Jian Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jian Wu has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Dongyun Sun
Eye Institute, Affiliated Hospital of Nantong University, Nantong, China
1 shared publication - Huaijin Guan
Department of Ophthalmology, Affiliated Hospital of Nantong University, 20 Xisi Road, Nantong, Jiangsu, China.
1 shared publication - Huaijin Guan
Eye Institute, Affiliated Hospital of Nantong University, Nantong, Jiangsu, China; Nantong University, Nantong, Jiangsu, China
1 shared publication - Huaijin Guan
Eye Institute, Affiliated Hospital of Nantong University, Nantong, China
1 shared publication - Lihua Kang
Department of Ophthalmology, Affiliated Hospital of Nantong University, Nantong, Jiangsu 226001, China
1 shared publication - Min Ji
Eye Institute, Affiliated Hospital of Nantong University, Nantong, China
1 shared publication
Latest Publications
- Open Access
- 31 July 2026
- Published by Wolters Kluwer Health in Medicine
- Vol. 105 (31) , e49632
Effect of temperature variation on the corneal endothelial cell during femtosecond laser-assisted cataract surgery compared with conventional phacoemulsification cataract surgery: A prospective study
To evaluate whether the corneal endothelium experiences increased temperatures and thermal damage during femtosecond laser-assisted cataract surgery (FLACS), we performed comparative in vivo studies. These studies compared FLACS with conventional phacoemulsification cataract surgery (CPS) systems. In this study, 410 eyes with grade II or III nuclear sclerotic cataracts undergoing either CPS (n = 213) or FLACS (n = 197) were examined. All eyes received balanced salt solution at 21°C or 29°C during phacoemulsification. In FLACS, a SoftFit patient interface (PI) was used at 21°C or 29°C. The surface temperature and intraocular temperature were recorded using a thermometer. Postoperative therapies were identical across all groups. Endothelial cell loss (ECL) was measured with a specular microscope before and 1 week post-surgery. The average temperature in the anterior chamber was similar after FLACS and CPS. FLACS used less cumulative dissipated energy (CDE) and resulted in lower ECL than CPS. However, no significant difference was found in mean CDE or ECL between subcohorts with different PI temperatures. The same applied to subcohorts with different balanced salt solution temperatures. At a PI temperature of 21°C, both anterior chamber temperature and ECL were lower in the first 10 minutes after femtosecond laser (FL) treatment than afterward. FL does not cause temperature increases in the anterior chamber. In contrast, FLACS reduces CDE and ECL compared with CPS. Additionally, lowering PI temperature and performing FL before phacoemulsification – especially during the first 10 minutes – may help protect the corneal endothelium.
- 31 July 2026
- Published by Wolters Kluwer Health in Medicine
- Vol. 105 (31) , e49632
Open AccessEffect of temperature variation on the corneal endothelial cell during femtosecond laser-assisted cataract surgery compared with conventional phacoemulsification cataract surgery: A prospective study
To evaluate whether the corneal endothelium experiences increased temperatures and thermal damage during femtosecond laser-assisted cataract surgery (FLACS), we performed comparative in vivo studies. These studies compared FLACS with conventional phacoemulsification cataract surgery (CPS) systems. In this study, 410 eyes with grade II or III nuclear sclerotic cataracts undergoing either CPS (n = 213) or FLACS (n = 197) were examined. All eyes received balanced salt solution at 21°C or 29°C during phacoemulsification. In FLACS, a SoftFit patient interface (PI) was used at 21°C or 29°C. The surface temperature and intraocular temperature were recorded using a thermometer. Postoperative therapies were identical across all groups. Endothelial cell loss (ECL) was measured with a specular microscope before and 1 week post-surgery. The average temperature in the anterior chamber was similar after FLACS and CPS. FLACS used less cumulative dissipated energy (CDE) and resulted in lower ECL than CPS. However, no significant difference was found in mean CDE or ECL between subcohorts with different PI temperatures. The same applied to subcohorts with different balanced salt solution temperatures. At a PI temperature of 21°C, both anterior chamber temperature and ECL were lower in the first 10 minutes after femtosecond laser (FL) treatment than afterward. FL does not cause temperature increases in the anterior chamber. In contrast, FLACS reduces CDE and ECL compared with CPS. Additionally, lowering PI temperature and performing FL before phacoemulsification – especially during the first 10 minutes – may help protect the corneal endothelium.
- Open Access
- 18 June 2019
- Published by Press of International Journal of Ophthalmology (IJO Press) in International Journal of Ophthalmology
- Vol. 12 (6) , 1047-1049
Incomplete capsulotomy and lens fragmentation during femtosecond laser-assisted cataract surgery associated with emulsified anterior chamber silicone oil: a case report
- 18 June 2019
- Published by Press of International Journal of Ophthalmology (IJO Press) in International Journal of Ophthalmology
- Vol. 12 (6) , 1047-1049
Open AccessIncomplete capsulotomy and lens fragmentation during femtosecond laser-assisted cataract surgery associated with emulsified anterior chamber silicone oil: a case report
- Open Access
- 1 January 2018
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. 12, 1815-1822
Comparison of variations in cornea after one-handed and two-handed coaxial phacoemulsification
Purpose: To compare corneal variations in patients undergoing one-handed and two-handed coaxial phacoemulsification. Setting: Eye Institute, Affiliated Hospital of Nantong University, Nantong, China. Design: Prospective consecutive nonrandomized comparative cohort study. Methods: Patients with cataracts were subject to one-handed (one-handed group) or two-handed coaxial phacoemulsification (two-handed group). Intraoperative phaco parameters and postoperative outcomes, such as visual acuity, surgically induced astigmatism (SIA), corneal volume, central corneal thickness, and corneal endothelial cell counts/size were compared. Results: No significant differences in the intraoperative phaco parameters were noted between the 2 groups. At postoperative week 1, visual outcomes were significantly improved in the one-handed compared with the two-handed group (all P<0.05). Corneal volume, central corneal thickness, and average cell size were significantly decreased in the one-handed group compared with two-handed group (all P<0.05), but the aforementioned differences were ameliorated at 1 month and 3 months postoperatively. Endothelial cell loss was significantly decreased in the one-handed group compared with the two-handed group at any follow-up point (all P<0.05). No significant differences in SIA on the anterior surface were noted between the 2 groups. SIA on the posterior surface was significantly decreased in the one-handed group compared with the two-handed group at 1 week postoperatively (P=0.043) but not at 1 month and 3 months postoperatively. Conclusion: One-handed phacoemulsification has the advantages of less trauma to the cornea and better early visual outcomes compared with the two-handed technique.
- 1 January 2018
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. 12, 1815-1822
Open AccessComparison of variations in cornea after one-handed and two-handed coaxial phacoemulsification
Purpose: To compare corneal variations in patients undergoing one-handed and two-handed coaxial phacoemulsification. Setting: Eye Institute, Affiliated Hospital of Nantong University, Nantong, China. Design: Prospective consecutive nonrandomized comparative cohort study. Methods: Patients with cataracts were subject to one-handed (one-handed group) or two-handed coaxial phacoemulsification (two-handed group). Intraoperative phaco parameters and postoperative outcomes, such as visual acuity, surgically induced astigmatism (SIA), corneal volume, central corneal thickness, and corneal endothelial cell counts/size were compared. Results: No significant differences in the intraoperative phaco parameters were noted between the 2 groups. At postoperative week 1, visual outcomes were significantly improved in the one-handed compared with the two-handed group (all P<0.05). Corneal volume, central corneal thickness, and average cell size were significantly decreased in the one-handed group compared with two-handed group (all P<0.05), but the aforementioned differences were ameliorated at 1 month and 3 months postoperatively. Endothelial cell loss was significantly decreased in the one-handed group compared with the two-handed group at any follow-up point (all P<0.05). No significant differences in SIA on the anterior surface were noted between the 2 groups. SIA on the posterior surface was significantly decreased in the one-handed group compared with the two-handed group at 1 week postoperatively (P=0.043) but not at 1 month and 3 months postoperatively. Conclusion: One-handed phacoemulsification has the advantages of less trauma to the cornea and better early visual outcomes compared with the two-handed technique.