RVR. Di Vora

R. Di Vora

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


R. Di Vora has a total of 64 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Search for Postinflationary QCD Axions with a Quantum-Limited Tunable Microwave Receiver

    by G. Sardo Infirri, D. Alesini, C. Braggio, G. Cappelli, G. Carugno, D. D’aGostino, A. D’eLia, D. Di Gioacchino, R. Di Vora, M. Esposito, et al.

    A search for cosmological axions has been performed by scanning a frequency region of 38 MHz centered at about 10.2 GHz, corresponding to an axion mass m a ≃ 42 μ eV . The QUAX experimental apparatus, a haloscope comprised of a 1-liter volume tunable cavity immersed in an 8 T magnetic field and a quantum-limited detection chain, set limits on the axion-photon coupling at the 10 − 14 GeV − 1 level. As no signal candidate has been observed, viable hadronic axion models are ruled out in a currently preferred postinflationary region m a > 40 μ eV .


  • A tunable dielectric-loaded copper resonator for axion searches at 11 GHz

    by R. Di Vora, A. Gardikiotis, C. Braggio, G. Carugno, A. Lombardi, A. Ortolan, G. Ruoso

    In the context of axion searches with haloscopes, tunable cavity resonators with high quality factor and high effective volume at frequencies above about 8 GHz are central for probing the axion–photon coupling with the required sensitivity to reach the quantum chromodynamics axion models. Higher order modes in dielectric-loaded cavities allow for higher effective volumes and larger quality factors compared to basic cylindrical cavities, but a proper cavity frequency tuning mechanism to probe broad axion mass ranges is not yet available. In this work, we report about the design and construction of a tunable prototype of a single-shell dielectric-boosted resonator with its axion-sensitive pseudo-TM030 high-order mode at about 11 GHz frequency. A clamshell tuning method previously tested for empty cylindrical resonators has been perfected for this geometry through simulations and in situ tests conducted at cryogenic temperature. Tuning is accomplished in a range of about 2% of the central frequency, without significantly impacting the unloaded quality factor of about 175 000. The experimental results presented in this work demonstrate the tunability of this type of resonator, definitely confirming its applicability to high frequency axion searches.


  • Top Cited Papers
    Open Access

    Quantum-Enhanced Sensing of Axion Dark Matter with a Transmon-Based Single Microwave Photon Counter

    by C. Braggio, L. Balembois, R. Di Vora, Z. Wang, J. Travesedo, L. Pallegoix, G. Carugno, A. Ortolan, G. Ruoso, U. Gambardella, et al.

    We report an axion dark matter search with a haloscope equipped with a microwave photon counter. The haloscope is a tunable high quality factor three-dimensional microwave cavity placed in a magnetic field. The photon counter, operated cyclically, maps an incoming microwave photon onto the state of a superconducting transmon qubit. The measurement protocol continuously monitors the power emitted by the haloscope cavity as well as the dark count background and enables tuning of the cavity frequency to probe different axion masses. With this apparatus, we enhance by a factor of 20 the search speed that can be reached with quantum-limited linear amplifiers and set a new standard for probing the existence of axions with resonant detectors above 5 GHz.


  • Axion haloscope resonators: The polygonal coaxial cavity

    by R. Di Vora, A. Lombardi, A. Ortolan, G. Ruoso, C. Braggio, G. Carugno, A. Gardikiotis


  • Open Access

    A tunable dielectric resonator for axion searches at 11 GHz

    by R. Di Vora, A. Gardikiotis, C. Braggio, G. Carugno, A. Lombardi, A. Ortolan, G. Ruoso

    In the context of axion search with haloscopes, tunable cavity resonators with high quality factor and high effective volume at frequencies above about 8 GHz are central for probing the axion-photon coupling with the required sensitivity to reach the QCD axion models. Higher order modes in dielectrically-loaded cavities allow for higher effective volumes and larger quality factors compared to basic cylindrical cavities, but a proper cavity frequency tuning mechanism to probe broad axion mass ranges is yet not available. In this work, we report about the design and construction of a tunable prototype of a single-shell dielectric resonator with its axion-sensitive pseudo-TM$_{030}$ high-order mode at about 11 GHz frequency. A clamshell tuning method previously tested for empty cylindrical resonators has been perfected for this geometry through simulations and in situ tests conducted at cryogenic temperature. Tuning is accomplished in a range of about 2 $\%$ the central frequency, without significantly impacting the quality factor of about 175000. The experimental results presented in this work demonstrate the tunability of this type of resonator, definitely confirming its applicability to high frequency axion searches.

  • Open Access

    A tunable clamshell cavity for wavelike dark matter searches

    by C. Braggio, G. Carugno, R. Di Vora, A. Ortolan, G. Ruoso, D. Seyler

    Here, we present a frequency tuning mechanism for microwave cavities designed for axion dark matter searches and show that it provides a range of at least 200 MHz for the fundamental mode TM010 resonant at ∼10 GHz. The apparatus is based on a clamshell cavity, with the two semi-cells held together at a fixed joint while the other side opens to tune the frequency of the resonant modes. Measurements of the cavity frequencies and quality factor were taken at liquid helium temperature as the aperture was increased incrementally to ∼2°. We show that the frequency shift is approximately linear with respect to the angle of aperture with no mode crossings present for an aperture less than 2°. Furthermore, the form factor and quality factor of the TM010 mode remain relatively constant throughout the tuning as predicted by simulation.


  • Open Access

    Search for Galactic axions with a high- Q dielectric cavity

    by D. Alesini, D. Babusci, C. Braggio, G. Carugno, N. Crescini, D. D’aGostino, A. D’eLia, D. Di Gioacchino, R. Di Vora, P. Falferi, et al.

    A haloscope of the QUAX–aγ experiment, composed of an high-Q resonant cavity immersed in a 8 T magnet and cooled to ∼4.5  K is operated to search for galactic axions with mass ma≃42.8  μeV, not accessible to other running experiments. The design of the cavity with hollow dielectric cylinders concentrically inserted in a OFHC Cu cavity, allowed us to maintain a loaded quality-factor Q∼300000 during the measurements in presence of magnetic field. Through the cavity tuning mechanism it was possible to modulate the resonance frequency of the haloscope in the region 10.35337−10.35345  GHz and thus acquire different datasets at different resonance frequencies. Acquiring each datasets for about 50 minutes, combining them and correcting for the axion’s signal estimation-efficiency, we set a limit on the axion-photon coupling gaγγ<0.731×10−13  GeV−1 with the confidence level set at 90%.


  • High- Q Microwave Dielectric Resonator for Axion Dark-Matter Haloscopes

    by R. Di Vora, D. Alesini, C. Braggio, G. Carugno, N. Crescini, D. D’aGostino, D. Di Gioacchino, P. Falferi, U. Gambardella, C. Gatti, et al.

    The frequency band 1–15 GHz provides exciting prospects for resonant axion haloscopes as indicated by cosmological and astrophysical arguments. Among the challenges currently addressed to reach the required sensitivity, the development of high-quality factor cavities that tolerate multitesla fields plays a central role. We report a three-dimensional resonator based on a right-circular copper cavity with hollow cylinders that confine higher-order modes around the cylinder axis. Its effective volume at 10.3 GHz is 3.4×10−2 l, and under an 8-T field we measure an internal quality factor of more than nine million. A fine-tuning system limited to approximately 1-MHz range is tested, useful for understanding the conditions required to run a haloscope with a cavity exceeding the axion quality factor. The cavity parameters we report demonstrate the potential of this unique resonator to probe galactic dark-matter axion at scan rates exceeding 2 MHz/day when the cavity is readout by a quantum-limited receiver.


  • Open Access

    Search for invisible axion dark matter of mass m$_a=43~μ$eV with the QUAX--$aγ$ experiment

    by D. Alesini, C. Braggio, G. Carugno, N. Crescini, D. D'Agostino, D. Di Gioacchino, R. Di Vora, P. Falferi, U. Gambardella, C. Gatti, et al.

    A haloscope of the QUAX--$a\gamma$ experiment composed of an oxygen-free high thermal conductivity-Cu cavity inside an 8.1 T magnet and cooled to $\sim200$ mK is put in operation for the search of galactic axion with mass $m_a\simeq43~\mu\text{eV}$. The power emitted by the resonant cavity is amplified with a Josephson parametric amplifier whose noise fluctuations are at the standard quantum limit. With the data collected in about 1 h at the cavity frequency $\nu_c=10.40176$ GHz, the experiment reaches the sensitivity necessary for the detection of galactic QCD-axion, setting the $90\%$ confidence level limit to the axion-photon coupling $g_{a\gamma\gamma}<0.639\times10^{-13}$ GeV$^{-1}$.

  • Open Access

    Search for invisible axion dark matter of mass ma=43  μeV with the QUAX– aγ experiment

    by D. Alesini, C. Braggio, G. Carugno, N. Crescini, D. D’aGostino, D. Di Gioacchino, R. Di Vora, P. Falferi, U. Gambardella, C. Gatti, et al.

    A haloscope of the QUAX–aγ experiment composed of an oxygen-free high thermal conductivity-Cu cavity inside an 8.1 T magnet and cooled to ∼200  mK is put in operation for the search of galactic axion with mass ma≃43  μeV. The power emitted by the resonant cavity is amplified with a Josephson parametric amplifier whose noise fluctuations are at the standard quantum limit. With the data collected in about 1 h at the cavity frequency νc=10.40176  GHz, the experiment reaches the sensitivity necessary for the detection of galactic QCD-axion, setting the 90% confidence level limit to the axion-photon coupling gaγγ<0.766×10−13  GeV−1.