Abdullah Mohammad Tanvirul Hoque
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Abdullah Mohammad Tanvirul Hoque has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Ahasan Habib
Department of Electrical & Electronic Engineering, Rajshahi University of Engineering and Technology, Rajshahi P.O. Box 6204, Bangladesh
1 shared publication Asad Arshad
College of Chemicals and Materials, King Fahd University of Petroleum & Minerals, Dhahran, Saudi Arabia
1 shared publication- Asad Muhammad Butt
College of Chemicals and Materials, King Fahd University of Petroleum and Minerals, Dhahran, Saudi Arabia
1 shared publication Eakub Ali
Department of Electrical and Electronic Engineering, Bangabandhu Sheikh Mujibur Rahman Science and Technology University, Gopalganj, Bangladesh
1 shared publication- Julfikar Haider
Department of Engineering Manchester Metropolitan University Manchester UK
1 shared publication - Khurram Karim Qureshi
King Fahd University of Petroleum and Minerals
1 shared publication
Latest Publications
- Open Access
- 1 January 2024
- Published by Wiley in Journal of Sensors
- Vol. 2024 (1)
Titanium‐Coated Extremely Sensitive SPR Biosensor for Cancer Cell Detection
In this study, a D‐shaped, extremely sensitive surface plasmon resonance (SPR) sensor with a blue shift characteristic is proposed that can be used to identify various malignant cancer cells. A sensing layer made of titanium is inserted to produce intense sensitivity. For the simulation and numerical evaluation of the proposed biosensor, we used the finite element method (FEM) and the COMSOL Multiphysics 5.6 software. To regulate how much light passes through the sensor, which incites the released electrons at the surface of the plasmonic material, air holes in different radii are used. The characteristics that make our proposed sensor superior to other D‐shaped SPR sensors are—it gives an excellent amplitude sensitivity (AS) of 200 RIU−1 also ensures extremely high wavelength sensitivity (WS) spanning from 34,350 to 42,145 nm/RIU with an outstanding spectral resolution of 2.37 × 10−6 RIU. Furthermore, the R2 (0.9966) value is also extremely close to 1 which ensures the quality of our sensor regarding its performance. The given sensor is tailored for four vital human cancers, which are blood cancer, skin cancer, cervical cancer, and adrenal gland cancer. Here, optimization of the structural geometric parameters, plasmonic materials, and material thickness are also conducted in search of the best functionality of the sensor. The offered structure, nonetheless, can be an obvious prologue in the case of the crucial human cancer detection platform due to its mild sensing performances.
- 1 January 2024
- Published by Wiley in Journal of Sensors
- Vol. 2024 (1)
Open AccessTitanium‐Coated Extremely Sensitive SPR Biosensor for Cancer Cell Detection
In this study, a D‐shaped, extremely sensitive surface plasmon resonance (SPR) sensor with a blue shift characteristic is proposed that can be used to identify various malignant cancer cells. A sensing layer made of titanium is inserted to produce intense sensitivity. For the simulation and numerical evaluation of the proposed biosensor, we used the finite element method (FEM) and the COMSOL Multiphysics 5.6 software. To regulate how much light passes through the sensor, which incites the released electrons at the surface of the plasmonic material, air holes in different radii are used. The characteristics that make our proposed sensor superior to other D‐shaped SPR sensors are—it gives an excellent amplitude sensitivity (AS) of 200 RIU−1 also ensures extremely high wavelength sensitivity (WS) spanning from 34,350 to 42,145 nm/RIU with an outstanding spectral resolution of 2.37 × 10−6 RIU. Furthermore, the R2 (0.9966) value is also extremely close to 1 which ensures the quality of our sensor regarding its performance. The given sensor is tailored for four vital human cancers, which are blood cancer, skin cancer, cervical cancer, and adrenal gland cancer. Here, optimization of the structural geometric parameters, plasmonic materials, and material thickness are also conducted in search of the best functionality of the sensor. The offered structure, nonetheless, can be an obvious prologue in the case of the crucial human cancer detection platform due to its mild sensing performances.
- Open Access
- 24 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 74486-74499
U-Grooved Selectively Coated and Highly Sensitive PCF-SPR Sensor for Broad Range Analyte RI Detection
Point-of-care (POC) diagnostic medical devices require simple but sensitive and inclusive detection capabilities. This study develops a unique photonic crystal fiber-based surface plasmon resonance (PCF-SPR) sensor that uses a u-grooved selective coating for extremely sensitive remote and biosensing applications. Scale-down (SCD) air holes control the path that incoming light takes through the sensor in order to activate the free electrons that are present there. To reduce outward radiation, perfectly matched layers (PML) of the absorbing boundary are integrated in addition to optimizing the structural geometry and material thickness. The Finite Element Method (FEM) is employed to quantitatively tune the properties of light directing and sensitivity of the proposed sensor. The proposed sensor has the maximum amplitude sensitivity (AS) of 1189 RIU -1 , the highest wavelength sensitivity (WS) of 12,500 nm/(RIU), and an outstanding resolution of 8.0×10 -6 RIU. The constructed model covers a large refractive index (RI) range of unknown samples, ranging from 1.29 to 1.40. This range allows this sensor to cover the detection of a wide range of bio-analytics, including viruses, cancer cells, carbohydrates, proteins, and DNA/RNA etc. We strongly believe that the suggested sensor will play an extremely useful role in the detection of POC bio-sample detection.
- 24 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 74486-74499
Open AccessU-Grooved Selectively Coated and Highly Sensitive PCF-SPR Sensor for Broad Range Analyte RI Detection
Point-of-care (POC) diagnostic medical devices require simple but sensitive and inclusive detection capabilities. This study develops a unique photonic crystal fiber-based surface plasmon resonance (PCF-SPR) sensor that uses a u-grooved selective coating for extremely sensitive remote and biosensing applications. Scale-down (SCD) air holes control the path that incoming light takes through the sensor in order to activate the free electrons that are present there. To reduce outward radiation, perfectly matched layers (PML) of the absorbing boundary are integrated in addition to optimizing the structural geometry and material thickness. The Finite Element Method (FEM) is employed to quantitatively tune the properties of light directing and sensitivity of the proposed sensor. The proposed sensor has the maximum amplitude sensitivity (AS) of 1189 RIU -1 , the highest wavelength sensitivity (WS) of 12,500 nm/(RIU), and an outstanding resolution of 8.0×10 -6 RIU. The constructed model covers a large refractive index (RI) range of unknown samples, ranging from 1.29 to 1.40. This range allows this sensor to cover the detection of a wide range of bio-analytics, including viruses, cancer cells, carbohydrates, proteins, and DNA/RNA etc. We strongly believe that the suggested sensor will play an extremely useful role in the detection of POC bio-sample detection.