James D. Johnston
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
James D. Johnston has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- David R. Wilson
Department of Orthopaedics, University of British Columbia, Vancouver, Canada
3 shared publications Christine E. McLennan
Division of Research, New England Baptist Hospital, Boston, MA, USA
2 shared publicationsDavid J. Hunter
Institute of Bone and Joint Research, Kolling Institute, University of Sydney and Rheumatology Department, Royal North Shore Hospital, Sydney, NSW, Australia
2 shared publicationsHanieh Arjmand
Department of Mechanical Engineering, University of Saskatchewan, Saskatoon, SK, Canada
2 shared publicationsMajid Nazemi
Department of Mechanical Engineering, University of Saskatchewan, Saskatoon, SK, Canada
2 shared publicationsSaija A. Kontulainen
College of Kinesiology, University of Saskatchewan, Saskatoon, SK, Canada
2 shared publications
Latest Publications
- Open Access
- 2 May 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 7053
Author Correction: Mechanical Metrics of the Proximal Tibia are Precise and Differentiate Osteoarthritic and Normal Knees: A Finite Element Study
A correction to this article has been published and is linked from the HTML and PDF versions of this paper. The error has not been fixed in the paper.
- 2 May 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 7053
Open AccessAuthor Correction: Mechanical Metrics of the Proximal Tibia are Precise and Differentiate Osteoarthritic and Normal Knees: A Finite Element Study
A correction to this article has been published and is linked from the HTML and PDF versions of this paper. The error has not been fixed in the paper.
- Open Access
- 31 July 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 11478
Mechanical Metrics of the Proximal Tibia are Precise and Differentiate Osteoarthritic and Normal Knees: A Finite Element Study
Our objective was to identify precise mechanical metrics of the proximal tibia which differentiated OA and normal knees. We developed subject-specific FE models for 14 participants (7 OA, 7 normal) who were imaged three times each for assessing precision (repeatability). We assessed various mechanical metrics (minimum principal and von Mises stress and strain as well as structural stiffness) across the proximal tibia for each subject. In vivo precision of these mechanical metrics was assessed using CV%RMS. We performed parametric and non-parametric statistical analyses and determined Cohen’s d effect sizes to explore differences between OA and normal knees. For all FE-based mechanical metrics, average CV%RMS was less than 6%. Minimum principal stress was, on average, 75% higher in OA versus normal knees while minimum principal strain values did not differ. No difference was observed in structural stiffness. FE modeling could precisely quantify and differentiate mechanical metrics variations in normal and OA knees, in vivo. This study suggests that bone stress patterns may be important for understanding OA pathogenesis at the knee.
- 31 July 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 11478
Open AccessMechanical Metrics of the Proximal Tibia are Precise and Differentiate Osteoarthritic and Normal Knees: A Finite Element Study
Our objective was to identify precise mechanical metrics of the proximal tibia which differentiated OA and normal knees. We developed subject-specific FE models for 14 participants (7 OA, 7 normal) who were imaged three times each for assessing precision (repeatability). We assessed various mechanical metrics (minimum principal and von Mises stress and strain as well as structural stiffness) across the proximal tibia for each subject. In vivo precision of these mechanical metrics was assessed using CV%RMS. We performed parametric and non-parametric statistical analyses and determined Cohen’s d effect sizes to explore differences between OA and normal knees. For all FE-based mechanical metrics, average CV%RMS was less than 6%. Minimum principal stress was, on average, 75% higher in OA versus normal knees while minimum principal strain values did not differ. No difference was observed in structural stiffness. FE modeling could precisely quantify and differentiate mechanical metrics variations in normal and OA knees, in vivo. This study suggests that bone stress patterns may be important for understanding OA pathogenesis at the knee.
- 1 September 2015
- Published by Elsevier in Osteoarthritis and Cartilage
- Vol. 23 (9) , 1483-1490
Knee osteoarthritis patients with severe nocturnal pain have altered proximal tibial subchondral bone mineral density
- 1 September 2015
- Published by Elsevier in Osteoarthritis and Cartilage
- Vol. 23 (9) , 1483-1490
Knee osteoarthritis patients with severe nocturnal pain have altered proximal tibial subchondral bone mineral density
- 24 August 2015
- Published by Elsevier in Journal of Biomechanics
- Vol. 48 (13) , 3672-3678
From the rhombic transposition flap toward Z-plasty: An optimized design using the finite element method
- 24 August 2015
- Published by Elsevier in Journal of Biomechanics
- Vol. 48 (13) , 3672-3678
From the rhombic transposition flap toward Z-plasty: An optimized design using the finite element method
- 30 April 2014
- Published by Springer Nature in Osteoporosis International
- Vol. 25 (8) , 2057-2066
Characterizing microarchitectural changes at the distal radius and tibia in postmenopausal women using HR-pQCT
Limited prospective evidence exists regarding bone microarchitectural deterioration. We report annual changes in trabecular and cortical bone microarchitecture at the distal radius and tibia in postmenopausal women. Lost trabeculae with corresponding increase in trabecular thickness at the radius and thinning tibial cortex indicated trabecularization of the cortex at both sites. Osteoporosis is characterized by low bone mass and the deterioration of bone microarchitecture. However, limited prospective evidence exists regarding bone microarchitectural changes in postmenopausal women: a population prone to sustaining osteoporotic fractures. Our primary objective was to characterize the annual change in bone area, density, and microarchitecture at the distal radius and distal tibia in postmenopausal women. Distal radius and tibia were measured using high-resolution peripheral quantitative computed tomography (HR-pQCT) at baseline and 1 year later in 51 women (mean age ± SD, 77 ± 7 years) randomly sampled from the Saskatoon cohort of the Canadian Multicentre Osteoporosis Study (CaMos). We used repeated measures analysis of variance (ANOVA) with Bonferroni adjustment for multiple comparisons to characterize the mean annual change in total density, cortical perimeter, trabecular and cortical bone area, density, content, and microarchitecture. Significant changes were accepted at P < 0.05. At the distal radius in women without bone-altering drugs, total density (−1.7 %) and trabecular number (−6.4 %) decreased, while trabecular thickness (+6.0 %), separation (+8.6 %), and heterogeneity (+12.1 %) increased. At their distal tibia, cortical area (−4.5 %), density (−1.9 %), content (−6.3 %), and thickness (−4.4 %) decreased, while trabecular area (+0.4 %) increased. The observed loss of trabeculae with concomitant increase in trabecular size at the distal radius and the declined cortical thickness, density, and content at the distal tibia indicated a site-specific trabecularization of the cortical bone in postmenopausal women.
- 30 April 2014
- Published by Springer Nature in Osteoporosis International
- Vol. 25 (8) , 2057-2066
Characterizing microarchitectural changes at the distal radius and tibia in postmenopausal women using HR-pQCT
Limited prospective evidence exists regarding bone microarchitectural deterioration. We report annual changes in trabecular and cortical bone microarchitecture at the distal radius and tibia in postmenopausal women. Lost trabeculae with corresponding increase in trabecular thickness at the radius and thinning tibial cortex indicated trabecularization of the cortex at both sites. Osteoporosis is characterized by low bone mass and the deterioration of bone microarchitecture. However, limited prospective evidence exists regarding bone microarchitectural changes in postmenopausal women: a population prone to sustaining osteoporotic fractures. Our primary objective was to characterize the annual change in bone area, density, and microarchitecture at the distal radius and distal tibia in postmenopausal women. Distal radius and tibia were measured using high-resolution peripheral quantitative computed tomography (HR-pQCT) at baseline and 1 year later in 51 women (mean age ± SD, 77 ± 7 years) randomly sampled from the Saskatoon cohort of the Canadian Multicentre Osteoporosis Study (CaMos). We used repeated measures analysis of variance (ANOVA) with Bonferroni adjustment for multiple comparisons to characterize the mean annual change in total density, cortical perimeter, trabecular and cortical bone area, density, content, and microarchitecture. Significant changes were accepted at P < 0.05. At the distal radius in women without bone-altering drugs, total density (−1.7 %) and trabecular number (−6.4 %) decreased, while trabecular thickness (+6.0 %), separation (+8.6 %), and heterogeneity (+12.1 %) increased. At their distal tibia, cortical area (−4.5 %), density (−1.9 %), content (−6.3 %), and thickness (−4.4 %) decreased, while trabecular area (+0.4 %) increased. The observed loss of trabeculae with concomitant increase in trabecular size at the distal radius and the declined cortical thickness, density, and content at the distal tibia indicated a site-specific trabecularization of the cortical bone in postmenopausal women.