BPBahattin Paslı

Bahattin Paslı

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Bahattin Paslı has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Top Cited Papers

    Reference Hallucination, Citation Reliability, and Readability of Large Language Models in Anatomy‐Related Question Answering

    by Mehmet Ülkir, Bahattin Paslı

    Large language models (LLMs) are increasingly used in medical education and academic writing. However, concerns remain regarding reference hallucination, citation, and the reliability of LLM‐generated content. This study aimed to evaluate the performance of ChatGPT 5.2, Gemini 3 Pro, and DeepSeek V3.2 in generating anatomy‐related responses by assessing bibliographic reference accuracy, citation content consistency, and the readability of LLM‐generated content. A total of 120 open‐ended anatomy questions covering six anatomical categories (neuroanatomy, musculoskeletal, respiratory and circulatory, gastrointestinal, urogenital and endocrine, head and neck) were submitted to each model. Individual citation components, including author names, article titles, journal names, publication details, and PMIDs, were verified against indexed sources. Citation content consistency was evaluated using a three‐point Likert scale. Readability was assessed using the Flesch Reading Ease score, Flesch–Kincaid Grade Level, Coleman–Liau, and Simple Measure of Gobbledygook indices. A total of 1800 references were analyzed. ChatGPT 5.2 demonstrated the lowest hallucination rate (23.2%), whereas Gemini 3 Pro and DeepSeek V3.2 exhibited substantially higher hallucination rates (45.8% and 47.5%, respectively). DeepSeek V3.2 achieved the highest accuracy for several individual bibliographic components, including author names, article titles, volumes, issues, pages, and journal names. PMID accuracy remained limited across all models, ranging from 25.1% to 57.6%. Citation content consistency differed significantly among the models ( p < 0.001), with ChatGPT 5.2 demonstrating the highest proportion of fully supported citations (67.2%), compared with Gemini 3 Pro (42.5%) and DeepSeek V3.2 (41.0%). Citation accuracy differed significantly across most anatomical subcategories, with the greatest intermodel discrepancy observed in head and neck anatomy. Readability analyses indicated that the generated responses generally required college‐level reading proficiency. Although LLMs can generate plausible anatomy‐related responses, substantial limitations remain regarding reference accuracy, hallucination, and citation reliability. Human verification remains essential before incorporating LLM‐generated references into academic or educational materials.


  • The middle hepatic artery: prevalence and origin patterns of a distinct segment 4 artery

    by Tuğçe Taşkındere Abbasoğlu, Akın Abbasoğlu, Bahattin Paslı, Helin Yücedağ Gündoğdu, Mehmet Ülkir, Muşturay Karçaaltıncaba, Ayşegül Fırat

    Background The middle hepatic artery (MHA) is commonly used to describe the artery supplying segment 4 of the liver. Because preservation of segment 4 inflow is important in hepatobiliary surgery, especially in living donor liver transplantation and split liver transplantation, recognition of its presence and origin is clinically relevant. This study aimed to evaluate the prevalence and origin patterns of the MHA. Methods A total of 706 abdominal computed tomography angiography examinations were retrospectively reviewed. In this study, the MHA was defined as a separately identifiable arterial branch supplying segment 4 at or near the hepatic hilum. Its presence, origin, and distribution according to the hepatic arterial anatomy observed among MHA-positive cases were recorded. Results The MHA was identified in 430 of 706 cases (60.9%). Among these, the most common origin was the left hepatic artery (54.2%), followed by the right hepatic artery (30.7%). Less frequent origins included the proper hepatic artery (11.2%), replaced left hepatic artery (2.1%), gastroduodenal artery (0.7%), replaced right hepatic artery (0.7%), common hepatic artery (0.2%), and accessory left hepatic artery (0.2%). In cases with a replaced right hepatic artery, the MHA most frequently originated from the left hepatic artery, whereas in cases with a replaced left hepatic artery, it most frequently arose from the right hepatic artery. Conclusion The MHA was present in approximately three-fifths of cases and showed considerable variability in its origin. When no MHA was separately visualized, this should not be interpreted as absence of arterial perfusion to segment 4, which may also be supplied by intrahepatic or multiple small branches not delineated as a single artery. Recognition of these patterns may improve preoperative vascular assessment in hepatobiliary and transplant surgery.

  • Open Access

    Anatomical Variability of the Proximal Femur: A Morphometric Study Relevant to Orthopedic Implant Design

    by Bahattin Pasli, Mehmet Ulkir, Barış KAFA

    Proximal femur morphometry plays a crucial role in fracture management and hip arthroplasty by affecting implant fit, biomechanics, and surgical outcomes. Therefore, the utilization of anatomical data reflecting inter-individual variability is essential for optimizing implant design and minimizing implant-bone mismatch. This study aimed to evaluate proximal femoral morphometry and provide data relevant to implant design. A total of 73 unpaired dry femurs of unknown age and sex (43 right, 30 left) were analyzed. Measurements included femoral length, neck-body angle, and femoral head and neck dimensions. All measurements were independently performed by two anatomists and repeated using a tape measure, a digital caliper, and a protractor. Interobserver and intra observer reliabilities were assessed using intraclass correlation coefficients (ICC). Statistical analyses were performed, including descriptive statistics, pairwise comparisons, and correlation analyses. Measurement reliability ranged from good to excellent (ICC: 0.749-0.999). Mean femoral length was 43.7±3.0 cm, and mean neck-body angle was 126.0°±4.6°. No significant side differences were observed for femoral length, femoral head, or femoral neck dimensions; however, the neck-body angle differed significantly (p<0.001). The correlation analysis revealed positive associations among parameters of the femoral head and neck. Femoral length showed strong correlations with head dimensions, whereas the neck-body angle demonstrated no significant correlations with other parameters. The lack of age and sex data should be considered when interpreting these findings. The proximal femur exhibits substantial morphometric variability. These findings provide preliminary data that may contribute to the existing literature and help inform the design of future implants and prostheses.

  • Open Access

    Thin cortical translucent area of the iliac wing: morphometric analysis and implications for surgical safety

    by Helin Yücedağ Gündoğdu, Bahattin Paslı, Burcu Erçakmak Güneş

    The iliac wing is a frequently used fixation site in the surgical management of pelvic and acetabular fractures. Achieving safe implant placement in this region necessitates a comprehensive understanding of local morphology. However, the morphometric characteristics and surgical safety margins of the thin cortical translucent area (PLA) located in the central iliac wing have not been sufficiently defined. This may pose a significant challenge in evaluating the risk of cortical perforation, particularly during implant placement. This study aimed to evaluate the morphometric characteristics of the PLA and its relationship to fixation corridors. Fifty-one unpaired dry hip bones were examined. The thin cortical translucent region was identified using photoluminescence. Photograph-based measurements were conducted utilising ImageJ software on standardised photographs. Dimensions, area, distances to reference landmarks and relationships with the iliac pillar and supraacetabular corridors were assessed. The safe angular deviation range for anterior inferior iliac spine (AIIS)-origin screw fixation was calculated. Cortical thickness was measured using a digital thickness gauge. The vertical and horizontal diameters and area of the PLA were 56.24 ± 16.56 mm, 59.92 ± 24.83 mm and 28.10 ± 16.47 cm2, respectively. Mean distances to the anterior superior iliac spine, posterior superior iliac spine, iliac crest and acetabular roof were 62.12 ± 19.84 mm, 71.03 ± 12.17 mm, 19.88 ± 11.61 mm and 56.02 ± 9.09 mm, respectively. The safe angular deviation for AIIS-origin screw fixation was 16.94° ± 4.43°. The central cortical thickness was 2.07 ± 1.60 mm (range 0.3-5.9). The PLA is a clinically important region characterised by marked central cortical thinning and individual variability. Individualised morphometric assessment and preoperative imaging may help define safer zones for fixation planning and donor-site procedures. Level V.

  • Open Access

    Navicular bone morphometry for implant planning in fracture surgery: a dry bone analysis

    by Helin Yücedağ Gündoğdu, Bahattin Paslı

    Objective: The purpose of this study is to quantitatively characterise surgically relevant morphometric features of dry navicular bones and to provide anatomical reference values that can be utilised in implant placement. Methods: Fifty-five isolated, unpaired dry navicular bones without macroscopic deformity were examined. Tuberosity morphology, tuberosity–medial cuneiform distances, navicular body dimensions (mediolateral width, level-specific anteroposterior measurements, and depth), talonavicular articular surface depth, and concavity index were evaluated using a digital caliper and digital thickness gauge. Results: The narrowest tuberosity width, anteroposterior length, and supero-inferior height were 6.59 ± 1.28 mm, 16.38 ± 2.43 mm, and 11.24 ± 1.26 mm, respectively. The tuberosity groove depth was 2.05 ± 0.92 mm. The distances from the tuberosity midpoint to the medial cuneiform articular surface at the nearest and farthest points were 21.86 ± 3.11 mm, 29.65 ± 3.37 mm. The mean mediolateral body width was 37.69 ± 3.54 mm. Level-specific anteroposterior dimensions were 18.01 ± 2.34 mm, 15.15 ± 2.15 mm, and 12.56 ± 1.62 mm, whereas the corresponding body depths were 18.35 ± 3.01 mm, 25.24 ± 2.30 mm, and 22.52 ± 2.47 mm, respectively. Conclusion: These findings provide surgically relevant anatomical reference values that may assist preoperative planning and support safer fixation of navicular fractures, and contribute to the design and optimisation of navicular implants and fixation devices.

  • Open Access

    Is artificial intelligence getting better at anatomy? A two‐year review of ChatGPT 's free public versions

    by Bahattin Paslı, Ceren Günenç Beşer

    Artificial intelligence and large language models have significantly influenced medical education by enhancing learning experiences. While previous studies have assessed ChatGPT's performance on anatomy‐related questions, a notable gap remains in understanding its accuracy over time. This longitudinal study evaluated the progression of ChatGPT's accuracy using 120 five‐option multiple‐choice questions covering anatomical systems, written by anatomy faculty members. Incorrect responses were categorized as informational, logical, or combined errors, while correct responses were genuine or guessed (selecting the correct option despite providing incorrect explanatory content). Performance was further evaluated in relation to the characteristics of questions and their cognitive levels according to Bloom's Taxonomy. Following a deliberate interval of approximately 2 years, the same set was administered to ChatGPT‐3.5, ChatGPT‐4o, and ChatGPT‐5 without providing feedback. Temporal differences in accuracy and reasoning were analyzed using Cochran's Q test. Correct‐response rates increased significantly across versions, from 45.8% (ChatGPT‐3.5) to 73.3% (ChatGPT‐4o) and 86.7% (ChatGPT‐5) ( Q = 55.433, p < 0.001), accompanied by reductions in combined errors and guessed correct. Informational errors remained predominant, accounting for 47/65 (72.3%), 26/32 (81.25%), and 12/16 (75.0%) of incorrect responses in ChatGPT‐3.5, ChatGPT‐4o, and ChatGPT‐5, respectively. Performance improved significantly across successive versions at both lower and higher cognitive levels ( Q = 40.478, p < 0.001; Q = 16.095, p < 0.001, respectively). The 2‐year evolution of ChatGPT's anatomical knowledge highlights its potential as a supplementary resource for anatomy education and individualized learning. This study provides modest evidence of progressive improvements in anatomical accuracy and reasoning across successive model versions, suggesting that continued refinement may further enhance reliability.


  • Hepatic arterial variants on CT angiography: applicability and coverage of the CRL classification system

    by Tuğçe Taşkındere Abbasoğlu, Bahattin Paslı, Helin Yücedağ Gündoğdu, Muşturay Karçaaltıncaba, Ayşegül Fırat


  • Open Access

    Temporal Trends and Demographic Characteristics in Body Donation Applications: A Single University Experience

    by Bahattin Paslı, Mehmet Ülkir, Helin Yücedağ Gündoğdu, Mehmet Deniz Demiryürek

    Objective: Body donation remains essential for anatomy education and surgical skills training. Despite advances in simulation and virtual/augmented/mixed reality, donated human bodies provide unmatched tissue realism and anatomical variation. However, many institutions still face cadaver shortages. Understanding temporal fluctuations in donation applications and their demographic correlations may inform targeted outreach and support the sustainability of body donation programs. This study aims to evaluate the effectiveness and outcome of ongoing National Body Donation Programs at our institution. Methods: Retrospective body donation forms submitted to Hacettepe University between 1990 and 2025 were reviewed, including both completed donations and registered applicants. Demographic variables, including application year and sex, were analyzed alongside temporal trends. Results: Between 2003 and 2025, a total of 267 body donation applications were submitted, of which 20 donors were accepted by our institution. The annual number of applications ranged from 0 to 29. A modest upward trend in the annual number of applications was observed beginning in 2012, the year in which the National Body Donation Program was initiated (β = 1.48, p = 0.052). The applicant population comprised 61.8% males and 38.2% females, with female applicants submitting their applications at a significantly younger age than males (p = 0.046). Applicants aged ≤ 30 years represented 13.5% of the population, while those aged ≥ 65 years comprised 31.5%. Conclusion: These findings provide valuable mid-term institutional data that may inform the planning and sustainability of body donation programs in medical education. Continuous monitoring of program outcomes is essential, enabling a proactive management approach and the development of strategies to enhance program effectiveness.

  • Anatomy In The Official Records Of The Ottoman Empire: A Thematic Analysis Of State Archives

    by Helin Yücedağ Gündoğdu, Bahattin Paslı

    Objective: Although Ottoman medical education has been extensively studied using archival sources, the online catalogue of the Ottoman State Archives has not been systematically searched for records relating to anatomy education and cadaver procurement. This study analyzes online catalogue summaries to examine the bureaucratic, educational, spatial, and legal dimensions of these subjects as represented in the catalogue. Material and Methods: The online catalogue of the Presidency of the Republic of Türkiye Directorate of State Archives was systematically searched using the keywords teşrih (dissection/anatomy) and anatomi (anatomy). After removing duplicates and applying the predefined exclusion criteria, the summaries of the eligible catalogue records were analyzed using an inductive, semantic approach to thematic analysis informed by Braun and Clarke’s six-phase framework. The catalogue summaries were reviewed and coded collaboratively by two researchers, and the final thematic classification of all 142 records was reached by consensus. Results: The keyword searches identified 262 online catalogue records, of which 142 were included in the thematic analysis after 120 records were excluded. Four themes emerged: instructional personnel (54.9%), instructional materials (29.6%), cadaver procurement and legal–religious issues (8.5%), and dissection facilities (7.0%). Although personnel administration was the largest theme, other catalogue summaries described plans to locate dissection facilities near cemeteries of different religious communities, the importation of anatomical teaching models, the translation of anatomical textbooks, and cadaver procurement for anatomy education. Conclusion: This study provides a catalogue-based overview of anatomy education and cadaver procurement in the Ottoman Empire, highlighting the central role of state administration in shaping anatomical education and enriching the historiography of Ottoman medical modernization.