Ilya O. Bokatyi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ilya O. Bokatyi has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Aleksandr Titov
Peter the Great St. Petersburg Polytechnic University
1 shared publication - Alexander N. Timofeev
ITMO University, St. Petersburg, Russia
1 shared publication Andrei V. Radilov
1 shared publication- G.E. Romanova1 shared publication
- Galina E. Romanova
ITMO University
1 shared publication Valery V. Korotaev
ITMO Univ. (Russian Federation)
1 shared publication
Latest Publications
- 1 July 2022
- Published by Optica Publishing Group in Journal of Optical Technology
- Vol. 90 (7) , 376-383
Scintillation optical-electronic converter of gamma radiation based on a silicon photomultiplier
Subject of study. This study is focused on a scintillation optical-electronic converter of gamma radiation based on a silicon photomultiplier. Purpose of the work. This study was carried out to develop an optical-electronic converter of gamma radiation for personal use and operation as part of distributed radiation monitoring systems, under mechanical influences and electromagnetic fields and with an increased transfer characteristic linearity range and improved relative energy resolution. Method. An analysis of the signal-conversion processes in a scintillation optical-electronic converter of gamma radiation is carried out, and a computer simulation and experimental study of the converter are also performed. Main results. The optical-electronic gamma-radiation converter was developed for personal use and operation as part of the distributed radiation monitoring systems in the field. A method for selecting the dimensions of the optical system for the matching of a scintillation crystal and a silicon photomultiplier in addition to the type and parameters of its reflective surfaces was developed, which made it possible to increase the linearity range of the converter transfer characteristic by increasing the uniformity of the photomultiplier irradiation. An algorithm is proposed for estimating the contribution of signal losses from photons arriving at a microcell of a silicon photomultiplier during the restoration of its sensitivity to the relative energy resolution of the converter in experimental studies of the uniformity of irradiation distribution. Practical significance. An optical-electronic converter of gamma radiation has been developed with an increase in the linearity range of the transfer characteristic of up to two times with an integral nonlinearity of the energy characteristic of no more than 1% and an improved relative energy resolution by at least 10% for the peak energy of 662 keV of the reference 137Cs source. The optical-electronic converter is designed for personal use and operation as part of distributed radiation monitoring systems in the field.
- 1 July 2022
- Published by Optica Publishing Group in Journal of Optical Technology
- Vol. 90 (7) , 376-383
Scintillation optical-electronic converter of gamma radiation based on a silicon photomultiplier
Subject of study. This study is focused on a scintillation optical-electronic converter of gamma radiation based on a silicon photomultiplier. Purpose of the work. This study was carried out to develop an optical-electronic converter of gamma radiation for personal use and operation as part of distributed radiation monitoring systems, under mechanical influences and electromagnetic fields and with an increased transfer characteristic linearity range and improved relative energy resolution. Method. An analysis of the signal-conversion processes in a scintillation optical-electronic converter of gamma radiation is carried out, and a computer simulation and experimental study of the converter are also performed. Main results. The optical-electronic gamma-radiation converter was developed for personal use and operation as part of the distributed radiation monitoring systems in the field. A method for selecting the dimensions of the optical system for the matching of a scintillation crystal and a silicon photomultiplier in addition to the type and parameters of its reflective surfaces was developed, which made it possible to increase the linearity range of the converter transfer characteristic by increasing the uniformity of the photomultiplier irradiation. An algorithm is proposed for estimating the contribution of signal losses from photons arriving at a microcell of a silicon photomultiplier during the restoration of its sensitivity to the relative energy resolution of the converter in experimental studies of the uniformity of irradiation distribution. Practical significance. An optical-electronic converter of gamma radiation has been developed with an increase in the linearity range of the transfer characteristic of up to two times with an integral nonlinearity of the energy characteristic of no more than 1% and an improved relative energy resolution by at least 10% for the peak energy of 662 keV of the reference 137Cs source. The optical-electronic converter is designed for personal use and operation as part of distributed radiation monitoring systems in the field.
- Open Access
- 1 April 2020
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11367, 53
Principles of developing of a scintillation detector based on SiPM for a field gamma-spectrometry problems
Spectral methods for the detection and analysis of ionizing radiation sources are widely used in many fields of science and technology. Ecology, geology and mineralogy, metallurgy and the chemical industry, the oil industry and medicine - this is not the whole list of areas where the gamma-ray spectrometer acts as an independent software and hardware tool. Scintillation spectrometers are used to monitor the radiation environment, to search for sources of ionizing radiation, tomography and much more. However, this method is based on the use of vacuum photoelectronic multipliers (PMTs), which complicates the use of devices in the field. This article presents an analysis of gamma-ray scintillation spectrometers built on the basis of silicon photoelectronic multipliers (SiPM). The fields of application of field gamma spectrometers are considered and the basic requirements that the devices must meet to ensure the successful solution of the tasks are determined. The basic principles of the development of field scintillation gamma spectrometers that take into account the processes and transformations of the optical range radiation inside the detector are described. Moreover, the article describes personal experience in the development of an experimental sample of a field gamma spectrometer based on SiPM. In this article, the use of field device refers to any use outside of laboratory conditions.
- 1 April 2020
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11367, 53
Open AccessPrinciples of developing of a scintillation detector based on SiPM for a field gamma-spectrometry problems
Spectral methods for the detection and analysis of ionizing radiation sources are widely used in many fields of science and technology. Ecology, geology and mineralogy, metallurgy and the chemical industry, the oil industry and medicine - this is not the whole list of areas where the gamma-ray spectrometer acts as an independent software and hardware tool. Scintillation spectrometers are used to monitor the radiation environment, to search for sources of ionizing radiation, tomography and much more. However, this method is based on the use of vacuum photoelectronic multipliers (PMTs), which complicates the use of devices in the field. This article presents an analysis of gamma-ray scintillation spectrometers built on the basis of silicon photoelectronic multipliers (SiPM). The fields of application of field gamma spectrometers are considered and the basic requirements that the devices must meet to ensure the successful solution of the tasks are determined. The basic principles of the development of field scintillation gamma spectrometers that take into account the processes and transformations of the optical range radiation inside the detector are described. Moreover, the article describes personal experience in the development of an experimental sample of a field gamma spectrometer based on SiPM. In this article, the use of field device refers to any use outside of laboratory conditions.
- Open Access
- 1 November 2018
- Published by ITMO University in Scientific and Technical Journal of Information Technologies, Mechanics and Optics
- Vol. 18 (6) , 932-938
Computer simulation of gamma-ray detector based on scintillation crystals and silicon photomultipliers
Subject of Research. The paper considers the principles of realization of the gamma-radiation detector based on a silicon photoelectron multiplier and a scintillation crystal with the use of an optical matching scheme. Method. For studying the possible variants of detector creation, computer models were developed in the ZEMAX Software environment, describing radiation propagation process of scintillation in the crystal volume in view of the main processes taking place in the scintillation detector. The model has the same optical characteristics as cesium iodide (CsI). Main Results. Quantitative parameters of the signal and radiation losses in modeled systems were obtained. The information on radiation distribution in the photodetector plane was obtained as well. The optimal sheme for detector creation from the registration effectiveness point of view was established and its geometric parameters were determined. Practical Relevance. The development of the approach gives the possibility to solve the problem of creating highly efficient and miniature scintillation detectors at the expense of a new class of photodetectors - silicon photoelectric multipliers. The results of the research will be useful in the development of scintillation gamma spectrometers and other devices with operating principles based on the methods of scintillation spectrometry and radiometry
- 1 November 2018
- Published by ITMO University in Scientific and Technical Journal of Information Technologies, Mechanics and Optics
- Vol. 18 (6) , 932-938
Open AccessComputer simulation of gamma-ray detector based on scintillation crystals and silicon photomultipliers
Subject of Research. The paper considers the principles of realization of the gamma-radiation detector based on a silicon photoelectron multiplier and a scintillation crystal with the use of an optical matching scheme. Method. For studying the possible variants of detector creation, computer models were developed in the ZEMAX Software environment, describing radiation propagation process of scintillation in the crystal volume in view of the main processes taking place in the scintillation detector. The model has the same optical characteristics as cesium iodide (CsI). Main Results. Quantitative parameters of the signal and radiation losses in modeled systems were obtained. The information on radiation distribution in the photodetector plane was obtained as well. The optimal sheme for detector creation from the registration effectiveness point of view was established and its geometric parameters were determined. Practical Relevance. The development of the approach gives the possibility to solve the problem of creating highly efficient and miniature scintillation detectors at the expense of a new class of photodetectors - silicon photoelectric multipliers. The results of the research will be useful in the development of scintillation gamma spectrometers and other devices with operating principles based on the methods of scintillation spectrometry and radiometry