Le Thi Minh Tam
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Le Thi Minh Tam has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Nguyen Thi Huyen Trang
HCMC University of Technology, VNU-HCM
2 shared publications - Nguyen Thi Huyen Trang
Faculty of Environment and Natural Resources, Ho Chi Minh City University of Technology, VNU- HCM, Vietnam
2 shared publications - Truong Ngoc Viet
Faculty of Environment and Natural Resources, Ho Chi Minh City University of Technology, VNU- HCM, Vietnam
2 shared publications - Dinh Quoc Tuc
Faculty of Environment and Natural Resources, Ho Chi Minh City University of Technology - VNU- HCM, Vietnam
1 shared publication Luan Thanh Nguyen
Faculty of Environment and Natural Resources, Ho Chi Minh City University of Technology, VNU- HCM, Vietnam
1 shared publicationNguyen Truong An
CARE, Ho Chi Minh City University of Technology - VNU-HCM, Vietnam
1 shared publication
Latest Publications
- Open Access
- 15 April 2019
- Published by Viet Nam National University Ho Chi Minh City in Journal of Science and Technology Development
- Vol. 20 (K9) , 45-52
Effect of oxygen states in horizontal subsurface flow constructed wetlands on the removal of organic matter, nutrients, some metals and octylphenol
Constructed wetland is a low cost, effective technology and it is still in the state of improvement to enhance the treatment efficiency, especially in nutrient and trace elements treatment. This study investigated the effect of aerobic and anoxic conditions in Horizontal Subsurface Flow Constructed Wetland (HSFCW) on nutrient, organic, metal and Octylphenol - OP (Endocrine disrupting chemical) treatment. Two HSFCWs were constructed: HSFCW1 with three aerobic compartments; HSFCW2 with two aerobic compartments, one anoxic compartment. The two HSFCWs had the same design parameters (fiters, plants), except oxygen conditions. The results showed that aerobic and anoxic HSFCW may increase the efficiency of Nitrogen removal by 10%, but decreased by 11% in the efficiency of OP treatment (one of the EDCs). The efficiency of treatment of pollutants, including NH4+-N, COD, TP, Mn, Fe, Al and Cu between two HSFCWs were not significantly different; the average efficiency was 99%, 84%, 97%, 96%, 96%, 72% and 73%, respectively. Therefore, the anoxic compartment of HSFCW still provided the effective removal of organic matter, Manuscript received September 29th, 2017; accepted 24th December, 2017 This study was funded by CARE RESCIF under grant number Tc-TTC-2017-05. An Truong Nguyen, Tam Minh Thi Le, Viet Quoc Tran, Trang Huyen Thi Nguyen are with the CARE, Ho Chi Minh City University of Technology, VNU-HCM, Vietnam (truongan.hcmut@gmail.com, minhtamnt2006@hcmut.edu.vn, ngthtrang@hcmut.edu.vn) Viet Ngoc Truong, Luan Thanh Nguyen, Phi Hoang Tan Nguyen are with the Faculty of Environment and Natural Resources, Ho Chi Minh City University of Technology, VNU- HCM, Vietnam (truongngocviet93@gmail.com) metals and octylphenol, but it also improved nitrogen removal efficiency by up to 92%.
- 15 April 2019
- Published by Viet Nam National University Ho Chi Minh City in Journal of Science and Technology Development
- Vol. 20 (K9) , 45-52
Open AccessEffect of oxygen states in horizontal subsurface flow constructed wetlands on the removal of organic matter, nutrients, some metals and octylphenol
Constructed wetland is a low cost, effective technology and it is still in the state of improvement to enhance the treatment efficiency, especially in nutrient and trace elements treatment. This study investigated the effect of aerobic and anoxic conditions in Horizontal Subsurface Flow Constructed Wetland (HSFCW) on nutrient, organic, metal and Octylphenol - OP (Endocrine disrupting chemical) treatment. Two HSFCWs were constructed: HSFCW1 with three aerobic compartments; HSFCW2 with two aerobic compartments, one anoxic compartment. The two HSFCWs had the same design parameters (fiters, plants), except oxygen conditions. The results showed that aerobic and anoxic HSFCW may increase the efficiency of Nitrogen removal by 10%, but decreased by 11% in the efficiency of OP treatment (one of the EDCs). The efficiency of treatment of pollutants, including NH4+-N, COD, TP, Mn, Fe, Al and Cu between two HSFCWs were not significantly different; the average efficiency was 99%, 84%, 97%, 96%, 96%, 72% and 73%, respectively. Therefore, the anoxic compartment of HSFCW still provided the effective removal of organic matter, Manuscript received September 29th, 2017; accepted 24th December, 2017 This study was funded by CARE RESCIF under grant number Tc-TTC-2017-05. An Truong Nguyen, Tam Minh Thi Le, Viet Quoc Tran, Trang Huyen Thi Nguyen are with the CARE, Ho Chi Minh City University of Technology, VNU-HCM, Vietnam (truongan.hcmut@gmail.com, minhtamnt2006@hcmut.edu.vn, ngthtrang@hcmut.edu.vn) Viet Ngoc Truong, Luan Thanh Nguyen, Phi Hoang Tan Nguyen are with the Faculty of Environment and Natural Resources, Ho Chi Minh City University of Technology, VNU- HCM, Vietnam (truongngocviet93@gmail.com) metals and octylphenol, but it also improved nitrogen removal efficiency by up to 92%.
- Open Access
- 13 April 2019
- Published by Viet Nam National University Ho Chi Minh City in Journal of Science and Technology Development
- Vol. 20 (K8) , 42-49
Recommendation of optimal design and operation parameters for constructed wetland for sludge treatment based on the effect of hydraulic retention time, sludge loading rate and vegetation
Industrial sludge is a by-product which is enormously generated in wastewater treatment plants. Constructed wetland for sludge treatment (CWST) is a low cost, effective technology. This study investigated the effect of various design and operation parameters on the efficiency of four pilot-scale CWSTs to determine the optimal parameters by using the Analytic Hierarchy Process (AHP) for Decision- Making. The wetland units were planted with Phragmites australis or Typha angustifolia, operated with four sludge loading rate (SLR) (50, 60, 70 and 80 L/m2) and monitored in six different hydraulic retention time (HRT) (2,5,7,9,12 and 14 days). AHP results provided the optimal key parameters (vegetation of P. australis, 14-day HRT, SLR of 60 L/m2) which gave the most effective sludge treatment, reducing 99.8%, 95.16% and 98.23% for COD, TKN and TP, respectively. The results also showed that HRT, SLR and vegetation remarkably affected to the efficiency of CWST. In addition, AHP is an effective method to determine the optimal design and operation parameters of CWST.
- 13 April 2019
- Published by Viet Nam National University Ho Chi Minh City in Journal of Science and Technology Development
- Vol. 20 (K8) , 42-49
Open AccessRecommendation of optimal design and operation parameters for constructed wetland for sludge treatment based on the effect of hydraulic retention time, sludge loading rate and vegetation
Industrial sludge is a by-product which is enormously generated in wastewater treatment plants. Constructed wetland for sludge treatment (CWST) is a low cost, effective technology. This study investigated the effect of various design and operation parameters on the efficiency of four pilot-scale CWSTs to determine the optimal parameters by using the Analytic Hierarchy Process (AHP) for Decision- Making. The wetland units were planted with Phragmites australis or Typha angustifolia, operated with four sludge loading rate (SLR) (50, 60, 70 and 80 L/m2) and monitored in six different hydraulic retention time (HRT) (2,5,7,9,12 and 14 days). AHP results provided the optimal key parameters (vegetation of P. australis, 14-day HRT, SLR of 60 L/m2) which gave the most effective sludge treatment, reducing 99.8%, 95.16% and 98.23% for COD, TKN and TP, respectively. The results also showed that HRT, SLR and vegetation remarkably affected to the efficiency of CWST. In addition, AHP is an effective method to determine the optimal design and operation parameters of CWST.