretical model for single R1336mzz (Z) droplet evaporation considering the effect of natural convection in a high pressure and temperature environment is proposed. The newly proposed model is validated by comparing the predicted results of the R1336mzz(Z) droplet evaporation with experimental data. Then, the effects of environmental temperature (323–523 K) and pressure (1–20 bar) on the R1336mzz(Z) droplet evaporation are investigated. The results reveal that the effect of increasing the ambient pressure on the droplet lifetime of R1336mzz(Z) undergoes a transition from deceleration to acceleration. Elevated temperature can promote droplet evaporation; however, the promoting effect of increasing the ambient temperature on droplet evaporation will be weakened in high-pressure cases. Increasing the ambient pressure and temperature both can enhance the heat transfer from the environment to the droplet through natural convection, while increasing the pressure greatly inhibits the molecular diffusion during droplet evaporation. Thus, the total evaporation rate depends on the competing effects of these two factors. In addition, the trend of the droplet temperature variation could differ based on droplet initial temperatures, ambient temperatures, and pressures. An increase in the ambient temperature or pressure corresponds to an increase in the droplet equilibrium temperature (Tequ). However, Tequ is almost independent of the droplet initial size and temperature.
- 1 February 2024
- Published by AIP Publishing in Physics of Fluids
- Vol. 36 (2)
Open AccessEvaporation characteristics of cis-1,1,1,4,4,4-hexafluoro-2-butene (R1336mzz(Z)) droplet in high pressure and temperature environments
Cis-1,1,1,4,4,4-hexafluoro-2-butene (R1336mzz(Z)) has emerged as an exceptionally promising low-global-warming-potential (GWP) refrigerant, ideal for spray cooling systems in the thermal management of electronic components. Research on the evaporation characteristics of an individual isolated cryogen droplet excludes uncertainties caused by droplet collisions and fusion, thereby laying the foundation for spray cooling. In this paper, a theoretical model for single R1336mzz (Z) droplet evaporation considering the effect of natural convection in a high pressure and temperature environment is proposed. The newly proposed model is validated by comparing the predicted results of the R1336mzz(Z) droplet evaporation with experimental data. Then, the effects of environmental temperature (323–523 K) and pressure (1–20 bar) on the R1336mzz(Z) droplet evaporation are investigated. The results reveal that the effect of increasing the ambient pressure on the droplet lifetime of R1336mzz(Z) undergoes a transition from deceleration to acceleration. Elevated temperature can promote droplet evaporation; however, the promoting effect of increasing the ambient temperature on droplet evaporation will be weakened in high-pressure cases. Increasing the ambient pressure and temperature both can enhance the heat transfer from the environment to the droplet through natural convection, while increasing the pressure greatly inhibits the molecular diffusion during droplet evaporation. Thus, the total evaporation rate depends on the competing effects of these two factors. In addition, the trend of the droplet temperature variation could differ based on droplet initial temperatures, ambient temperatures, and pressures. An increase in the ambient temperature or pressure corresponds to an increase in the droplet equilibrium temperature (Tequ). However, Tequ is almost independent of the droplet initial size and temperature.
- Open Access
- 1 January 2024
- Published by AIP Publishing in Physics of Fluids
- Vol. 36 (1)
The effects of desk-partition layout on cough droplet dynamics relating to seasonal influenza
The use of physical dividers as control measures for short-range viral transmission in indoor settings has gained increasing attention. However, the understanding regarding their correct usage under different seating arrangements is incomplete. In this study, we focused on assessing the effectiveness of physical dividers in impeding the transient transmission of cough droplets in three representative layouts using the large-eddy simulation technique with the Eulerian–Lagrangian model. We computationally also investigated the effects of ventilation on viral droplet transmission under three representative desk-divider layouts. The ventilation approach was tested using two different ventilation rates (1.0 and 1.8 m/s). A comparative analysis of the ventilation flow fields, topologies, and particle directions has been studied. The findings indicate that the sitting arrangements, ventilation rates, and partition layouts play a significant role in designing effective control measures for indoor infection under the office setup considered. The protected occupied zone ventilation (POV) worked best in situations of low ventilation (1.0 m/s) for cross-partition in protecting the three healthy persons. In addition, the POV performed well for low (1.0 m/s) and high (1.8 m/s) ventilation rates for face-to-face layout. The side-by-side configuration performed poorly for the POV considered in protecting the healthy person seated directly opposite the infected person. The numerical predictions may be used to validate other experimental studies and educate office workers and engineers on indoor airborne infection control.
- 1 January 2024
- Published by AIP Publishing in Physics of Fluids
- Vol. 36 (1)
Open AccessThe effects of desk-partition layout on cough droplet dynamics relating to seasonal influenza
The use of physical dividers as control measures for short-range viral transmission in indoor settings has gained increasing attention. However, the understanding regarding their correct usage under different seating arrangements is incomplete. In this study, we focused on assessing the effectiveness of physical dividers in impeding the transient transmission of cough droplets in three representative layouts using the large-eddy simulation technique with the Eulerian–Lagrangian model. We computationally also investigated the effects of ventilation on viral droplet transmission under three representative desk-divider layouts. The ventilation approach was tested using two different ventilation rates (1.0 and 1.8 m/s). A comparative analysis of the ventilation flow fields, topologies, and particle directions has been studied. The findings indicate that the sitting arrangements, ventilation rates, and partition layouts play a significant role in designing effective control measures for indoor infection under the office setup considered. The protected occupied zone ventilation (POV) worked best in situations of low ventilation (1.0 m/s) for cross-partition in protecting the three healthy persons. In addition, the POV performed well for low (1.0 m/s) and high (1.8 m/s) ventilation rates for face-to-face layout. The side-by-side configuration performed poorly for the POV considered in protecting the healthy person seated directly opposite the infected person. The numerical predictions may be used to validate other experimental studies and educate office workers and engineers on indoor airborne infection control.
- Open Access
- 1 August 2023
- Published by AIP Publishing in Physics of Fluids
- Vol. 35 (8)
Dispersion of expectorated cough droplets with seasonal influenza in an office
We do not fully grasp viral droplet transmission processes in ventilated interior environments. The core focus of our research is to investigate the effectiveness of the protected occupied zone ventilation (POV) through computational fluid dynamics models in a simplified office setting. The large-eddy simulation technique with the Eulerian–Lagrangian model was implemented to address complicated indoor processes such as turbulence, flow–aerosol interaction, and ventilation impact. We computationally investigated the effects of desk partitions and the POV on cough droplets in an office. The ventilation approach was tested using two distinct exhaust layouts and four different ventilation rates (1.0, 1.2, 1.5, and 1.8 m/s). A comparative analysis of the ventilation flow fields, topologies, and particle directions has been studied. The findings indicate that the plane jet's ventilation rates influence the protected occupied zone ventilation performance. The ventilation rates distributed the virus droplets around the room, but compared to the up-exhaust cases, the down-exhaust cases appeared to have better shielded the healthy person. This pattern could indicate that the placement of the exhaust outlet in ventilation systems significantly influences indoor aerosol dispersion. The results also show that substantial flow streams may carry tiny particles (≤70 μm) throughout their path. Large particles (≥100 μm) could not go far in cough gas clouds. Most viral particles deposit on solid surfaces in various work sites per specific ventilation rates. Office workers need to be very cautious around these hazardous areas.
- 1 August 2023
- Published by AIP Publishing in Physics of Fluids
- Vol. 35 (8)
Open AccessDispersion of expectorated cough droplets with seasonal influenza in an office
We do not fully grasp viral droplet transmission processes in ventilated interior environments. The core focus of our research is to investigate the effectiveness of the protected occupied zone ventilation (POV) through computational fluid dynamics models in a simplified office setting. The large-eddy simulation technique with the Eulerian–Lagrangian model was implemented to address complicated indoor processes such as turbulence, flow–aerosol interaction, and ventilation impact. We computationally investigated the effects of desk partitions and the POV on cough droplets in an office. The ventilation approach was tested using two distinct exhaust layouts and four different ventilation rates (1.0, 1.2, 1.5, and 1.8 m/s). A comparative analysis of the ventilation flow fields, topologies, and particle directions has been studied. The findings indicate that the plane jet's ventilation rates influence the protected occupied zone ventilation performance. The ventilation rates distributed the virus droplets around the room, but compared to the up-exhaust cases, the down-exhaust cases appeared to have better shielded the healthy person. This pattern could indicate that the placement of the exhaust outlet in ventilation systems significantly influences indoor aerosol dispersion. The results also show that substantial flow streams may carry tiny particles (≤70 μm) throughout their path. Large particles (≥100 μm) could not go far in cough gas clouds. Most viral particles deposit on solid surfaces in various work sites per specific ventilation rates. Office workers need to be very cautious around these hazardous areas.