Adnan Zafar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Adnan Zafar has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Ahmed Kamal Siddiqi
Division of Cardiothoracic Imaging, Department of Radiology and Imaging Sciences, Emory University, Atlanta, GA, United States
1 shared publication - Ahmed Mustafa Rashid
Baylor Scott and White Research Institute, Baylor Scott and White Health, Dallas, Texas
1 shared publication - Arsalan Zafar Iqbal
Department of Medicine, FMH Lahore Medical College, Lahore, Pakistan
1 shared publication - Jagpal Singh Klair
Digestive Disease Institute, Virginia Mason Medical Center, Seattle, WA, USA
1 shared publication - Rajesh Krishnamoorthi
Division of Gastroenterology and Hepatology, Center for Digestive Health, Virginia Mason Franciscan Health, Seattle, WA 98101, USA
1 shared publication - Syed Sarmad Javaid
Department of Medicine, University of Mississippi Medical Center, Jackson, MS
1 shared publication
Latest Publications
- Open Access
- 30 July 2023
- Published by The Korean Society of Gastrointestinal Endoscopy in Clinical Endoscopy
- Vol. 56 (4) , 446-452
Use of abdominal compression device in colonoscopy: a systematic review and meta-analysis
Background/Aims: Colonoscopy for screening is associated with unpleasant experiences for patients, and abdominal compression devices have been developed to minimize these problems. However, there is a paucity of data supporting the therapeutic benefits of this strategy. This study examined the effects of using an abdominal compression device during colonoscopy on the cecal intubation time (CIT), abdominal compression, patient comfort, and postural changes.Methods: We searched PubMed and Scopus (from inception to November 2021) for randomized controlled trials that assessed the effects of an abdominal compression device during colonoscopy on CIT, abdominal compression, patient comfort, and postural change. A random-effects meta-analysis was performed. Weighted mean differences (WMDs) and Mantel-Haenszel odds ratios (ORs) were calculated.Results: Our pooled analysis of seven randomized controlled trials revealed that abdominal compression devices significantly reduced CIT (WMD, –0.76 [–1.49 to –0.03] minutes; p=0.04), abdominal compression (OR, 0.52; 95% confidence interval [CI], 0.28–0.94; p=0.03), and postural changes (OR, 0.46; 95% CI, 0.27–0.78; p=0.004) during colonoscopy. However, our results did not show a significant change in patient comfort (WMD, –0.48; 95% CI, –1.05 to 0.08; p=0.09) when using an abdominal compression device.Conclusions: Our findings demonstrate that employing an abdominal compression device may reduce CIT, abdominal compression, and postural change but have no impact on patient comfort.
- 30 July 2023
- Published by The Korean Society of Gastrointestinal Endoscopy in Clinical Endoscopy
- Vol. 56 (4) , 446-452
Open AccessUse of abdominal compression device in colonoscopy: a systematic review and meta-analysis
Background/Aims: Colonoscopy for screening is associated with unpleasant experiences for patients, and abdominal compression devices have been developed to minimize these problems. However, there is a paucity of data supporting the therapeutic benefits of this strategy. This study examined the effects of using an abdominal compression device during colonoscopy on the cecal intubation time (CIT), abdominal compression, patient comfort, and postural changes.Methods: We searched PubMed and Scopus (from inception to November 2021) for randomized controlled trials that assessed the effects of an abdominal compression device during colonoscopy on CIT, abdominal compression, patient comfort, and postural change. A random-effects meta-analysis was performed. Weighted mean differences (WMDs) and Mantel-Haenszel odds ratios (ORs) were calculated.Results: Our pooled analysis of seven randomized controlled trials revealed that abdominal compression devices significantly reduced CIT (WMD, –0.76 [–1.49 to –0.03] minutes; p=0.04), abdominal compression (OR, 0.52; 95% confidence interval [CI], 0.28–0.94; p=0.03), and postural changes (OR, 0.46; 95% CI, 0.27–0.78; p=0.004) during colonoscopy. However, our results did not show a significant change in patient comfort (WMD, –0.48; 95% CI, –1.05 to 0.08; p=0.09) when using an abdominal compression device.Conclusions: Our findings demonstrate that employing an abdominal compression device may reduce CIT, abdominal compression, and postural change but have no impact on patient comfort.