QLQingyu Liu

Qingyu Liu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Qingyu Liu has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Cervical collar use following anterior cervical hybrid surgery: protocol for a prospective randomized, time-controlled trial

    by Junbo He, Qingyu Liu, Zijiao Yang, Hao Liu, Tingkui Wu, Chen Ding, Kangkang Huang, Beiyu Wang

    Introduction: Cervical hybrid surgery (HS) combines anterior cervical discectomy and fusion (ACDF) and cervical disc arthroplasty (CDA) to establish an individualized surgical plan for patients with multiple cervical disc degenerative diseases. In order to maintain the stability of the spine after HS, an external cervical collar is often used. However, there is still controversy regarding the importance of a cervical collar following surgery. This study aims to determine whether the cervical collar is effective and how long it should be worn after surgery. Methods: This is a randomized, single-center, prospective, parallel-controlled trial. Eligible participants will be selected according to the inclusion and exclusion criteria. The primary outcome is the neck disability index, which will be evaluated before surgery and at one week, 3 weeks, 6 weeks, 3 months, 6 months, and 12 months following surgery. The secondary outcomes consist of the Japanese Orthopedic Association Scores, MOS 36-item short-form health survey (SF-36), visual analog scale, Pittsburgh Sleep Quality Index (PSQI), Bazaz dysphagia scoring system, Falls Efficacy Scale, cervical collar satisfaction score, neck soft tissue assessment, and Braden Scale, as well as radiologic assessments for cervical lordosis, disc height of the operative levels, fusion rate, range of motion (ROM), and complications including anterior bone loss, prosthesis migration, and heterotopic ossification. The clinical and radiologic examinations were performed by investigators with no therapeutic relationship with the individual patient. All radiographs were examined by one independent radiologist. Ethics and dissemination: The results of this study will be published in peer-reviewed journals and presented at conferences. Upon completion of this trial, our findings could provide an appropriate cervical collar-wearing guideline for patients receiving HS. Trial registration: ChiCTR.org.cn ChiCTR2000033002. Registered on 2020–05-17.


  • Open Access

    SurgSmart: an artificial intelligent system for quality control in laparoscopic cholecystectomy: an observational study

    by Shangdi Mm Wu, Zixin Chen, Runwen Mm Liu, Ang Li, Yu Cao, Ailin Wei, Qingyu Liu, Jie Bs Liu, Yuxian Bs Wang, Jingwen Jiang, et al.

    Background: The rate of bile duct injury (BDI) in laparoscopic cholecystectomy (LC) continues to be high due to low critical view of safety (CVS) achievement and the absence of an effective quality control system. The development of an intelligent system enables the automatic quality control of LC surgery and, eventually, the mitigation of BDI. This study aims to develop an intelligent surgical quality control system for LC and using the system to evaluate LC videos and investigate factors associated with CVS achievement. Materials and Methods: SurgSmart, an intelligent system capable of recognizing surgical phases, disease severity, critical division action, and CVS automatically, was developed using training datasets. SurgSmart was also applied in another multicenter dataset to validate its application and investigate factors associated with CVS achievement. Results: SurgSmart performed well in all models, with the critical division action model achieving the highest overall accuracy (98.49%), followed by the disease severity model (95.45%) and surgical phases model (88.61%). CVS I, CVS II, and CVS III had an accuracy of 80.64%, 97.62%, and 78.87%, respectively. CVS was achieved in 4.33% in the system application dataset. Additionally, the analysis indicated that surgeons at a higher hospital-level had a higher CVS achievement rate. However, there was still considerable variation in CVS achievement among surgeons in the same hospital. Conclusion: SurgSmart, the surgical quality control system, performed admirably in our study. Additionally, the system’s initial application demonstrated its broad potential for use in surgical quality control. Export