LSLin Su

Lin Su

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Lin Su has a total of 5 co-authors. Here are the top co-authors by number of shared publications:

  • Kaijun Dong

    Guangzhou Institute of Energy Conversion, Chinese Academy of Sciences, Guangzhou 510640, China

    2 shared publications
  • Jing Li

    State Grid Hubei Electric Power Research Institute, Wuhan 430077, China

    1 shared publication
  • Yaokang Zhang

    Guangzhou Institute of Energy Conversion, Chinese Academy of Sciences, Guangzhou 510640, China

    1 shared publication
  • Zhaoyang Xu

    NARI Group Corporation/State Grid Electric Power Research Institute, Nanjing 210000, China

    1 shared publication
  • Zhilin Huang

    Chinese Academy of Sciences, Guangzhou Institute of Energy Conversion, Guangzhou 510640, China

    1 shared publication

Latest Publications

  • Experimental Thermal Study of Ice Slurry Production System Equipped With Direct Contact Heat Exchanger and Spiral Nozzle

    by Yaokang Zhang, Lin Su, Zhaoyang Xu, Kaijun Dong, Jing Li

    For the direct contact ice slurry production system, the obstacles of ice blockage in the nozzle, enormous refrigerant charge, and refrigerant-water separation restrict its commercial application. In this paper, a novel direct contact ice slurry production system is proposed to overcome these obstacles. In this novel system, the horizontal PVC pipe with the spiral nozzle is designed as a direct contact ice slurry generator to avoid ice blockage in the nozzle. The two-phase RC318 is utilized as the system refrigerant. In order to investigate the ice production performance of this novel system, the effects of compressor rotational speed, internal water flowrate, and initial system pressure on ice production performance are experimentally studied, and a lump model is established. The results show that the ice production performance is mainly affected by the compressor rotational speed, but scarcely affected by the internal water flowrate. However, large ice blocks are formed at small internal water flowrate. Besides, the lump model is considered to be able to predict the water temperature. Furthermore, the sinking of the liquid refrigerant exits under the higher initial system pressure, but it can be avoided by reducing the initial system pressure.


  • Thermal Environment Analysis and Improvement on Isolated Cold Aisle Data Centers

    by Lin Su, Zhilin Huang, Kaijun Dong

    Isolated cold aisle airflow distribution is a transitional form from non-isolated airflow distribution to closed cold aisle airflow distribution. With the increase of the power of racks, cooling failure may happen in the layout of the isolated cold aisle. This paper presents the study on cooling performance of the racks which are improved through bottom ventilating reform and adjustment. Inlet/outlet air temperature and mass flow rate of the racks are investigated in detail under conditions of various bottom ventilated areas and various porosities of the raised floor. The characteristics of airflow distribution are contrastively analyzed through calculating indexes of the thermal environment of data centers. Results show that adequate ventilation through the bottom of the racks is good for improvement of the state of airflow distribution. There is an optimization range (0.1–0.3 m and 0.05–0.15 m, respectively) of the ventilated area at the bottom of the racks. And high porosity (above 50%) of the ventilated area can reduce the inlet and outlet temperatures of the racks and the racks in different positions have a better temperature uniformity. In conclusion, bottom ventilation of racks is a feasible plan to improve airflow distribution, and schemes of ventilated area and porosity of corresponding raised floor should be designed respectively under consideration of the layout of racks and AC.