Abu Z. Saeed
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Abu Z. Saeed has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Shahbaz Shafi Malik
Worcestershire Acute Hospitals NHS Trust Worcester UK
3 shared publications - Usman Ahmed
Worcestershire Acute Hospitals NHS Trust, Worcester, UK
3 shared publications - Peter D'ALessandro
Orthopaedic Research Foundation of Western Australia, Medical School, Discipline of Surgery University of Western Australia Claremont Australia
2 shared publications - Randeep S. Aujla
University Hospitals of Leicester Leicester UK
2 shared publications - Tahir Khaleeq
The Robert Jones and Agnes Hunt Orthopaedic Hospital, Oswestry, UK
2 shared publications - Tarek Boutefnouchet
University Hospitals of Birmingham NHS Foundation Trust, Birmingham Knee School Birmingham UK
2 shared publications
Latest Publications
- 15 December 2025
- Published by Springer Nature in Journal of Robotic Surgery
- Vol. 20 (1) , 87
Do image-based robotic TKR systems improve radiological or clinical outcomes compared to image-free systems? A systematic review and meta-analysis
Robotic total knee replacement (TKR) systems improve the precision of implant positioning. They can either be image-based(IB) or image-free(IF), and each has a different pre-operative imaging requirement and workflow. The primary aim of this systematic review and meta-analysis is to compare the differences in post-operative radiographic alignment and implant position between IB and IF systems. The secondary aim is to compare patient-reported outcome measures(PROMs) and complications between IB and IF systems. A systematic review and meta-analysis were conducted in accordance with PRISMA guidelines. Studies reporting on implant position, radiological alignment, clinical outcomes or complications between IB and IF robotic knee systems were included. The studies were assessed using the Methodical Index for Non-Randomised Studies (MINORS) tool. Five studies fulfilled the inclusion criteria. There was no significant difference in outlier rates between IB and IF systems for femoral coronal alignment 6.8% vs. 2.6% [OR 2.00, (95% CI 0.81 to 4.96)], tibial coronal alignment 3.4% vs. 2.1% [OR 1.49, (95% CI 0.57 to 3.89)], posterior tibial slope 23.5% vs. 4.4% [OR 2.90, (95% CI 0.11 to 73.49)], HKA 4.8% vs. 2.5% [OR 1.38, (95% CI 0.19 to 9.81)] between the two groups. There was no significant difference in complication rate between IB and IF groups, 7.6% vs. 3.0% [OR 2.53, (95% CI 0.86 to 7.42)]. No studies reported improved PROMs between IB and IF robotic TKR systems. The mean MINORS score for comparative studies was 16.8 (Range 15–19). This meta-analysis did not find evidence of any improvement in radiological, clinical or PROMs outcomes in IB systems compared to IF systems. Further randomised controlled trials are required to assess the superiority of either system as the current evidence base is small with heterogenous measurement methodologies.
- 15 December 2025
- Published by Springer Nature in Journal of Robotic Surgery
- Vol. 20 (1) , 87
Do image-based robotic TKR systems improve radiological or clinical outcomes compared to image-free systems? A systematic review and meta-analysis
Robotic total knee replacement (TKR) systems improve the precision of implant positioning. They can either be image-based(IB) or image-free(IF), and each has a different pre-operative imaging requirement and workflow. The primary aim of this systematic review and meta-analysis is to compare the differences in post-operative radiographic alignment and implant position between IB and IF systems. The secondary aim is to compare patient-reported outcome measures(PROMs) and complications between IB and IF systems. A systematic review and meta-analysis were conducted in accordance with PRISMA guidelines. Studies reporting on implant position, radiological alignment, clinical outcomes or complications between IB and IF robotic knee systems were included. The studies were assessed using the Methodical Index for Non-Randomised Studies (MINORS) tool. Five studies fulfilled the inclusion criteria. There was no significant difference in outlier rates between IB and IF systems for femoral coronal alignment 6.8% vs. 2.6% [OR 2.00, (95% CI 0.81 to 4.96)], tibial coronal alignment 3.4% vs. 2.1% [OR 1.49, (95% CI 0.57 to 3.89)], posterior tibial slope 23.5% vs. 4.4% [OR 2.90, (95% CI 0.11 to 73.49)], HKA 4.8% vs. 2.5% [OR 1.38, (95% CI 0.19 to 9.81)] between the two groups. There was no significant difference in complication rate between IB and IF groups, 7.6% vs. 3.0% [OR 2.53, (95% CI 0.86 to 7.42)]. No studies reported improved PROMs between IB and IF robotic TKR systems. The mean MINORS score for comparative studies was 16.8 (Range 15–19). This meta-analysis did not find evidence of any improvement in radiological, clinical or PROMs outcomes in IB systems compared to IF systems. Further randomised controlled trials are required to assess the superiority of either system as the current evidence base is small with heterogenous measurement methodologies.
- Open Access
- 6 January 2024
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 144 (3) , 1331
Correction to: No clinical advantage with customized individually made implants over conventional off-the-shelf implants in total knee arthroplasty: a systematic review and meta-analysis
- 6 January 2024
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 144 (3) , 1331
Open AccessCorrection to: No clinical advantage with customized individually made implants over conventional off-the-shelf implants in total knee arthroplasty: a systematic review and meta-analysis
- 18 November 2023
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 144 (3) , 1311-1330
No clinical advantage with customized individually made implants over conventional off-the-shelf implants in total knee arthroplasty: a systematic review and meta-analysis
Introduction Total knee arthroplasty (TKA) can be performed with either conventional off-the-shelf (OTS) or customized individually-made (CIM) implants. The evidence for CIM implants is limited and variable, and the aim of this review was to compare clinical and radiological outcomes between CIM and OTS implants. Methods A systematic review and meta-analysis were conducted in accordance with PRISMA guidelines. Studies reporting on clinical, radiological, or alignment outcomes for CIM and OTS implants were selected. The studies were appraised using the Methodical index for non-randomized studies tool. Results Twenty-three studies fulfilled the inclusion criteria. The studies comprised 2856 CIM and 1877 OTS TKAs. Revision rate was higher with CIM (5.9%) compared to OTS (3.7%) implants [OR 1.23(95% CI 0.69–2.18)]. Manipulation under anesthesia (MUA) was higher in CIM (2.2%) compared to OTS (1.1%) group [OR 2.95(95% CI 0.95–9.13)] and complications rate was higher in CIM (5%) vs. OTS (4.5%) [OR 1.45(95% CI 0.53–3.96)] but neither reached statistical significance. Length of stay was significantly shorter in CIM group 2.9 days vs. 3.5 days [MD − 0.51(95% CI − 0.82 to − 0.20)]. Knee Society Score showed no difference between CIM and OTS groups for Knee 90.5 vs. 90.6 [MD − 0.27(95% CI − 4.27 to 3.73)] and Function 86.1 vs. 83.1 [MD 1.51(95% CI − 3.69 to 6.70)]. Conclusion CIM implants in TKA have theoretical benefits over OTS prostheses. However, in this present review, CIM implants were associated with higher revisions, MUA, and overall complication rates. There was no difference in outcome score and CIM implants did not improve overall target alignment; however, more CIM TKAs were found to be in the HKA target zone compared to OTS TKAs. The findings of this review do not support the general utilization of CIM over OTS implants in TKA.
- 18 November 2023
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 144 (3) , 1311-1330
No clinical advantage with customized individually made implants over conventional off-the-shelf implants in total knee arthroplasty: a systematic review and meta-analysis
Introduction Total knee arthroplasty (TKA) can be performed with either conventional off-the-shelf (OTS) or customized individually-made (CIM) implants. The evidence for CIM implants is limited and variable, and the aim of this review was to compare clinical and radiological outcomes between CIM and OTS implants. Methods A systematic review and meta-analysis were conducted in accordance with PRISMA guidelines. Studies reporting on clinical, radiological, or alignment outcomes for CIM and OTS implants were selected. The studies were appraised using the Methodical index for non-randomized studies tool. Results Twenty-three studies fulfilled the inclusion criteria. The studies comprised 2856 CIM and 1877 OTS TKAs. Revision rate was higher with CIM (5.9%) compared to OTS (3.7%) implants [OR 1.23(95% CI 0.69–2.18)]. Manipulation under anesthesia (MUA) was higher in CIM (2.2%) compared to OTS (1.1%) group [OR 2.95(95% CI 0.95–9.13)] and complications rate was higher in CIM (5%) vs. OTS (4.5%) [OR 1.45(95% CI 0.53–3.96)] but neither reached statistical significance. Length of stay was significantly shorter in CIM group 2.9 days vs. 3.5 days [MD − 0.51(95% CI − 0.82 to − 0.20)]. Knee Society Score showed no difference between CIM and OTS groups for Knee 90.5 vs. 90.6 [MD − 0.27(95% CI − 4.27 to 3.73)] and Function 86.1 vs. 83.1 [MD 1.51(95% CI − 3.69 to 6.70)]. Conclusion CIM implants in TKA have theoretical benefits over OTS prostheses. However, in this present review, CIM implants were associated with higher revisions, MUA, and overall complication rates. There was no difference in outcome score and CIM implants did not improve overall target alignment; however, more CIM TKAs were found to be in the HKA target zone compared to OTS TKAs. The findings of this review do not support the general utilization of CIM over OTS implants in TKA.
- 28 September 2022
- Published by Elsevier in Orthopaedics & Traumatology: Surgery & Research
- Vol. 109 (4) , 103424
Open and arthroscopic posterior bone block with iliac crest autograft for posterior shoulder instability – systematic review of clinical and radiological outcomes
- 28 September 2022
- Published by Elsevier in Orthopaedics & Traumatology: Surgery & Research
- Vol. 109 (4) , 103424
Open and arthroscopic posterior bone block with iliac crest autograft for posterior shoulder instability – systematic review of clinical and radiological outcomes