Shuntaro Takazawa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Shuntaro Takazawa has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Haruki Nishino
RIKEN SPring-8 Center, 1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5148, Japan
1 shared publication - Hideshi Uematsu
International Center for Synchrotron Radiation Innovation Smart (SRIS), Tohoku University, 2-1-1 Katahira, Aoba-ku, Sendai 980-8577, Japan
1 shared publication - Kazuo Kobayashi
RIKEN SPring-8 Center, 1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5148, Japan
1 shared publication - Kyosuke Ozaki
RIKEN SPring-8 Center, 1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5148, Japan
1 shared publication - Masaki Abe
International Center for Synchrotron Radiation Innovation Smart (SRIS), Tohoku University, 2-1-1 Katahira, Aoba-ku, Sendai 980-8577, Japan
1 shared publication - Nozomu Ishiguro
International Center for Synchrotron Radiation Innovation Smart (SRIS), Tohoku University, 2-1-1 Katahira, Aoba-ku, Sendai 980-8577, Japan
1 shared publication
Latest Publications
- Open Access
- 1 August 2023
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 30 (5) , 989-994
High-resolution and high-sensitivity X-ray ptychographic coherent diffraction imaging using the CITIUS detector
Ptychographic coherent diffraction imaging (PCDI) is a synchrotron X-ray microscopy technique that provides high spatial resolution and a wide field of view. To improve the performance of PCDI, the performance of the synchrotron radiation source and imaging detector should be improved. In this study, ptychographic diffraction pattern measurements using the CITIUS high-speed X-ray image detector and the corresponding image reconstruction are reported. X-rays with an energy of 6.5 keV were focused by total reflection focusing mirrors, and a flux of ∼2.6 × 1010 photons s−1 was obtained at the sample plane. Diffraction intensity data were collected at up to ∼250 Mcounts s−1 pixel−1 without saturation of the detector. Measurements of tantalum test charts and silica particles and the reconstruction of phase images were performed. A resolution of ∼10 nm and a phase sensitivity of ∼0.01 rad were obtained. The CITIUS detector can be applied to the PCDI observation of various samples using low-emittance synchrotron radiation sources and to the stability evaluation of light sources.
- 1 August 2023
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 30 (5) , 989-994
Open AccessHigh-resolution and high-sensitivity X-ray ptychographic coherent diffraction imaging using the CITIUS detector
Ptychographic coherent diffraction imaging (PCDI) is a synchrotron X-ray microscopy technique that provides high spatial resolution and a wide field of view. To improve the performance of PCDI, the performance of the synchrotron radiation source and imaging detector should be improved. In this study, ptychographic diffraction pattern measurements using the CITIUS high-speed X-ray image detector and the corresponding image reconstruction are reported. X-rays with an energy of 6.5 keV were focused by total reflection focusing mirrors, and a flux of ∼2.6 × 1010 photons s−1 was obtained at the sample plane. Diffraction intensity data were collected at up to ∼250 Mcounts s−1 pixel−1 without saturation of the detector. Measurements of tantalum test charts and silica particles and the reconstruction of phase images were performed. A resolution of ∼10 nm and a phase sensitivity of ∼0.01 rad were obtained. The CITIUS detector can be applied to the PCDI observation of various samples using low-emittance synchrotron radiation sources and to the stability evaluation of light sources.