FRFrancesca Rodino

Francesca Rodino

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Francesca Rodino has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • From Single-Drug to Cocktail Monitoring: Biosensors for Multi-Drug Detection in Precision Oncology

    by Francesca Rodino, Sandro Carrara

    Therapeutic drug monitoring in precision oncology requires the simultaneous detection of multiple chemotherapeutic agents, as treatments are typically administered as drug combinations rather than single compounds. However, existing sensing systems are often limited to single-analyte detection or require complex multi-electrode configurations, making them unsuitable for point-of-care applications. This work presents a dual-channel electrochemical biosensor platform capable of detecting up to five chemotherapeutic drugs using only two working electrodes. The system combines non-enzymatic detection of electroactive drugs with cytochrome P450-based enzymatic sensing of non-electroactive compounds, enabling simultaneous multi-drug monitoring in a compact platform suitable for point-of-care therapeutic drug monitoring in precision oncology.

  • Open Access

    Long-term performance of low-cost free chlorine sensors to monitor on-site water reuse

    by Gaétan Herold, Francesca Rodino, Antonin Prévoteau, Sandro Carrara, Eva Reynaert

    Water scarcity increasingly challenges the supply of sufficient quantities of safe water for human consumption. On-site water reuse systems can contribute to mitigating the effects of water scarcity by closing water cycles locally. However, broader adoption of on-site water reuse is constrained by the high cost of water quality monitoring. This work demonstrates the successful design and validation of low-cost chlorine amperometric sensors for long-term monitoring using Prussian blue-coated screen-printed carbon electrodes. The study is relevant for practice, as testing was conducted in a water reuse system treating real greywater and municipal wastewater. The sensors achieved a relatively stable sensitivity of 8.55 ± 1.19 μA/(ppm⋅cm2) for hypochlorous acid after a 3-day stabilization period and maintained a sensitivity of 3.72 μA/(ppm⋅cm2) after 1 month. The sensors exhibited a linear dynamic range from 0.3 to 5 ppm for hypochlorous acid (R2 > 0.95). This study highlights the potential of Prussian blue-coated sensors as a practical solution for continuous chlorine monitoring in on-site water reuse applications. The findings encourage further research to improve durability and scalability to optimise the sensors for applications where low-cost sensing solutions are needed without personnel on-site for regular sensor maintenance and calibration.


  • Open Access

    Optimized Quantification of Multiple Drug Concentrations by WeightedMSE With Machine Learning on Electrochemical Sensor

    by Tatsunori Matsumoto, Lin Du, Francesca Rodino, Yann Thoma, Chinthaka Premachandra, Sandro Carrara

    Quantification of multiple drugs is of great importance and urgently needed in therapeutic drug monitoring (TDM) and personalized therapy. Especially, based on cyclic voltammograms (CV) obtained by electrochemical sensors, the use of artificial neural networks (ANNs) has been widely attempted in the accurate quantification of drug concentrations, enabling the development of point-of-care and potentially system-level wearable devices. However, most of the work only considers the accuracy of how the predicted value is close to the actual value, which does not consider whether the predicted drug concentration is underestimated. In practical drug quantification, potential toxicity due to overexposure with underestimated quantification can lead to endangering the patient's body. Therefore, avoiding underestimating the concentration of drugs based on existing quantification models is required and necessary to optimize the conventional loss function at the output stage of ANN. In this paper, a novel loss function based on Mean Squared Error (MSE), WeightedMSE, is proposed for avoiding underestimated quantification. It can be changed flexibly by adjusting parameters in order to adapt the acceptable overestimation range corresponding to the different types of drugs. A simulated dataset and a real dataset of Etoposide (ETO) and Methotrexate (MTX) are used as drug models, demonstrating that the proposed method can avoid underestimation in predicted values by over 98% in quantifying the concentration of multiple drugs and showing significant effectiveness for the development of point-of-care and wearable monitoring systems.


  • A Novel Microfluidic System for Capacitive Detection Via Magnetophoretic Separation of Malaria-Infected Red Blood Cells

    by Amirmahdi Tavakolidakhrabadi, Théo Domange, Clémentine Naım, Francesca Rodino, Ali Meimandi, Cédric Bessire, Sandro Carrara

    Malaria continues to pose a significant global health challenge, with substantial impediments arising from the need for more reliable, effective, and economically viable diagnostic tools, particularly for early detection. This research introduces a novel microfluidic device designed for malaria-diagnostics through the detection of hemozoin (Hz), a prevalent biomarker for the disease. Our methodology involves the collection of a minimal blood sample, which is subsequently processed through a microfluidic system. This system exploits the paramagnetic properties of Hz to isolate infected blood cells using magnetophoretic separation. The detection process employs a relative capacitive measurement technique capable of quantifying Hz concentrations ranging from 417 $fM$ to 17 $pM$ , facilitating and enhancing malaria diagnosis. Simulations results confirm the efficacy of our device in providing a rapid, cost-effective, and readily producible diagnostic solution. This research demonstrates the potential of integrating advanced microfluidic technology and sensitive detection systems into a compact, portable unit, offering significant improvements over existing malaria diagnostic tools.


  • Identification and Quantification of Multiple Drugs by Machine Learning on Electrochemical Sensors for Therapeutic Drug Monitoring

    by Lin Du, Francesca Rodino, Yann Thoma, Sandro Carrara

    Electrochemical sensors play a pivotal role in advancing therapeutic drug monitoring (TDM) and personalized therapy. However, the insufficient selectivity of electrochemical sensors based on Cytochromes P450 poses a great need for innovative machine learning (ML) integrated with cyclic voltammograms (CV) obtained from electrochemical sensors and cyclic voltammetry to construct a fully-automated system for accomplishing the precise identification and quantification of multiple drugs in the patients' blood. An effective ML-based method is proposed in this paper with the adaptive transformation of Gaussian Mixture Model (GMM) algorithm for Gaussian feature extraction from the redox peak with peculiar characterisation and a novel Artificial Neural Network (ANN)-based model IdentQuantNet for the drug identification and quantification. The simulated dataset and measured dataset of Cyclophosphamide (CP) and Ifosfamide (IFO), proposed here as model drugs, are demonstrated to validate the efficacy of our proposed method. Our method can achieve the precision at 100 % for identification task and the Mean Absolute Error (MAE) at 4.88 and 6.67 for CP and IFO for the quantification task on the measured dataset.


  • A Wearable Real-Time System for Simultaneous Wireless Power and Data Transmission to Cortical Visual Prosthesis

    by Gian Luca Barbruni, Francesca Rodino, Paolo Motto Ros, Danilo Demarchi, Diego Ghezzi, Sandro Carrara

    Wireless, miniaturised and distributed neural interfaces are emerging neurotechnologies. Although extensive research efforts contribute to their technological advancement, the need for real-time systems enabling simultaneous wireless information and power transfer toward distributed neural implants remains crucial. Here we present a complete wearable system including a software for real-time image capturing, processing and digital data transfer; an hardware for high radiofrequency generation and modulation via amplitude shift keying; and a 3-coil inductive link adapt to operate with multiple miniaturised receivers. The system operates in real-time with a maximum frame rate of 20 Hz, reconstructing each frame with a matrix of 32 × 32 pixels. The device generates a carrier frequency of 433.92 MHz. It transmits the highest power of 32 dBm with a data rate of 6 Mbps and a variable modulation index as low as 8 $\%$ , thus potentially enabling wireless communication with 1024 miniaturised and distributed intracortical microstimulators. The system is primarily conceived as an external wearable device for distributed cortical visual prosthesis covering a visual field of 20 $^{\circ }$ . At the same time, it is modular and versatile, being suitable for multiple applications requiring simultaneous wireless information and power transfer to large-scale neural interfaces.


  • Enhancing Water Safety in Decentralized Water Reuse Systems With Low-Cost Prussian Blue Amperometric Sensors for Free Chlorine Monitoring

    by Gaétan Herold, Francesca Rodino, Ata Golparvar, Eva Reynaert, Sandro Carrara

    The challenge of providing sustainable and safe water services in regions lacking centralized water infrastructure can be addressed through the utilization of on-site treatment and reuse of wastewater. However, the widespread implementation of decentralized water reuse systems is currently hindered by the considerable expenses associated with remote water quality monitoring. Specifically, when using chlorination for treatment, the fabrication and maintenance costs of free chlorine sensors pose significant drawbacks to their implementation. In this study, we present an alternative solution by mitigating the sensor cost through the utilization of electrochemical sensing coupled with a cleanroom-free sensor fabrication process. We meticulously optimized the electrodeposition process to enhance sensor stability and ensure reproducibility, achieved through precise control of reactant concentrations. Our findings demonstrate the feasibility of obtaining consistent measurements in treated greywater by employing controlled Prussian Blue electrodeposition on readily available screen-printed electrodes, resulting in variation as low as 7.44% (n = 6). Furthermore, cyclic voltammetry experiments reveal a distinct peak at -0.11 V, indicating the presence of free chlorine in treated greywater samples. This characteristic is leveraged in chronoamperometric sensing, enabling robust chemical detection with a wide dynamic linearity range (R 2 = 0.9933) spanning from 0.06 to 6.28 ppm of free chlorine in treated greywater samples and a competitive sensitivity reaching 7.6 μA/cm 2 per ppm.


  • Simultaneous and Selective Detection of Etoposide and Methotrexate With Single Electrochemical Sensors for Therapeutic Drug Monitoring

    by Francesca Rodino, Mattia Bartoli, Sandro Carrara

    Etoposide and methotrexate are widely used chemotherapy drugs in cancer treatment, targeting specific cellular processes crucial for DNA replication and cell division. Despite their efficacy, both drugs have significant adverse toxic effects due to the narrow therapeutic window, which can result in either over-exposure or insufficient exposure. Therefore, providing therapeutic drug monitoring is crucial to optimize pharmacotherapy outcomes to provide optimal dosage adjustment, and minimize adverse effects with personalized medicine and therapy. Conventional cytotoxic chemotherapies involve the combination of multiple antineoplastic drugs. Therefore, when developing sensors for therapeutic drug monitoring, it is important to account for the potential interactions between different drugs when they are simultaneously present in the blood of patients. However, the electrochemical interaction between etoposide and methotrexate has not been studied in multiplexed concentration monitoring. Therefore, our study aims to investigate their oxidation mechanism during simultaneous detection on the same sensor. We actually succeeded in demonstrating the simultaneous detections of the two drugs but, also, their mutual interference due to their oxidative cross-reactivity. To that aim, the reaction mechanisms between etoposide and methotrexate during their interaction on our sensor are presented in detail in this paper. A deep understanding of such an interaction is clearly crucial to calibrate the sensor in order to provide accurate and reliable detection of the two anti-cancer compounds.