Durjoy Deb Dhruba
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Durjoy Deb Dhruba has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Sarv Priya
Department of Radiology University of Wisconsin Madison Wisconsin USA
2 shared publications - Aida Karami
Department of Medical Imaging and Radiation Sciences, School of Allied Medical Sciences Ahvaz Jundishapur University of Medical Sciences Ahvaz Iran
1 shared publication - Ali Fatemi
Department of Physics Jackson State University Jackson Mississippi USA
1 shared publication Blake A Kassmeyer
Division of Clinical Trials and Biostatistics, Department of Quantitative Health Sciences, Mayo Clinic, 200 1st Street SW, Rochester, MN 55902, USA
1 shared publication- Douglas Roberts-Wolfe
Department of Radiology, Perelman School of Medicine, University of Pennsylvania, 3400 Spruce Street, Philadelphia, PA 19104 USA
1 shared publication - Eldon Sorensen
Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)
1 shared publication
Latest Publications
- Open Access
- 19 November 2024
- Published by Wiley in Health Science Reports
- Vol. 7 (11) , e70172
Optimizing Multiparametric MRI Protocols for Prostate Cancer Detection: A Comprehensive Assessment Aligned with PI‐RADS Guidelines
Background and Aim: Multiparametric magnetic resonance imaging (mpMRI) is recognized as the most indicative method for diagnosing prostate cancer. The purpose of this narrative review is to provide a comprehensive evaluation aligned with the Prostate Imaging and Reporting Data System (PI‐RADS) guidelines, offering an in‐depth insight into the various MRI sequences used in a standard mpMRI protocol. Additionally, it outlines the critical technical requirements necessary to perform a standard mpMRI examination of the prostate, as defined by the PI‐RADS specifications.Methods: European Society of Urogenital Radiology has released PI‐RADS guideline detailing its suggestions aimed at improving the standards of the procedure. The purpose of this guideline is to establish a standard strategy for MRI protocols and image interpretation, aiming to prevent variability in each of the imaging and interpretation stages.Results: A standard mpMRI protocol comprises morphological sequences and functional sequences. Morphological sequences which encompass T1‐ and T2‐weighted images, and various functional sequences include diffusion‐weighted imaging, and dynamic contrast‐enhanced MRI. The PI‐RADS recommendations assert that having a standard and uniform protocol for all MRI centers is imperative. Furthermore, the existence of a standardized checklist for interpreting MRI images can foster greater consensus in the process of diagnosing and treating patients.Conclusion: Standardized protocols and checklists for mpMRI interpretation are essential for achieving greater consensus among radiologists, ultimately leading to improved diagnostic outcomes in prostate cancer.
- 19 November 2024
- Published by Wiley in Health Science Reports
- Vol. 7 (11) , e70172
Open AccessOptimizing Multiparametric MRI Protocols for Prostate Cancer Detection: A Comprehensive Assessment Aligned with PI‐RADS Guidelines
Background and Aim: Multiparametric magnetic resonance imaging (mpMRI) is recognized as the most indicative method for diagnosing prostate cancer. The purpose of this narrative review is to provide a comprehensive evaluation aligned with the Prostate Imaging and Reporting Data System (PI‐RADS) guidelines, offering an in‐depth insight into the various MRI sequences used in a standard mpMRI protocol. Additionally, it outlines the critical technical requirements necessary to perform a standard mpMRI examination of the prostate, as defined by the PI‐RADS specifications.Methods: European Society of Urogenital Radiology has released PI‐RADS guideline detailing its suggestions aimed at improving the standards of the procedure. The purpose of this guideline is to establish a standard strategy for MRI protocols and image interpretation, aiming to prevent variability in each of the imaging and interpretation stages.Results: A standard mpMRI protocol comprises morphological sequences and functional sequences. Morphological sequences which encompass T1‐ and T2‐weighted images, and various functional sequences include diffusion‐weighted imaging, and dynamic contrast‐enhanced MRI. The PI‐RADS recommendations assert that having a standard and uniform protocol for all MRI centers is imperative. Furthermore, the existence of a standardized checklist for interpreting MRI images can foster greater consensus in the process of diagnosing and treating patients.Conclusion: Standardized protocols and checklists for mpMRI interpretation are essential for achieving greater consensus among radiologists, ultimately leading to improved diagnostic outcomes in prostate cancer.
- 29 August 2023
- Published by Elsevier in Journal Of Neuroradiology
- Vol. 51 (3) , 258-264
AI-based classification of three common malignant tumors in neuro-oncology: A multi-institutional comparison of machine learning and deep learning methods
- 29 August 2023
- Published by Elsevier in Journal Of Neuroradiology
- Vol. 51 (3) , 258-264
AI-based classification of three common malignant tumors in neuro-oncology: A multi-institutional comparison of machine learning and deep learning methods
- 1 August 2023
- Published by Radiological Society of North America (RSNA) in Radiology: Cardiothoracic Imaging
- Vol. 5 (4) , e220312
ComBat Harmonization of Myocardial Radiomic Features Sensitive to Cardiac MRI Acquisition Parameters
To investigate the effect of ComBat harmonization methods on the robustness of cardiac MRI–derived radiomic features to variations in imaging parameters. This Health Insurance Portability and Accountability Act–compliant retrospective study used a publicly available data set of 11 healthy controls (mean age, 33 years ± 16 [SD]; six men) and five patients (mean age, 52 years ± 16; four men). A single midventricular short-axis section was acquired with 3-T MRI using cine balanced steady-state free precision, T1-weighted, T2-weighted, T1 mapping, and T2 mapping imaging sequences. Each sequence was acquired using baseline parameters and after variations in flip angle, spatial resolution, section thickness, and parallel imaging. Image registration was performed for all sequences at a per-individual level. Manual myocardial contouring was performed, and 1652 radiomic features per sequence were extracted using baseline and variations in imaging parameters. Radiomic feature stability to change in imaging parameters was assessed using Cohen d sensitivity. The stability of radiomic features was assessed both without and after ComBat harmonization of radiomic features. Three ComBat methods were studied: parametric, nonparametric, and Gaussian mixture model (GMM). For all sequences combined, 51.4% of features were robust to changes in imaging parameters when no ComBat method was applied. ComBat harmonization substantially increased the number of stable features to 95.1% (95% CI: 94.9, 95.3) when parametric ComBat was used and 90.9% (95% CI: 90.6, 91.2) when nonparametric ComBat was used. GMM combat resulted in only 52.6% stable features. ComBat harmonization improved the stability of radiomic features to changes in imaging parameters across all cardiac MRI sequences. Keywords: Cardiac MRI, Radiomics, ComBat, Harmonization Supplemental material is available for this article. © RSNA, 2023
- 1 August 2023
- Published by Radiological Society of North America (RSNA) in Radiology: Cardiothoracic Imaging
- Vol. 5 (4) , e220312
ComBat Harmonization of Myocardial Radiomic Features Sensitive to Cardiac MRI Acquisition Parameters
To investigate the effect of ComBat harmonization methods on the robustness of cardiac MRI–derived radiomic features to variations in imaging parameters. This Health Insurance Portability and Accountability Act–compliant retrospective study used a publicly available data set of 11 healthy controls (mean age, 33 years ± 16 [SD]; six men) and five patients (mean age, 52 years ± 16; four men). A single midventricular short-axis section was acquired with 3-T MRI using cine balanced steady-state free precision, T1-weighted, T2-weighted, T1 mapping, and T2 mapping imaging sequences. Each sequence was acquired using baseline parameters and after variations in flip angle, spatial resolution, section thickness, and parallel imaging. Image registration was performed for all sequences at a per-individual level. Manual myocardial contouring was performed, and 1652 radiomic features per sequence were extracted using baseline and variations in imaging parameters. Radiomic feature stability to change in imaging parameters was assessed using Cohen d sensitivity. The stability of radiomic features was assessed both without and after ComBat harmonization of radiomic features. Three ComBat methods were studied: parametric, nonparametric, and Gaussian mixture model (GMM). For all sequences combined, 51.4% of features were robust to changes in imaging parameters when no ComBat method was applied. ComBat harmonization substantially increased the number of stable features to 95.1% (95% CI: 94.9, 95.3) when parametric ComBat was used and 90.9% (95% CI: 90.6, 91.2) when nonparametric ComBat was used. GMM combat resulted in only 52.6% stable features. ComBat harmonization improved the stability of radiomic features to changes in imaging parameters across all cardiac MRI sequences. Keywords: Cardiac MRI, Radiomics, ComBat, Harmonization Supplemental material is available for this article. © RSNA, 2023