Gayaneh Petrossian
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Gayaneh Petrossian has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Fabio Cicoira
Department of Chemical Engineering Polytechnique Montréal Montréal Quebec Canada
3 shared publications Floriane Miquet-Westphal
Department of Chemical Engineering, Polytechnique Montreal, Montreal H3T 1J4, Canada
2 shared publications- Biporjoy Sarkar
Department of Chemical Engineering, Polytechnique Montreal, Montreal H3T 1J4, Canada
1 shared publication Eric Quenneville
Biomomentum Inc. Laval Montreal Canada
1 shared publicationFederico Ursino
Dipartimento di Fisica e Astronomia “Ettore Majorana” Università degli studi di Catania Catania Italy
1 shared publicationJiaxin Fan
Department of Chemical Engineering, Polytechnique Montreal, Montreal H3T 1J4, Canada
1 shared publication
Latest Publications
- Open Access
- 13 October 2026
- Published by Wiley in ChemistryEurope
- Vol. 4 (10)
EDOT‐Acid Enables Stable PEDOT Coatings on Ni–P Electrodes Through Interfacial Molecular Interactions
The stability of conducting polymer coatings on metallic substrates is often limited by poor interfacial adhesion, which can lead to delamination and degradation of electrochemical performance. Here, we report low‐impedance printed circuit board (PCB) electrodes based on electrodeposited poly(3,4‐ethylenedioxythiophene) (PEDOT) coatings on gold and electroless nickel–phosphorus (Ni–P) substrates. While PEDOT is widely used to reduce electrode impedance, poor adhesion on metallic substrates, particularly Ni–P, limits coating stability and long‐term performance. To address this limitation, we introduce an interfacial modification strategy based on EDOT‐acid pretreatment, which acts as a molecular adhesion promoter between the metal surface and the electrodeposited PEDOT film. X‐ray photoelectron spectroscopy (XPS) confirms the chemisorption of EDOT‐acid on both Au and Ni–P surfaces through carboxylate bonding and metal–sulfur interactions. Atomic force microscopy force–displacement measurements reveal a substantial increase in local surface adhesion after EDOT‐acid treatment, with adhesion forces increasing by approximately 2.5× on Au and nearly threefold on Ni–P substrates. Electrochemical measurements show that the PEDOT coatings significantly reduce electrode impedance and improve charge storage capacity. The EDOT‐acid pretreatment enables stable PEDOT coatings that remain intact after prolonged sonication, particularly on Ni–P, supporting its use as a cost‐effective alternative to gold.
- 13 October 2026
- Published by Wiley in ChemistryEurope
- Vol. 4 (10)
Open AccessEDOT‐Acid Enables Stable PEDOT Coatings on Ni–P Electrodes Through Interfacial Molecular Interactions
The stability of conducting polymer coatings on metallic substrates is often limited by poor interfacial adhesion, which can lead to delamination and degradation of electrochemical performance. Here, we report low‐impedance printed circuit board (PCB) electrodes based on electrodeposited poly(3,4‐ethylenedioxythiophene) (PEDOT) coatings on gold and electroless nickel–phosphorus (Ni–P) substrates. While PEDOT is widely used to reduce electrode impedance, poor adhesion on metallic substrates, particularly Ni–P, limits coating stability and long‐term performance. To address this limitation, we introduce an interfacial modification strategy based on EDOT‐acid pretreatment, which acts as a molecular adhesion promoter between the metal surface and the electrodeposited PEDOT film. X‐ray photoelectron spectroscopy (XPS) confirms the chemisorption of EDOT‐acid on both Au and Ni–P surfaces through carboxylate bonding and metal–sulfur interactions. Atomic force microscopy force–displacement measurements reveal a substantial increase in local surface adhesion after EDOT‐acid treatment, with adhesion forces increasing by approximately 2.5× on Au and nearly threefold on Ni–P substrates. Electrochemical measurements show that the PEDOT coatings significantly reduce electrode impedance and improve charge storage capacity. The EDOT‐acid pretreatment enables stable PEDOT coatings that remain intact after prolonged sonication, particularly on Ni–P, supporting its use as a cost‐effective alternative to gold.
- Open Access
- 3 April 2025
- Published by IOP Publishing in Flexible and Printed Electronics
- Vol. 10 (2) , 025002
Electromagnetic interference shielding in soft, lightweight, and flexible conducting polymer-based sponges
Developing highly efficient, low-density, and mechanically flexible electromagnetic interference (EMI) shielding materials based on conducting polymers has gained significant momentum for suppressing electromagnetic pollution. In our work, we investigated the EMI shielding behavior of uniaxially compressible sponges using the conducting polymer poly(3,4-ethylenedixoythiophene) polystyrene sulfonate (PEDOT:PSS) in the X-band frequency range of 8–12.4 GHz. Two types of PEDOT:PSS sponges, type-I with glycerol and (3-glycidyloxypropyl) trimethoxy silane and type-II containing glycerol and polyethylene glycol, were prepared by freeze-drying method. Both sponges exhibited a rapid decrease in resistance for the initial compressive strain of less than 20%, which stabilized at higher compressive strains. This behavior was likely due to the complex 3D porous structures of the sponges and was linked to the creation of new electrical contacts due to pore collapse under compressive strain. The enhanced electrical conductivity, porous structure, large surface area, and many internal surfaces resulted in exceptional EMI shielding for PEDOT:PSS sponges, achieving shielding values as high as 44 dB and 72 dB, respectively. The EMI shielding in these materials was primarily dominated by the reflection process. This work contributes to developing flexible and high-efficiency EMI shielding materials for flexible electronic applications in the future.
- 3 April 2025
- Published by IOP Publishing in Flexible and Printed Electronics
- Vol. 10 (2) , 025002
Open AccessElectromagnetic interference shielding in soft, lightweight, and flexible conducting polymer-based sponges
Developing highly efficient, low-density, and mechanically flexible electromagnetic interference (EMI) shielding materials based on conducting polymers has gained significant momentum for suppressing electromagnetic pollution. In our work, we investigated the EMI shielding behavior of uniaxially compressible sponges using the conducting polymer poly(3,4-ethylenedixoythiophene) polystyrene sulfonate (PEDOT:PSS) in the X-band frequency range of 8–12.4 GHz. Two types of PEDOT:PSS sponges, type-I with glycerol and (3-glycidyloxypropyl) trimethoxy silane and type-II containing glycerol and polyethylene glycol, were prepared by freeze-drying method. Both sponges exhibited a rapid decrease in resistance for the initial compressive strain of less than 20%, which stabilized at higher compressive strains. This behavior was likely due to the complex 3D porous structures of the sponges and was linked to the creation of new electrical contacts due to pore collapse under compressive strain. The enhanced electrical conductivity, porous structure, large surface area, and many internal surfaces resulted in exceptional EMI shielding for PEDOT:PSS sponges, achieving shielding values as high as 44 dB and 72 dB, respectively. The EMI shielding in these materials was primarily dominated by the reflection process. This work contributes to developing flexible and high-efficiency EMI shielding materials for flexible electronic applications in the future.
- 26 July 2023
- Published by American Chemical Society (ACS) in ACS Applied Bio Materials
- Vol. 6 (8) , 3019-3032
Advances in Electrode Materials for Scalp, Forehead, and Ear EEG: A Mini-Review
Electroencephalogram (EEG) records the electrical activity of neurons in the cerebral cortex and is used extensively to diagnose, treat, and monitor psychiatric and neurological conditions. Reliable contact between the skin and the electrodes is essential for achieving consistency and for obtaining electroencephalographic information. There has been an increasing demand for effective equipment and electrodes to overcome the time-consuming and cumbersome application of traditional systems. Recently, ear-centered EEG has met with growing interest since it can provide good signal quality due to the proximity of the ear to the brain. In addition, it can facilitate mobile and unobtrusive usage due to its smaller size and ease of use, since it can be used without interfering with the patient's daily activities. The purpose of this mini-review is to first introduce the broad range of electrodes used in conventional (scalp) EEG and subsequently discuss the state-of-the-art literature about around- and in-the-ear EEG.
- 26 July 2023
- Published by American Chemical Society (ACS) in ACS Applied Bio Materials
- Vol. 6 (8) , 3019-3032
Advances in Electrode Materials for Scalp, Forehead, and Ear EEG: A Mini-Review
Electroencephalogram (EEG) records the electrical activity of neurons in the cerebral cortex and is used extensively to diagnose, treat, and monitor psychiatric and neurological conditions. Reliable contact between the skin and the electrodes is essential for achieving consistency and for obtaining electroencephalographic information. There has been an increasing demand for effective equipment and electrodes to overcome the time-consuming and cumbersome application of traditional systems. Recently, ear-centered EEG has met with growing interest since it can provide good signal quality due to the proximity of the ear to the brain. In addition, it can facilitate mobile and unobtrusive usage due to its smaller size and ease of use, since it can be used without interfering with the patient's daily activities. The purpose of this mini-review is to first introduce the broad range of electrodes used in conventional (scalp) EEG and subsequently discuss the state-of-the-art literature about around- and in-the-ear EEG.