ASAlexander Schmitz

Alexander Schmitz

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Alexander Schmitz has a total of 5 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Convenient self-calibrating full-Stokes imaging polarimeter and its application to particle synthesis in reactive plasmas

    by Alexander Schmitz, Andreas Petersen, Franko Greiner

    Imaging polarimetry is becoming an increasingly significant tool, from remote sensing to material characterization. In reactive plasmas, polarimetry is a well-established diagnostic for the size and the complex refractive index of synthesized particles. We present the StokesCam, a self-calibrating, full-Stokes imaging polarimeter based on two micropolarizer cameras. It employs an adapted eigenvalue calibration to address the problem of spatial inhomogeneities and artifacts in polarization optics. A comprehensive uncertainty analysis is provided, using a bootstrapping and Monte Carlo technique to quantify the systematic and statistical errors. The application of the StokesCam to a particle growth process in a reactive plasma is demonstrated as an example of demanding measurement conditions. The device provides high-quality data for scattering modeling and enables not only the spatial monitoring of particle growth but also allows for future studies of the system’s asymmetric multiscattering. This work also serves as a practical guide for readers interested in constructing and deploying their own full-Stokes imaging polarimeter.


  • Open Access

    A neural network approach to kinetic Mie polarimetry for particle size diagnostics in nanodusty plasmas

    by Alexander Schmitz, Andreas Petersen, Franko Greiner

    The analysis of the size of nanoparticles is an essential task in plasma technology and dusty plasmas. Light scattering techniques, based on Mie theory, can be used as a non-invasive and in-situ diagnostic tool for this purpose. However, the standard back-calculation methods require expertise from the user. To address this, we introduce a neural network that performs the same task. We discuss how we set up and trained the network to analyze the size of plasma-grown amorphous carbon nanoparticles (a:C-H) with a refractive index n in the range of real(n) = 1.4-2.2 and imag(n) = 0.04i-0.1i and a radius of up to several hundred nanometers, depending on the used wavelength. The diagnostic approach is kinetic, which means that the particles need to change in size due to growth or etching. An uncertainty analysis as well as a test with experimental data are presented. Our neural network achieves results that agree with those of prior fitting algorithms while offering higher methodical stability. The model also holds a major advantage in terms of computing speed and automation.

  • A neural network approach to kinetic Mie polarimetry for particle size diagnostics in nanodusty plasmas

    by Alexander Schmitz, Andreas Petersen, Franko Greiner

    The analysis of the size of nanoparticles is an essential task in plasma technology and dusty plasmas. Light scattering techniques, based on Mie theory, can be used as a non-invasive and in-situ diagnostic tool for this purpose. However, the standard back-calculation methods require expertise from the user. To address this, we introduce a neural network that performs the same task. We discuss how we set up and trained the network to analyze the size of plasma-grown amorphous carbon nanoparticles (a:C–H) with a refractive index n in the range of real(n) = 1.4 − 2.2 and imag(n) = 0.04 i − 0.1 i and a radius of up to several hundred nanometers, depending on the used wavelength. The diagnostic approach is kinetic, which means that the particles need to change in size due to growth or etching. An uncertainty analysis as well as a test with experimental data are presented. Our neural network achieves results that agree with those of prior fitting algorithms while offering higher methodical stability. The model also holds a major advantage in terms of computing speed and automation.


  • Open Access

    Video aided extinction measurement: A competitive method for dust density diagnostics

    by Andreas Petersen, Julia Kobus, Alexander Schmitz, Sebastian Wolf, Franko Greiner

    Among the most popular methods to measure dust density in a laboratory setup are 1D extinction, Abel inversion for circularly symmetric geometries, and computer tomography (CT) for arbitrary geometries. We present a new method based on a 1D extinction measurement in correlation with a video taken at an acute angle. It works well with limited optical access and has a good time resolution (at least several hertz). It measures the dust density within a slice of a nanodust cloud with precision comparable to other methods. Depending on the setup, this video aided extinction measurement can replace CT.