Miloš Banjac
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Miloš Banjac has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Branislav Petrović
Univerzitet u Beogradu, Mašinski fakultet
5 shared publications - Sandra Kovačević
Mašinski fakultet Univerziteta u Beogradu, Kraljice Marije 16, Beograd
4 shared publications - Marija Vasilev
Univerzitet u Beogradu, Mašinski fakultet
3 shared publications - Ivan Zlatanović
Faculty of Mechanical Engineering, University of Belgrade, Belgrade, Serbia
2 shared publications - Marko Mančić
University of Nis
2 shared publications - Nedžad R. Rudonja
Faculty of Mechanical Engineering, University of Belgrade, Belgrade, Serbia
2 shared publications
Latest Publications
- 23 October 2026
- Published by University Library in Kragujevac in Energija Ekonomija Ekologija
- Vol. 28 (2)
Tehnoekonomska analiza kompresionog i apsorpcionog sistema za solarno hlađenje
U radu je prikazana tehnoekonomska analiza rada i sprovedeno poređenje dva rashladna postrojenja kojima je moguće ostvariti tzv. solarno hlađenje: kompresionog rashladnog postrojenja i apsorpcionog rashladnog postrojenja. Energija sunčevog zračenja predstavlja primarni energetski izvor za oba postrojenja. Razlike između sistema odnose se na način konverzije energije i princip ostvarivanja rashladnog procesa. Kod kompresionog rashladnog postrojenja solarna energija se konvertuje u električnu energiju primenom fotonaponskih prijemnika sunčeve energije, koja se zatim koristi za pogon kompresora. Kod apsorpcionog rashladnog postrojenja rashladni proces se ostvaruje korišćenjem toplote, koja se obezbeđuje pomoću termičkih prijemnika sunčeve energije. Radi obezbeđivanja uporedivosti rezultata, oba rashladna sistema analizirana su za istu nominalnu rashladnu snagu od 15 kW.
- 23 October 2026
- Published by University Library in Kragujevac in Energija Ekonomija Ekologija
- Vol. 28 (2)
Tehnoekonomska analiza kompresionog i apsorpcionog sistema za solarno hlađenje
U radu je prikazana tehnoekonomska analiza rada i sprovedeno poređenje dva rashladna postrojenja kojima je moguće ostvariti tzv. solarno hlađenje: kompresionog rashladnog postrojenja i apsorpcionog rashladnog postrojenja. Energija sunčevog zračenja predstavlja primarni energetski izvor za oba postrojenja. Razlike između sistema odnose se na način konverzije energije i princip ostvarivanja rashladnog procesa. Kod kompresionog rashladnog postrojenja solarna energija se konvertuje u električnu energiju primenom fotonaponskih prijemnika sunčeve energije, koja se zatim koristi za pogon kompresora. Kod apsorpcionog rashladnog postrojenja rashladni proces se ostvaruje korišćenjem toplote, koja se obezbeđuje pomoću termičkih prijemnika sunčeve energije. Radi obezbeđivanja uporedivosti rezultata, oba rashladna sistema analizirana su za istu nominalnu rashladnu snagu od 15 kW.
- 31 March 2026
- Published by University Library in Kragujevac in Energija Ekonomija Ekologija
- Vol. 28 (1)
Poređenje i analiza vrednosti koeficijenta transmisionih gubitaka toplote prema tlu određenog prema EN ISO 13790:2010 i EN ISO 13370:2017
U nameri da se ustanovi kolike razlike nastaju pri korišćenju u Srbiji trenutno aktuelnog proračuna za određivanje koeficijenta transmisionih gubitaka toplote prema tlu prema EN ISO 13790:2010, čija je upotreba propisana Pravilnikom o energetskoj efikasnosti zgrada („Sl. glasnik RS“, br. 61/2011) i proračuna prema standardu EN ISO 13370:2017, koga propisuje nova revidirana direktiva EPBD EU/2024/1275 u radu su predstavljene obe metode, a rezultati proračuna i odstupanja upoređeni i analizirani na konkretnom primeru. Između ostalog, ustanovljeno je da za razliku od prethodne mesečne/sezonske metode, utvrđene standardom EN ISO 13790, koja ne obuhvata inerciju tla, metoda iz standarda EN ISO 13370:2017 obuhvata ne samo razlike temperature zemljišta u odnosu na temperaturu spoljašnjeg vazduha, već i inertnost, tj. kašnjenje promene temperature tla u odnosu na temperaturu spoljašnjeg vazduha, što je čini superiornijom, a rezultate dobijene njenim korišćenjem kvalitetnijim i pouzdanijim.
- 31 March 2026
- Published by University Library in Kragujevac in Energija Ekonomija Ekologija
- Vol. 28 (1)
Poređenje i analiza vrednosti koeficijenta transmisionih gubitaka toplote prema tlu određenog prema EN ISO 13790:2010 i EN ISO 13370:2017
U nameri da se ustanovi kolike razlike nastaju pri korišćenju u Srbiji trenutno aktuelnog proračuna za određivanje koeficijenta transmisionih gubitaka toplote prema tlu prema EN ISO 13790:2010, čija je upotreba propisana Pravilnikom o energetskoj efikasnosti zgrada („Sl. glasnik RS“, br. 61/2011) i proračuna prema standardu EN ISO 13370:2017, koga propisuje nova revidirana direktiva EPBD EU/2024/1275 u radu su predstavljene obe metode, a rezultati proračuna i odstupanja upoređeni i analizirani na konkretnom primeru. Između ostalog, ustanovljeno je da za razliku od prethodne mesečne/sezonske metode, utvrđene standardom EN ISO 13790, koja ne obuhvata inerciju tla, metoda iz standarda EN ISO 13370:2017 obuhvata ne samo razlike temperature zemljišta u odnosu na temperaturu spoljašnjeg vazduha, već i inertnost, tj. kašnjenje promene temperature tla u odnosu na temperaturu spoljašnjeg vazduha, što je čini superiornijom, a rezultate dobijene njenim korišćenjem kvalitetnijim i pouzdanijim.
- 31 March 2026
- Published by University Library in Kragujevac in Energija Ekonomija Ekologija
- Vol. 28 (1)
Određivnje količine toplote akumulisane u zidu pri nestacionarnim promenama temperature spoljašnjeg vazduh
Iako standard EN ISO 13790:2010 „Energetske performanse zgrada – Proračun energije koja se koristi za grejanje i hlađenje“ definiše tri metode proračuna (kvazi-stacionarni mesečni metod i dva dinamička – jednostavan i detaljan časovni metod), trenutno važeći Pravilnik o energetskoj efikasnosti zgrada (Sl. glasnik RS, br. 61/2011) i dalje propisuje primenu najjednostavnijeg i najnepouzdanijeg kvazi-stacionarnog mesečnog metoda za određivanje godišnje potrebne količine toplote potrebne za grejanje zgrada. Ovaj pristup se zasniva na pretpostavci stacionarnog prolaženja toplote, pri čemu se zanemaruju vremenske promene temperature spoljašnjeg vazduha i efekti akumulacije toplote u građevinskim elementima, što može dovesti do značajnih odstupanja u proceni toplotnih gubitaka. Sa ciljem utvrđivanja greške koja nastaje primenom ova dva pristupa, u radu je izvršeno poređenje vrednosti toplotnih protoka dobijenih stacionarnim i nestacionarnim, odnosno dinamičkim pristupom proračunu prolaženja toplote kroz spoljašnji zid tokom zimskog perioda. Analizirana su dva karakteristična slučaja: zid od pune opeke debljine 25 cm i zid od opeke sa dodatnim termoizolacionim slojem debljine 10 cm sa spoljašnje strane. Nestacionarno harmonijsko prolaženje toplote modelirano je numeričkim rešavanjem Furijeove jednačine metodom konačnih razlika, uz potpuno implicitnu vremensku diskretizaciju, primenom simulacija razvijenih u programskom jeziku Python. Dobijeni rezultati pokazuju da stacionarni proračun nije u stanju da opiše razliku između ulaznog i izlaznog toplotnog protoka, niti da kvantifikuje količinu toplote akumulisane u zidu, dok nestacionarni, odnosno dinamički pristup, koji obuhvata vremenske promene temperature spoljašnjeg vazduha i efekte akumulacije toplote u građevinskim elementima, omogućava znatno realniji opis termičkog ponašanja konstrukcije.
- 31 March 2026
- Published by University Library in Kragujevac in Energija Ekonomija Ekologija
- Vol. 28 (1)
Određivnje količine toplote akumulisane u zidu pri nestacionarnim promenama temperature spoljašnjeg vazduh
Iako standard EN ISO 13790:2010 „Energetske performanse zgrada – Proračun energije koja se koristi za grejanje i hlađenje“ definiše tri metode proračuna (kvazi-stacionarni mesečni metod i dva dinamička – jednostavan i detaljan časovni metod), trenutno važeći Pravilnik o energetskoj efikasnosti zgrada (Sl. glasnik RS, br. 61/2011) i dalje propisuje primenu najjednostavnijeg i najnepouzdanijeg kvazi-stacionarnog mesečnog metoda za određivanje godišnje potrebne količine toplote potrebne za grejanje zgrada. Ovaj pristup se zasniva na pretpostavci stacionarnog prolaženja toplote, pri čemu se zanemaruju vremenske promene temperature spoljašnjeg vazduha i efekti akumulacije toplote u građevinskim elementima, što može dovesti do značajnih odstupanja u proceni toplotnih gubitaka. Sa ciljem utvrđivanja greške koja nastaje primenom ova dva pristupa, u radu je izvršeno poređenje vrednosti toplotnih protoka dobijenih stacionarnim i nestacionarnim, odnosno dinamičkim pristupom proračunu prolaženja toplote kroz spoljašnji zid tokom zimskog perioda. Analizirana su dva karakteristična slučaja: zid od pune opeke debljine 25 cm i zid od opeke sa dodatnim termoizolacionim slojem debljine 10 cm sa spoljašnje strane. Nestacionarno harmonijsko prolaženje toplote modelirano je numeričkim rešavanjem Furijeove jednačine metodom konačnih razlika, uz potpuno implicitnu vremensku diskretizaciju, primenom simulacija razvijenih u programskom jeziku Python. Dobijeni rezultati pokazuju da stacionarni proračun nije u stanju da opiše razliku između ulaznog i izlaznog toplotnog protoka, niti da kvantifikuje količinu toplote akumulisane u zidu, dok nestacionarni, odnosno dinamički pristup, koji obuhvata vremenske promene temperature spoljašnjeg vazduha i efekte akumulacije toplote u građevinskim elementima, omogućava znatno realniji opis termičkog ponašanja konstrukcije.
- Open Access
- 1 January 2026
- Published by National Library of Serbia in Thermal Science
- Vol. 30 (1 Part B) , 521-534
Energy and exergy analysis of a hybrid organic cycle power plant
Organic Rankine cycles are highly recommended technology to generate electricity from low temperature sources such as geothermal sources. The performance of the cycle mostly depends on operation conditions, installed equipment and selection of working fluid. This paper presents a comparative energy and exergy analysis of a geothermal-biomass organic Rankine cycle for three working fluids: R113, R245fa, and R600a. In addition, analyzed organic Rankine cycle is compared with the Rankine cycle that runs on Serbian lignite from the aspect of equivalent CO2 emission and necessary primary energy. The analyzed system is an organic Rankine cycle power plant with two heat sources, geothermal water from Vranjska Banja and wood biomass. The results revealed the highest thermal and exergy efficiency with R113, 14.53%, and 41.64%, respectively, as well as the turbine power output of 4.21 MW with 73.20 kW pump power input. Exergy analysis showed the highest exergy destruction rate in the heat exchanger with flue gases made by wood combustion (80%-89%) and the highest obtained exergy efficiency of 41.64% in the case of R113. If the power plant used Serbian lignite as a fuel for the same thermal power input, it would need between 133-169 kt per year of lignite, which would result in CO2 emission of around 63-80 kt per year.
- 1 January 2026
- Published by National Library of Serbia in Thermal Science
- Vol. 30 (1 Part B) , 521-534
Open AccessEnergy and exergy analysis of a hybrid organic cycle power plant
Organic Rankine cycles are highly recommended technology to generate electricity from low temperature sources such as geothermal sources. The performance of the cycle mostly depends on operation conditions, installed equipment and selection of working fluid. This paper presents a comparative energy and exergy analysis of a geothermal-biomass organic Rankine cycle for three working fluids: R113, R245fa, and R600a. In addition, analyzed organic Rankine cycle is compared with the Rankine cycle that runs on Serbian lignite from the aspect of equivalent CO2 emission and necessary primary energy. The analyzed system is an organic Rankine cycle power plant with two heat sources, geothermal water from Vranjska Banja and wood biomass. The results revealed the highest thermal and exergy efficiency with R113, 14.53%, and 41.64%, respectively, as well as the turbine power output of 4.21 MW with 73.20 kW pump power input. Exergy analysis showed the highest exergy destruction rate in the heat exchanger with flue gases made by wood combustion (80%-89%) and the highest obtained exergy efficiency of 41.64% in the case of R113. If the power plant used Serbian lignite as a fuel for the same thermal power input, it would need between 133-169 kt per year of lignite, which would result in CO2 emission of around 63-80 kt per year.
- 5 December 2025
- Published by University Library in Kragujevac in Energija Ekonomija Ekologija
- Vol. 27 (4)
Reduction of Pollutant Emissions and Energy Consumption in Buildings Using Life Cycle Assessment
Life cycle assessment (LCA) is used to evaluate environmental impact and energy consumption of the construction sector. This methodology is a complex process that includes all stages, from the production and transportation of raw materials for building materials, through the construction phase, to the usage and recycling of materials at the end of their lifetime. Since determining any environmental impact is a complex process, software tools designed for conducting LCA, carbon footprint analysis, or other environmental indicator assessments are used, such as: GaBi, SaaS, Open LCA and SimaPro. For the purpose of comparing different construction materials, the paper outlines the procedure for conducting LCA analysis on various construction elements: light straw clay, cob, rammed earth, insulated rammed earth, insulated wooden wall, concrete wall and insulated concrete wall. Additionally, an analysis of the life cycle inventory (LCI) across all stages of production in the cement industry is presented, assuming the use of cement produced in Serbia for the production of concrete walls. The analysis of the obtained results revealed that energy consumption during the production and transportation process is significantly higher than during the raw material extraction phase. The cement production process has the greatest impact on the emission of pollutants that affect human health in concrete walls, due to harmful and hazardous substances released during production, as well as fugitive emissions generated during the transport and processing of raw materials. Life cycle impact assessment (LCIA) during the construction phase of all seven building elements showed that using building elements made from natural materials reduces energy consumption by 30 – 83 %. Pollutant emissions are reduced by 27 - 99 %, while air acidification is reduced by 57 - 98 %. The study showed that transitioning to earth and bio-based construction is a justified strategy for reducing the ecological impact of buildings on the environment. In addition to reducing CO2eq. emissions and energy consumption, the use of these materials also alters the total emissions of pollutants throughout the entire life cycle.
- 5 December 2025
- Published by University Library in Kragujevac in Energija Ekonomija Ekologija
- Vol. 27 (4)
Reduction of Pollutant Emissions and Energy Consumption in Buildings Using Life Cycle Assessment
Life cycle assessment (LCA) is used to evaluate environmental impact and energy consumption of the construction sector. This methodology is a complex process that includes all stages, from the production and transportation of raw materials for building materials, through the construction phase, to the usage and recycling of materials at the end of their lifetime. Since determining any environmental impact is a complex process, software tools designed for conducting LCA, carbon footprint analysis, or other environmental indicator assessments are used, such as: GaBi, SaaS, Open LCA and SimaPro. For the purpose of comparing different construction materials, the paper outlines the procedure for conducting LCA analysis on various construction elements: light straw clay, cob, rammed earth, insulated rammed earth, insulated wooden wall, concrete wall and insulated concrete wall. Additionally, an analysis of the life cycle inventory (LCI) across all stages of production in the cement industry is presented, assuming the use of cement produced in Serbia for the production of concrete walls. The analysis of the obtained results revealed that energy consumption during the production and transportation process is significantly higher than during the raw material extraction phase. The cement production process has the greatest impact on the emission of pollutants that affect human health in concrete walls, due to harmful and hazardous substances released during production, as well as fugitive emissions generated during the transport and processing of raw materials. Life cycle impact assessment (LCIA) during the construction phase of all seven building elements showed that using building elements made from natural materials reduces energy consumption by 30 – 83 %. Pollutant emissions are reduced by 27 - 99 %, while air acidification is reduced by 57 - 98 %. The study showed that transitioning to earth and bio-based construction is a justified strategy for reducing the ecological impact of buildings on the environment. In addition to reducing CO2eq. emissions and energy consumption, the use of these materials also alters the total emissions of pollutants throughout the entire life cycle.
- Open Access
- 9 September 2025
- Published by Faculty of Mechanical Engineering in Strojniški vestnik - Journal of Mechanical Engineering
- Vol. 71 (7-8) , 242-248
Thermodynamic Evaluation and Working Fluid Selection for a Heat Pump Integrated into a Hydropower Plant HVAC System: A Case Study from Serbia
This paper presents a thermodynamic analysis of two types of heat pumps integrated into the heating, ventilation, and air conditioning (HVAC) system of the “Bajina Bašta” hydropower plant located in Serbia. The study aims to replace existing electric boilers with more energy-efficient solutions by utilising renewable heat sources. A comparative evaluation of water source heat pump (WSHP) and air source heat pump (ASHP) configurations was conducted using a custom-developed MATLAB model based on CoolProp data of working fluids. The analysis was supported by real data obtained through in situ measurements of air and water temperatures at the selected location, ensuring accurate input parameters for the simulations. Five refrigerants (R-410A, R-407C, R-134a, R-32, and R-1270) were used, and R-32 was selected as the optimal working fluid because of its high efficiency, moderate flammability, and low environmental impact. The lowest coefficient of performance (COP) for the WSHP was 3.27 in January, while the seasonal coefficient of performance (SCOP) reached 3.36, approximately 15.5 % higher than the ASHP counterpart (SCOP = 2.91). The study confirms that, upon analyzing the entire heating period, WSHP systems are technically and environmentally superior to ASHPs in the locations studied. The proposed configuration, based on real measured data and obtained results, can significantly improve energy efficiency and reduce internal electricity consumption in hydropower plants, thereby supporting the decarbonisation of large-scale renewable energy facilities. While most previous studies have focused on improving energy efficiency in buildings, this work demonstrates the substantial yet underexplored potential for efficiency improvements in the electricity production sector in Serbia. The study specifically examines hydropower plants in Serbia, where heating and air conditioning systems built in the 1960s remain highly energy inefficient. By quantifying the benefits of integrating WSHP and ASHP systems, the research highlights a pathway toward significantly enhancing the energy efficiency of hydropower infrastructures.
- 9 September 2025
- Published by Faculty of Mechanical Engineering in Strojniški vestnik - Journal of Mechanical Engineering
- Vol. 71 (7-8) , 242-248
Open AccessThermodynamic Evaluation and Working Fluid Selection for a Heat Pump Integrated into a Hydropower Plant HVAC System: A Case Study from Serbia
This paper presents a thermodynamic analysis of two types of heat pumps integrated into the heating, ventilation, and air conditioning (HVAC) system of the “Bajina Bašta” hydropower plant located in Serbia. The study aims to replace existing electric boilers with more energy-efficient solutions by utilising renewable heat sources. A comparative evaluation of water source heat pump (WSHP) and air source heat pump (ASHP) configurations was conducted using a custom-developed MATLAB model based on CoolProp data of working fluids. The analysis was supported by real data obtained through in situ measurements of air and water temperatures at the selected location, ensuring accurate input parameters for the simulations. Five refrigerants (R-410A, R-407C, R-134a, R-32, and R-1270) were used, and R-32 was selected as the optimal working fluid because of its high efficiency, moderate flammability, and low environmental impact. The lowest coefficient of performance (COP) for the WSHP was 3.27 in January, while the seasonal coefficient of performance (SCOP) reached 3.36, approximately 15.5 % higher than the ASHP counterpart (SCOP = 2.91). The study confirms that, upon analyzing the entire heating period, WSHP systems are technically and environmentally superior to ASHPs in the locations studied. The proposed configuration, based on real measured data and obtained results, can significantly improve energy efficiency and reduce internal electricity consumption in hydropower plants, thereby supporting the decarbonisation of large-scale renewable energy facilities. While most previous studies have focused on improving energy efficiency in buildings, this work demonstrates the substantial yet underexplored potential for efficiency improvements in the electricity production sector in Serbia. The study specifically examines hydropower plants in Serbia, where heating and air conditioning systems built in the 1960s remain highly energy inefficient. By quantifying the benefits of integrating WSHP and ASHP systems, the research highlights a pathway toward significantly enhancing the energy efficiency of hydropower infrastructures.
- 1 January 2025
- Published by University Library in Kragujevac in Energija Ekonomija Ekologija
- Vol. XXVII (3) , 21-29
Calculation of Annual Energy Consumption of a Heat Pump by the Bin-method
Heat pumps are electrical devices that transfer thermal energy from the environment into a heated space. Thanks to their ability, compared to electric resistance heaters, to deliver three to six times more thermal energy to the conditioned space, heat pumps represent an unrivaled solution in heating technology in terms of efficiency. When the thermal energy source is outdoor air — as in the case of air-to-air heat pumps — their efficiency directly depends on the temperature of the outdoor air. Therefore, the assessment of the total energy consumption of a heat pump must be based on a methodology that takes into account the variation of this temperature. According to Standard EN 15316, two methods are defined for determining the total energy consumption of a heat pump: the degree-day method and the temperature-bin method. In domestic practice, only the simpler and less accurate degree-day method is used. The temperature-bin method, although more reliable, has remained almost unknown, probably due to the need for hourly outdoor air temperature data. To present and bring this method closer to engineering practice, the paper describes the theoretical background and outlines the main steps of the method, while its application is demonstrated through a case study of the EPS AD office building in Bajina Bašta. By grouping actual hourly outdoor air temperature data into temperature bins and linking them with the operating points of the heat pump, while including the operation of auxiliary equipment and backup heaters, the total annual electricity consumption was determined. The obtained consumption of 56,150 kWh of electricity — of which 86% occurs in the heating and 14% in the cooling mode — clearly indicates the dominant influence of winter hours on total energy use.
- 1 January 2025
- Published by University Library in Kragujevac in Energija Ekonomija Ekologija
- Vol. XXVII (3) , 21-29
Calculation of Annual Energy Consumption of a Heat Pump by the Bin-method
Heat pumps are electrical devices that transfer thermal energy from the environment into a heated space. Thanks to their ability, compared to electric resistance heaters, to deliver three to six times more thermal energy to the conditioned space, heat pumps represent an unrivaled solution in heating technology in terms of efficiency. When the thermal energy source is outdoor air — as in the case of air-to-air heat pumps — their efficiency directly depends on the temperature of the outdoor air. Therefore, the assessment of the total energy consumption of a heat pump must be based on a methodology that takes into account the variation of this temperature. According to Standard EN 15316, two methods are defined for determining the total energy consumption of a heat pump: the degree-day method and the temperature-bin method. In domestic practice, only the simpler and less accurate degree-day method is used. The temperature-bin method, although more reliable, has remained almost unknown, probably due to the need for hourly outdoor air temperature data. To present and bring this method closer to engineering practice, the paper describes the theoretical background and outlines the main steps of the method, while its application is demonstrated through a case study of the EPS AD office building in Bajina Bašta. By grouping actual hourly outdoor air temperature data into temperature bins and linking them with the operating points of the heat pump, while including the operation of auxiliary equipment and backup heaters, the total annual electricity consumption was determined. The obtained consumption of 56,150 kWh of electricity — of which 86% occurs in the heating and 14% in the cooling mode — clearly indicates the dominant influence of winter hours on total energy use.
- 1 January 2024
- Published by University Library in Kragujevac in Energija Ekonomija Ekologija
- Vol. XXVI (1) , 34-41
Determination of energy performance of building according to ISO 52016-1
With the idea of harmonizing with current EU regulation regarding methodology used for energy certification of buildings, and with aim of achieving energy savings in the building sector, the dynamic hourly calculation methodology for determining energy needs of the building for heating and cooling was presented and analyzed. The presented method is based on the new, currently valid standard SRPS EN ISO 52016-1. Unlike the previous so-called three-node method, determined by the now extracted standard SRPS EN ISO 13790, this method does not group layers of the construction envelope, but treats separately each layer of each element of the construction envelope. Accordingly, the new calculation method is based on forming energy balance equations not only for the internal and external boundary surface, but also for each layer of the building element, and their coupled solution for boundary conditions that change on an hourly basis. Due to complexity of this methodology, which in addition to the hourly temperatures of the external air, hourly values of solar irradiance, radiation to the sky, but also the own radiation of all solid surfaces, also takes into account dynamic behavior of all elements of the building's thermal envelope (resistance to heat conduction and heat accumulation of each layer of the envelope), a special software was developed, verification of which, as well as verification of methodology, was performed on the example of determining energy needs of a model object for heating and cooling.
- 1 January 2024
- Published by University Library in Kragujevac in Energija Ekonomija Ekologija
- Vol. XXVI (1) , 34-41
Determination of energy performance of building according to ISO 52016-1
With the idea of harmonizing with current EU regulation regarding methodology used for energy certification of buildings, and with aim of achieving energy savings in the building sector, the dynamic hourly calculation methodology for determining energy needs of the building for heating and cooling was presented and analyzed. The presented method is based on the new, currently valid standard SRPS EN ISO 52016-1. Unlike the previous so-called three-node method, determined by the now extracted standard SRPS EN ISO 13790, this method does not group layers of the construction envelope, but treats separately each layer of each element of the construction envelope. Accordingly, the new calculation method is based on forming energy balance equations not only for the internal and external boundary surface, but also for each layer of the building element, and their coupled solution for boundary conditions that change on an hourly basis. Due to complexity of this methodology, which in addition to the hourly temperatures of the external air, hourly values of solar irradiance, radiation to the sky, but also the own radiation of all solid surfaces, also takes into account dynamic behavior of all elements of the building's thermal envelope (resistance to heat conduction and heat accumulation of each layer of the envelope), a special software was developed, verification of which, as well as verification of methodology, was performed on the example of determining energy needs of a model object for heating and cooling.
- Open Access
- 1 January 2024
- Published by Centre for Evaluation in Education and Science (CEON/CEES)
- No. vol. 20, i,p. 132-141
An overview on optimal modeling of hybrid renewable energy systems for enhancing energy management strategies
To meet the growing demand for electricity generation, the use of renewable energy sources represents an ideal alternative to traditional resources. Compared to individual systems utilizing renewable energy sources, hybrid renewable energy systems (HRES) for electricity generation combine renewable energy sources and/or fossil fuels, providing more reliable electricity supply while achieving environmental and economic sustainability. It is crucial to optimally model all components of hybrid energy systems to meet overall electricity demands with minimal investment and operational costs. This paper provides an overview of currently available commercial software for optimizing hybrid renewable energy systems, with a specific focus on the software Homer (Hybrid Optimization of Multiple Electric Renewables). Approaches and phases of the optimization process for these systems are presented, as well as key parameters that must be considered during analysis.
- 1 January 2024
- Published by Centre for Evaluation in Education and Science (CEON/CEES)
- No. vol. 20, i,p. 132-141
Open AccessAn overview on optimal modeling of hybrid renewable energy systems for enhancing energy management strategies
To meet the growing demand for electricity generation, the use of renewable energy sources represents an ideal alternative to traditional resources. Compared to individual systems utilizing renewable energy sources, hybrid renewable energy systems (HRES) for electricity generation combine renewable energy sources and/or fossil fuels, providing more reliable electricity supply while achieving environmental and economic sustainability. It is crucial to optimally model all components of hybrid energy systems to meet overall electricity demands with minimal investment and operational costs. This paper provides an overview of currently available commercial software for optimizing hybrid renewable energy systems, with a specific focus on the software Homer (Hybrid Optimization of Multiple Electric Renewables). Approaches and phases of the optimization process for these systems are presented, as well as key parameters that must be considered during analysis.
- Open Access
- 1 January 2024
- Published by National Library of Serbia in Thermal Science
- Vol. 28 (1 Part B) , 425-435
Thermal recovery test for determining the thermal conductivity of the soil
This paper presents a new in-situ experimental procedure for determining a thermal conductivity of soil, as one of the thermophysical properties necessary for dimensioning vertical buried heat exchangers of geothermal heat pumps. The proposed method, called the thermal recovery test, is based on the assumption that there is a direct analogy between the hydrodynamic process of filling (recovery) the well with water from a porous aquifer after its partial or complete discharging and the process of establishment of thermal equilibrium in an infinite medium previously disturbed by a line heat sink (source). Apart from presentation the theoretical background of these two phenomena, the display of the identical theoretical logarithmic character of the change of hydrostatic pressure and soil temperature, description of the experimental procedure, the experimental results of three performed experiments are also presented. Additionally, results for the experimentally obtained values of the thermal conductivity of the soil are compared with those obtained from the thermal response test, and the advantages and drawbacks of the new thermal recovery test method are analyzed.
- 1 January 2024
- Published by National Library of Serbia in Thermal Science
- Vol. 28 (1 Part B) , 425-435
Open AccessThermal recovery test for determining the thermal conductivity of the soil
This paper presents a new in-situ experimental procedure for determining a thermal conductivity of soil, as one of the thermophysical properties necessary for dimensioning vertical buried heat exchangers of geothermal heat pumps. The proposed method, called the thermal recovery test, is based on the assumption that there is a direct analogy between the hydrodynamic process of filling (recovery) the well with water from a porous aquifer after its partial or complete discharging and the process of establishment of thermal equilibrium in an infinite medium previously disturbed by a line heat sink (source). Apart from presentation the theoretical background of these two phenomena, the display of the identical theoretical logarithmic character of the change of hydrostatic pressure and soil temperature, description of the experimental procedure, the experimental results of three performed experiments are also presented. Additionally, results for the experimentally obtained values of the thermal conductivity of the soil are compared with those obtained from the thermal response test, and the advantages and drawbacks of the new thermal recovery test method are analyzed.