Fadly Achmad
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Fadly Achmad has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Ahmad Rifqi Asrib
Universitas Negeri Makassar
1 shared publication - Ahmad Rifqi Asrib
Universitas Negeri Makassar
1 shared publication - Husain Syam
Universitas Negeri Makassar
1 shared publication - Husain Syam
Universitas Negeri Makassar
1 shared publication
Latest Publications
- Open Access
- 3 September 2024
- Published by Fakultas Teknik, Universitas Negeri Makassar in Jurnal Vokasi Keteknikan
- Vol. 2 (2) , 77-82
EFFECTIVENESS OF THE FLOOD EDUCATION MODEL IN GORONTALO CITY
In mitigating the flood disasters that often hit Gorontalo City, the participation of all parties is needed, starting from the local government, campus and community. Disaster education at the community level must be used as an initial lesson in disaster mitigation. One effort that can be made is by mapping land types in Gorontalo City which is then disseminated to technical agencies (PUPR) in order to reduce the risk of flooding in vulnerable areas. The research began with technical mapping of soil types in flood areas in Gorontalo City. Maps were analyzed using GIS applications. The resulting GIS map was then submitted to the Gorontalo City PUPR Service. The research results show that the dominant clay soil is spread across 6 sub-districts in Gorontalo City, namely Kota Selatan, Kota Tengah, Kota Utara, Kota Timur, Dungingi and Sipatana Districts. Some of them are in Kota Barat and Dumbo Raya sub-districts. Meanwhile, in Hulonthalangi District, sandy soil is more dominated; the educational model regarding technical maps of soil types received a positive response from the Gorontalo City PUPR Service.
- 3 September 2024
- Published by Fakultas Teknik, Universitas Negeri Makassar in Jurnal Vokasi Keteknikan
- Vol. 2 (2) , 77-82
Open AccessEFFECTIVENESS OF THE FLOOD EDUCATION MODEL IN GORONTALO CITY
In mitigating the flood disasters that often hit Gorontalo City, the participation of all parties is needed, starting from the local government, campus and community. Disaster education at the community level must be used as an initial lesson in disaster mitigation. One effort that can be made is by mapping land types in Gorontalo City which is then disseminated to technical agencies (PUPR) in order to reduce the risk of flooding in vulnerable areas. The research began with technical mapping of soil types in flood areas in Gorontalo City. Maps were analyzed using GIS applications. The resulting GIS map was then submitted to the Gorontalo City PUPR Service. The research results show that the dominant clay soil is spread across 6 sub-districts in Gorontalo City, namely Kota Selatan, Kota Tengah, Kota Utara, Kota Timur, Dungingi and Sipatana Districts. Some of them are in Kota Barat and Dumbo Raya sub-districts. Meanwhile, in Hulonthalangi District, sandy soil is more dominated; the educational model regarding technical maps of soil types received a positive response from the Gorontalo City PUPR Service.
- 28 July 2023
- Published by Sciencedomain International in Asian Journal of Education and Social Studies
- Vol. 48 (1) , 104-110
Public Response of Ipilo Village to the Flood Education Model in Gorontalo City
- 28 July 2023
- Published by Sciencedomain International in Asian Journal of Education and Social Studies
- Vol. 48 (1) , 104-110
Public Response of Ipilo Village to the Flood Education Model in Gorontalo City
- Open Access
- 1 March 2021
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 1098 (2) , 022030
Comparison of laboratory test and in-situ test results against bored pile foundation bearing capacity at Sido Mukti II Bridge Foundation Gorontalo Province
The purpose of this study is to compare the bearing capacity of the bored pile from the results of laboratory tests and in situ tests. Soil investigations conducted in the field in the form of a Standard Penetration Test (SPT), and drilling. SPT test to obtain variations in soil density. While drilling is used to describe the soil profile at a certain depth. The research method is in the form of analysis of bearing capacity based on comparison of the results of in-situ tests and laboratory tests. Soil results from drilling are taken in 2 conditions namely disturbed conditions to describe each layer and undisturbed samples to be tested in a laboratory with a direct shear test or unconfined compressive strength. Based on the comparison of the value of the allowable bearing capacity is found that the analysis of the results of the in-situ test gives a value of the allowable bearing capacity more than the laboratory tests. This is due to the soil condition in the field at the testing experiencing compaction due to blow SPT.
- 1 March 2021
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 1098 (2) , 022030
Open AccessComparison of laboratory test and in-situ test results against bored pile foundation bearing capacity at Sido Mukti II Bridge Foundation Gorontalo Province
The purpose of this study is to compare the bearing capacity of the bored pile from the results of laboratory tests and in situ tests. Soil investigations conducted in the field in the form of a Standard Penetration Test (SPT), and drilling. SPT test to obtain variations in soil density. While drilling is used to describe the soil profile at a certain depth. The research method is in the form of analysis of bearing capacity based on comparison of the results of in-situ tests and laboratory tests. Soil results from drilling are taken in 2 conditions namely disturbed conditions to describe each layer and undisturbed samples to be tested in a laboratory with a direct shear test or unconfined compressive strength. Based on the comparison of the value of the allowable bearing capacity is found that the analysis of the results of the in-situ test gives a value of the allowable bearing capacity more than the laboratory tests. This is due to the soil condition in the field at the testing experiencing compaction due to blow SPT.