Ali Sadoughi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ali Sadoughi has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
Sahil Virdi
Division of pulmonary and critical care, United Hospital Center, West Virginia University Health System, Charleston, USA
2 shared publicationsAbhishek Sarkar
Section of Interventional Pulmonology, Department of Pulmonary, Critical Care, and Sleep Medicine, Westchester Medical Center / New York Medical College, Valhalla, USA
1 shared publication- Abhishek Sarkar
Interventional Pulmonology, Medicine, Westchester Medical Center, Valhalla, United States, USA
1 shared publication - Adrish Sarkar
Department of Radiology, Nassau University Medical Center, East Meadow, NY 11554, USA
1 shared publication - Aham Okorozo
Pulmonary Division-Department of Medicine, Montefiore Medical Center-Albert Einstein College of Medicine, Bronx, NY, USA
1 shared publication - Anant Jain
Pulmonary and Critical Care, Westchester Medical Center, Valhalla, NY, United States
1 shared publication
Latest Publications
- Open Access
- 7 April 2025
- Published by Elsevier in CHEST Pulmonary
- Vol. 3 (2)
A 53-Year-Old Female With Dyspnea and Hemoptysis
- 7 April 2025
- Published by Elsevier in CHEST Pulmonary
- Vol. 3 (2)
Open AccessA 53-Year-Old Female With Dyspnea and Hemoptysis
- Open Access
- 12 June 2024
- Published by Springer Nature in Lung
- Vol. 202 (5) , 601-613
Ultrathin Bronchoscopy Without Virtual Navigation for Diagnosis of Peripheral Lung Lesions
Background: The increasing incidence of encountering lung nodules necessitates an ongoing search for improved diagnostic procedures. Various bronchoscopic technologies have been introduced or are in development, but further studies are needed to define a method that fits best in clinical practice and health care systems. Research question: How do basic bronchoscopic tools including a combination of thin (outer diameter 4.2 mm) and ultrathin bronchoscopes (outer diameter 3.0 mm), radial endobronchial ultrasound (rEBUS) and fluoroscopy perform in peripheral pulmonary lesion diagnosis? Study Design and Methods: This is a retrospective review of the performance of peripheral bronchoscopy using thin and ultrathin bronchoscopy with rEBUS and 2D fluoroscopy without a navigational system for evaluating peripheral lung lesions in a single academic medical center from 11/2015 to 1/2021. We used a strict definition for diagnostic yield and assessed the impact of different variables on diagnostic yield, specifically after employment of the ultrathin bronchoscope. Logistic regression models were employed to assess the independent associations of the most impactful variables. Results: A total of 322 patients were included in this study. The median of the long axis diameter was 2.2 cm and the median distance of the center of the lesion from the visceral pleural surface was 1.9 cm. Overall diagnostic yield was 81.3% after employment of the ultrathin bronchoscope, with more detection of concentric rEBUS views (93% vs. 78%, p < 0.001). Sensitivity for detecting malignancy also increased from 60.5% to 74.7% (p = 0.033) after incorporating the ultrathin scope into practice, while bronchus sign and peripheral location of the lesion were not found to affect diagnostic yield. Concentric rEBUS view, solid appearance, upper/middle lobe location and larger size of the nodules were found to be independent predictors of successful achievement of diagnosis at bronchoscopy. Interpretation: This study demonstrates a high diagnostic yield of biopsy of lung lesions achieved by utilization of thin and ultrathin bronchoscopes. Direct visualization of small peripheral airways with simultaneous rEBUS confirmation increased localization rate of small lesions in a conventional bronchoscopy setting without virtual navigational planning.
- 12 June 2024
- Published by Springer Nature in Lung
- Vol. 202 (5) , 601-613
Open AccessUltrathin Bronchoscopy Without Virtual Navigation for Diagnosis of Peripheral Lung Lesions
Background: The increasing incidence of encountering lung nodules necessitates an ongoing search for improved diagnostic procedures. Various bronchoscopic technologies have been introduced or are in development, but further studies are needed to define a method that fits best in clinical practice and health care systems. Research question: How do basic bronchoscopic tools including a combination of thin (outer diameter 4.2 mm) and ultrathin bronchoscopes (outer diameter 3.0 mm), radial endobronchial ultrasound (rEBUS) and fluoroscopy perform in peripheral pulmonary lesion diagnosis? Study Design and Methods: This is a retrospective review of the performance of peripheral bronchoscopy using thin and ultrathin bronchoscopy with rEBUS and 2D fluoroscopy without a navigational system for evaluating peripheral lung lesions in a single academic medical center from 11/2015 to 1/2021. We used a strict definition for diagnostic yield and assessed the impact of different variables on diagnostic yield, specifically after employment of the ultrathin bronchoscope. Logistic regression models were employed to assess the independent associations of the most impactful variables. Results: A total of 322 patients were included in this study. The median of the long axis diameter was 2.2 cm and the median distance of the center of the lesion from the visceral pleural surface was 1.9 cm. Overall diagnostic yield was 81.3% after employment of the ultrathin bronchoscope, with more detection of concentric rEBUS views (93% vs. 78%, p < 0.001). Sensitivity for detecting malignancy also increased from 60.5% to 74.7% (p = 0.033) after incorporating the ultrathin scope into practice, while bronchus sign and peripheral location of the lesion were not found to affect diagnostic yield. Concentric rEBUS view, solid appearance, upper/middle lobe location and larger size of the nodules were found to be independent predictors of successful achievement of diagnosis at bronchoscopy. Interpretation: This study demonstrates a high diagnostic yield of biopsy of lung lesions achieved by utilization of thin and ultrathin bronchoscopes. Direct visualization of small peripheral airways with simultaneous rEBUS confirmation increased localization rate of small lesions in a conventional bronchoscopy setting without virtual navigational planning.
- Open Access
- 3 August 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (15) , 2580
Digital Tomosynthesis: Review of Current Literature and Its Impact on Diagnostic Bronchoscopy
Bronchoscopy has garnered increased popularity in the biopsy of peripheral lung lesions. The development of navigational guided bronchoscopy systems along with radial endobronchial ultrasound (REBUS) allows clinicians to access and sample peripheral lesions. The development of robotic bronchoscopy improved localization of targets and diagnostic accuracy. Despite such technological advancements, published diagnostic yield remains lower compared to computer tomography (CT)-guided biopsy. The discordance between the real-time location of peripheral lesions and anticipated location from preplanned navigation software is often cited as the main variable impacting accurate biopsies. The utilization of cone beam CT (CBCT) with navigation-based bronchoscopy has been shown to assist with localizing targets in real-time and improving biopsy success. The resources, costs, and radiation associated with CBCT remains a hindrance in its wider adoption. Recently, digital tomosynthesis (DT) platforms have been developed as an alternative for real-time imaging guidance in peripheral lung lesions. In North America, there are several commercial platforms with distinct features and adaptation of DT. Early studies show the potential improvement in peripheral lesion sampling with DT. Despite the results of early observational studies, the true impact of DT-based imaging devices for peripheral lesion sampling cannot be determined without further prospective randomized trials and meta-analyses.
- 3 August 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (15) , 2580
Open AccessDigital Tomosynthesis: Review of Current Literature and Its Impact on Diagnostic Bronchoscopy
Bronchoscopy has garnered increased popularity in the biopsy of peripheral lung lesions. The development of navigational guided bronchoscopy systems along with radial endobronchial ultrasound (REBUS) allows clinicians to access and sample peripheral lesions. The development of robotic bronchoscopy improved localization of targets and diagnostic accuracy. Despite such technological advancements, published diagnostic yield remains lower compared to computer tomography (CT)-guided biopsy. The discordance between the real-time location of peripheral lesions and anticipated location from preplanned navigation software is often cited as the main variable impacting accurate biopsies. The utilization of cone beam CT (CBCT) with navigation-based bronchoscopy has been shown to assist with localizing targets in real-time and improving biopsy success. The resources, costs, and radiation associated with CBCT remains a hindrance in its wider adoption. Recently, digital tomosynthesis (DT) platforms have been developed as an alternative for real-time imaging guidance in peripheral lung lesions. In North America, there are several commercial platforms with distinct features and adaptation of DT. Early studies show the potential improvement in peripheral lesion sampling with DT. Despite the results of early observational studies, the true impact of DT-based imaging devices for peripheral lesion sampling cannot be determined without further prospective randomized trials and meta-analyses.
- Open Access
- 16 September 2020
- Published by Wolters Kluwer Health in Journal of Bronchology & Interventional Pulmonology
- Vol. 28 (1) , 76-80
Mobile 3D Intraprocedural Fluoroscopy in Combination With Ultrathin Bronchoscopy for Biopsy of Peripheral Lung Nodules
Despite development of multiple technologies, distinguishing benign from malignant lung nodules when they are still small in size is challenging. A high yield and minimally invasive bronchoscopic technology with low cost for diagnosis of small lung lesions is needed in pulmonary and lung cancer clinical practice. Peripheral airway bronchoscopy using thin and most recently ultrathin bronchoscopes improve visualization of small airways. The novel mobile 2D/3D C-Arm fluoroscopy system is a complementary tool along with radial endobronchial ultrasound in detecting small lung nodules with real-time high-quality multidimensional image confirmation during bronchoscopy. This combined technology can be easily acquired in any bronchoscopy room, and potentially affect lung nodule practice significantly.
- 16 September 2020
- Published by Wolters Kluwer Health in Journal of Bronchology & Interventional Pulmonology
- Vol. 28 (1) , 76-80
Open AccessMobile 3D Intraprocedural Fluoroscopy in Combination With Ultrathin Bronchoscopy for Biopsy of Peripheral Lung Nodules
Despite development of multiple technologies, distinguishing benign from malignant lung nodules when they are still small in size is challenging. A high yield and minimally invasive bronchoscopic technology with low cost for diagnosis of small lung lesions is needed in pulmonary and lung cancer clinical practice. Peripheral airway bronchoscopy using thin and most recently ultrathin bronchoscopes improve visualization of small airways. The novel mobile 2D/3D C-Arm fluoroscopy system is a complementary tool along with radial endobronchial ultrasound in detecting small lung nodules with real-time high-quality multidimensional image confirmation during bronchoscopy. This combined technology can be easily acquired in any bronchoscopy room, and potentially affect lung nodule practice significantly.
- Open Access
- 1 May 2020
- Published by Oxford University Press (OUP)
- p. A4890
Lobar and Segmental Bronchi Stenting: A Way to Improve Functional Capacity
- 1 May 2020
- Published by Oxford University Press (OUP)
- p. A4890
Open AccessLobar and Segmental Bronchi Stenting: A Way to Improve Functional Capacity