Feng Rong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Feng Rong has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Degang Xu
School of Precision Instruments and Optoelectronics Engineering, Tianjin University, Tianjin, China
2 shared publications - Jia Shi
Tianjin Key Laboratory of Optoelectronic Detection Technology and System, School of Electronic and Information Engineering, Tiangong University, Tianjin, China
2 shared publications - Jianquan Yao
Tianjin University
2 shared publications - Junfa Zhao
Tianjin Key Laboratory of Optoelectronic Detection Technology and Systems, Tianjin Polytechnic University, Tianjin 300387, China
2 shared publications - Wei Xu
Tianjin Key Laboratory of Optoelectronic Detection Technology and System, School of Electronics and Information Engineering, Tiangong University, Tianjin 300387, P. R. China
2 shared publications - Xianchao Yang
Institute of Laser and Optoelectronics, College of Precision Instrument and Optoelectronic Engineering, Tianjin University, Tianjin 300072, China
2 shared publications
Latest Publications
- Open Access
Relative Humidity Sensor Based on No-Core Fiber Coated by Agarose-Gel Film
A relative humidity (RH) sensor based on single-mode–no-core–single-mode fiber (SNCS) structure is proposed and experimentally demonstrated. The agarose gel is coated on the no-core fiber (NCF) as the cladding, and multimode interference (MMI) occurs in the SNCS structure. The transmission spectrum of the sensor is modulated at different ambient relative humidities due to the tunable refractive index property of the agarose gel film. The relative humidity can be measured by the wavelength shift and intensity variation of the dip in the transmission spectra. The humidity response of the sensors, coated with different concentrations and coating numbers of the agarose solution, were experimentally investigated. The wavelength and intensity sensitivity is obtained as −149 pm/%RH and −0.075 dB/%RH in the range of 30% RH to 75% RH, respectively. The rise and fall time is tested to be 4.8 s and 7.1 s, respectively. The proposed sensor has a great potential in real-time RH monitoring.
Open AccessRelative Humidity Sensor Based on No-Core Fiber Coated by Agarose-Gel Film
A relative humidity (RH) sensor based on single-mode–no-core–single-mode fiber (SNCS) structure is proposed and experimentally demonstrated. The agarose gel is coated on the no-core fiber (NCF) as the cladding, and multimode interference (MMI) occurs in the SNCS structure. The transmission spectrum of the sensor is modulated at different ambient relative humidities due to the tunable refractive index property of the agarose gel film. The relative humidity can be measured by the wavelength shift and intensity variation of the dip in the transmission spectra. The humidity response of the sensors, coated with different concentrations and coating numbers of the agarose solution, were experimentally investigated. The wavelength and intensity sensitivity is obtained as −149 pm/%RH and −0.075 dB/%RH in the range of 30% RH to 75% RH, respectively. The rise and fall time is tested to be 4.8 s and 7.1 s, respectively. The proposed sensor has a great potential in real-time RH monitoring.
- Open Access
Improved Numerical Calculation of the Single-Mode-No-Core-Single-Mode Fiber Structure Using the Fields Far from Cutoff Approximation
Multimode interferometers based on the single-mode-no-core-single-mode fiber (SNCS) structure have been widely investigated as functional devices and sensors. However, the theoretical support for the sensing mechanism is still imperfect, especially for the cladding refractive index response. In this paper, a modified model of no-core fiber (NCF) based on far from cut-off approximation is proposed to investigate the spectrum characteristic and sensing mechanism of the SNCS structure. Guided-mode propagation analysis (MPA) is used to analyze the self-image effect and spectrum response to the cladding refractive index and temperature. Verified by experiments, the performance of the SNCS structure can be estimated specifically and easily by the proposed method.
Open AccessImproved Numerical Calculation of the Single-Mode-No-Core-Single-Mode Fiber Structure Using the Fields Far from Cutoff Approximation
Multimode interferometers based on the single-mode-no-core-single-mode fiber (SNCS) structure have been widely investigated as functional devices and sensors. However, the theoretical support for the sensing mechanism is still imperfect, especially for the cladding refractive index response. In this paper, a modified model of no-core fiber (NCF) based on far from cut-off approximation is proposed to investigate the spectrum characteristic and sensing mechanism of the SNCS structure. Guided-mode propagation analysis (MPA) is used to analyze the self-image effect and spectrum response to the cladding refractive index and temperature. Verified by experiments, the performance of the SNCS structure can be estimated specifically and easily by the proposed method.
- 20 September 2010
- Published by China Science Publishing & Media Ltd. in JOURNAL OF ELECTRONIC MEASUREMENT AND INSTRUMENT
- Vol. 24 (9) , 872-877
Development of ILS signal monitor
- 20 September 2010
- Published by China Science Publishing & Media Ltd. in JOURNAL OF ELECTRONIC MEASUREMENT AND INSTRUMENT
- Vol. 24 (9) , 872-877
Development of ILS signal monitor