Kc Richards
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Kc Richards has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
B Martin
1 shared publicationB Todd
1 shared publicationDA Folwick
1 shared publicationHj Kitzman
1 shared publicationJ Wiedrich
1 shared publicationK Whitford
1 shared publication
Latest Publications
- 1 January 1996
- Published by AACN Publishing in American Journal of Critical Care
- Vol. 5 (1) , 26-33
Cardiac dysrhythmia during sleep in the critically ill: a pilot study
BACKGROUND: Few investigators have examined the hemodynamic status related to circadian and sleep-related cardiovascular events in critically ill patients. OBJECTIVE: To describe the relationships among nocturnal angina, myocardial infarction, and sleep, and to describe the cardiac rhythm, heart rate, and frequency of premature supraventricular and ventricular contractions during the sleep of critical care patients with cardiovascular disease. METHODS: A descriptive survey was done on nine patients in the medical intensive care unit of a large medical center. All subjects had cardiovascular disease and were studied during one night of sleep. RESULTS: There were no incidences of chest pain during the study and no changes in baseline cardiac rhythm associated with sleep staging. There was a significant statistical difference in mean heart rate among waking, stage 1 nonrapid-eye-movement sleep, and stage 2 nonrapid-eye-movement sleep; a lower heart rate was observed in stage 2 nonrapid-eye-movement sleep. The mean heart rate decreased by 3% to 4% from the waking state to sleep. No clinical or statistically significant differences in the frequency of premature supraventricular and ventricular contractions between sleep stages or sleeping and waking were found. CONCLUSIONS: The results of this pilot investigation do not suggest that dysrhythmia occurs more frequently during certain sleep stages or during the sleep state in critical care unit patients with cardiovascular disease. The mean heart rate slowed by 3% to 4% during rapid-eye-movement and nonrapid-eye-movement sleep, but decreases in heart rate were not as great as those noted in normal, healthy subjects.
- 1 January 1996
- Published by AACN Publishing in American Journal of Critical Care
- Vol. 5 (1) , 26-33
Cardiac dysrhythmia during sleep in the critically ill: a pilot study
BACKGROUND: Few investigators have examined the hemodynamic status related to circadian and sleep-related cardiovascular events in critically ill patients. OBJECTIVE: To describe the relationships among nocturnal angina, myocardial infarction, and sleep, and to describe the cardiac rhythm, heart rate, and frequency of premature supraventricular and ventricular contractions during the sleep of critical care patients with cardiovascular disease. METHODS: A descriptive survey was done on nine patients in the medical intensive care unit of a large medical center. All subjects had cardiovascular disease and were studied during one night of sleep. RESULTS: There were no incidences of chest pain during the study and no changes in baseline cardiac rhythm associated with sleep staging. There was a significant statistical difference in mean heart rate among waking, stage 1 nonrapid-eye-movement sleep, and stage 2 nonrapid-eye-movement sleep; a lower heart rate was observed in stage 2 nonrapid-eye-movement sleep. The mean heart rate decreased by 3% to 4% from the waking state to sleep. No clinical or statistically significant differences in the frequency of premature supraventricular and ventricular contractions between sleep stages or sleeping and waking were found. CONCLUSIONS: The results of this pilot investigation do not suggest that dysrhythmia occurs more frequently during certain sleep stages or during the sleep state in critical care unit patients with cardiovascular disease. The mean heart rate slowed by 3% to 4% during rapid-eye-movement and nonrapid-eye-movement sleep, but decreases in heart rate were not as great as those noted in normal, healthy subjects.
- 1 January 1996
- Published by AACN Publishing in American Journal of Critical Care
- Vol. 5 (1) , 68-73
Development of a model of advanced practice
BACKGROUND: The acute care nurse practitioner role is relatively new and not yet clearly defined. Our institution is in the first phase of a role delineation study that includes model development, validity testing, model revision, and dissemination. OBJECTIVES: To identify domains of practice, activities within each domain of practice, and common conceptual strands that cut across each domain, and to synthesize this information into a usable format to guide practice and role development. METHODS: A nonexperimental study design was used, including review of literature, expert consultation, brainstorming, and review of practice. RESULTS: The patient is central to the model. The identified domains of practice include direct comprehensive care, support of systems, education, research, and publication, and professional leadership. The conceptual strands include empowerment, collaboration, and scholarship. A continuum of experience from novice to expert was also identified within each domain. CONCLUSIONS: The development of the model is the first and most important phase in the role-delineation process. We believe that the model is accurate but still in need of testing. Nevertheless, our model can be used to guide institutions and individual practitioners.
- 1 January 1996
- Published by AACN Publishing in American Journal of Critical Care
- Vol. 5 (1) , 68-73
Development of a model of advanced practice
BACKGROUND: The acute care nurse practitioner role is relatively new and not yet clearly defined. Our institution is in the first phase of a role delineation study that includes model development, validity testing, model revision, and dissemination. OBJECTIVES: To identify domains of practice, activities within each domain of practice, and common conceptual strands that cut across each domain, and to synthesize this information into a usable format to guide practice and role development. METHODS: A nonexperimental study design was used, including review of literature, expert consultation, brainstorming, and review of practice. RESULTS: The patient is central to the model. The identified domains of practice include direct comprehensive care, support of systems, education, research, and publication, and professional leadership. The conceptual strands include empowerment, collaboration, and scholarship. A continuum of experience from novice to expert was also identified within each domain. CONCLUSIONS: The development of the model is the first and most important phase in the role-delineation process. We believe that the model is accurate but still in need of testing. Nevertheless, our model can be used to guide institutions and individual practitioners.
- 1 January 1996
- Published by AACN Publishing in American Journal of Critical Care
- Vol. 5 (1) , 55-65
Emerging technology in critical care: continuous intra-arterial blood gas monitoring
The blood-conserving technology of continuous intra-arterial blood gas monitoring has recently been introduced into the field of critical care. This type of monitoring is a real-time method for concomitantly assessing oxygenation, ventilation, and acid-base status in pediatric and adult populations through an indwelling (in vivo) sensor residing in a peripheral artery. This article examines the technology underpinning in vivo blood gas monitoring and reviews research documenting clinical performance, as well as benefits and clinical applications of three-analyte systems in critically ill patients. A majority of research has revealed clinically acceptable accuracy and reliability of in vivo blood gas sensors in critically ill adults subjected to a variety of adverse, but common, physiological conditions. Although most clinical research in critically ill adults has revealed good clinical performance of in vivo blood gas sensors, reports of aberrant blood gas values and sensor problems remain; no reports have been published to date evaluating continuous intra-arterial blood gas monitoring in children or infants. Many benefits of this technology have been postulated, and research examining its effect on patient and cost outcomes in critically ill populations is pending. Clinicians in critical care must keep abreast of this emerging technology, because it holds significant potential for improving the quality of care and outcomes of critically ill patients.
- 1 January 1996
- Published by AACN Publishing in American Journal of Critical Care
- Vol. 5 (1) , 55-65
Emerging technology in critical care: continuous intra-arterial blood gas monitoring
The blood-conserving technology of continuous intra-arterial blood gas monitoring has recently been introduced into the field of critical care. This type of monitoring is a real-time method for concomitantly assessing oxygenation, ventilation, and acid-base status in pediatric and adult populations through an indwelling (in vivo) sensor residing in a peripheral artery. This article examines the technology underpinning in vivo blood gas monitoring and reviews research documenting clinical performance, as well as benefits and clinical applications of three-analyte systems in critically ill patients. A majority of research has revealed clinically acceptable accuracy and reliability of in vivo blood gas sensors in critically ill adults subjected to a variety of adverse, but common, physiological conditions. Although most clinical research in critically ill adults has revealed good clinical performance of in vivo blood gas sensors, reports of aberrant blood gas values and sensor problems remain; no reports have been published to date evaluating continuous intra-arterial blood gas monitoring in children or infants. Many benefits of this technology have been postulated, and research examining its effect on patient and cost outcomes in critically ill populations is pending. Clinicians in critical care must keep abreast of this emerging technology, because it holds significant potential for improving the quality of care and outcomes of critically ill patients.
- 1 January 1996
- Published by AACN Publishing in American Journal of Critical Care
- Vol. 5 (1) , 66-67
Fluid delivery by pressure monitoring systems in the pediatric intensive care unit: a retrospective comparative analysis of two systems
- 1 January 1996
- Published by AACN Publishing in American Journal of Critical Care
- Vol. 5 (1) , 66-67
Fluid delivery by pressure monitoring systems in the pediatric intensive care unit: a retrospective comparative analysis of two systems
- 1 January 1996
- Published by AACN Publishing in American Journal of Critical Care
- Vol. 5 (1) , 42-48
Effectiveness of a jet injection system in administering morphine and heparin to healthy adults
BACKGROUND: Jet injection eliminates the risk of contaminated needlestick injuries when giving intramuscular or subcutaneous medications. Clinical efficacy of the Biojector System was equivalent to that of needle and syringe injection in unpublished trials with vaccines, but had not been studied using other drugs. OBJECTIVE: To compare the effectiveness of the Biojector with conventional needle and syringe injection in administering intramuscular morphine and subcutaneous heparin to healthy adults, as measured by plasma drug concentration. METHODS: Intramuscular injections of morphine 8 mg (5 mg if weight < or = 65 kg) were given 24 hours apart with the jet injector and with a needle and syringe to 30 subjects at the deltoid site and 10 subjects at the dorsogluteal site. Blood samples for plasma concentrations of free morphine were drawn at 15, 30, 45, 60, 120, and 240 minutes and were analyzed using radioimmunoassay. Abdominal subcutaneous injections of heparin 3500 U were given every 8 hours for 5 days with both injection methods to 29 subjects, with 48 hours between the two series. Daily blood samples for plasma heparin were analyzed by colorimetric assay for antifactor Xa activity. RESULTS: Mean free morphine concentration, peak value, and area under the curve did not differ significantly between the deltoid and dorsogluteal sites or between the jet injector and needle and syringe. Values of mean daily heparin concentrations and area under the curve were low and did not differ between the two injection methods. CONCLUSION: Plasma drug concentrations provided by the Biojector were equivalent to those provided by conventional needle and syringe when administering intramuscular morphine and low-dose subcutaneous heparin.
- 1 January 1996
- Published by AACN Publishing in American Journal of Critical Care
- Vol. 5 (1) , 42-48
Effectiveness of a jet injection system in administering morphine and heparin to healthy adults
BACKGROUND: Jet injection eliminates the risk of contaminated needlestick injuries when giving intramuscular or subcutaneous medications. Clinical efficacy of the Biojector System was equivalent to that of needle and syringe injection in unpublished trials with vaccines, but had not been studied using other drugs. OBJECTIVE: To compare the effectiveness of the Biojector with conventional needle and syringe injection in administering intramuscular morphine and subcutaneous heparin to healthy adults, as measured by plasma drug concentration. METHODS: Intramuscular injections of morphine 8 mg (5 mg if weight < or = 65 kg) were given 24 hours apart with the jet injector and with a needle and syringe to 30 subjects at the deltoid site and 10 subjects at the dorsogluteal site. Blood samples for plasma concentrations of free morphine were drawn at 15, 30, 45, 60, 120, and 240 minutes and were analyzed using radioimmunoassay. Abdominal subcutaneous injections of heparin 3500 U were given every 8 hours for 5 days with both injection methods to 29 subjects, with 48 hours between the two series. Daily blood samples for plasma heparin were analyzed by colorimetric assay for antifactor Xa activity. RESULTS: Mean free morphine concentration, peak value, and area under the curve did not differ significantly between the deltoid and dorsogluteal sites or between the jet injector and needle and syringe. Values of mean daily heparin concentrations and area under the curve were low and did not differ between the two injection methods. CONCLUSION: Plasma drug concentrations provided by the Biojector were equivalent to those provided by conventional needle and syringe when administering intramuscular morphine and low-dose subcutaneous heparin.