Felix Wetzler
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Felix Wetzler has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Monika Saumer
2 shared publicationsGuido Falk
1 shared publication- Hans-Georg Herrmann
Core Facility for Correlative Microscopy and Tomography CoMiTo Faculty of Natural Sciences and Technology Saarland University Saarbruecken Germany
1 shared publication Jan-Erik Nebel
1 shared publicationJanina Koziol
1 shared publication- Jonas Fell
Core Facility for Correlative Microscopy and Tomography CoMiTo Faculty of Natural Sciences and Technology Saarland University Saarbruecken Germany
1 shared publication
Latest Publications
- Open Access
- 18 January 2026
- Published by Elsevier in Journal of Materials Research and Technology
- Vol. 41, 1754-1764
Nanoporous aluminum oxide templates to tailor magnetic anisotropy of electrodeposited cobalt phosphorus nanowires for hard magnetic micro devices
- 18 January 2026
- Published by Elsevier in Journal of Materials Research and Technology
- Vol. 41, 1754-1764
Open AccessNanoporous aluminum oxide templates to tailor magnetic anisotropy of electrodeposited cobalt phosphorus nanowires for hard magnetic micro devices
- Open Access
- 19 September 2024
- Published by Elsevier in Journal of Materials Research and Technology
- Vol. 33, 2081-2092
Electrochemical deposition of cobalt phosphorus for hard magnetic micro devices and the impact on magnetic anisotropy
- 19 September 2024
- Published by Elsevier in Journal of Materials Research and Technology
- Vol. 33, 2081-2092
Open AccessElectrochemical deposition of cobalt phosphorus for hard magnetic micro devices and the impact on magnetic anisotropy
- Open Access
- 4 August 2023
- Published by MDPI AG in Journal of Imaging
- Vol. 9 (8) , 157
Target Design in SEM-Based Nano-CT and Its Influence on X-ray Imaging
Nano-computed tomography (nano-CT) based on scanning electron microscopy (SEM) is utilized for multimodal material characterization in one instrument. Since SEM-based CT uses geometrical magnification, X-ray targets can be adapted without any further changes to the system. This allows for designing targets with varying geometry and chemical composition to influence the X-ray focal spot, intensity and energy distribution with the aim to enhance the image quality. In this paper, three different target geometries with a varying volume are presented: bulk, foil and needle target. Based on the analyzed electron beam properties and X-ray beam path, the influence of the different target designs on X-ray imaging is investigated. With the obtained information, three targets for different applications are recommended. A platinum (Pt) bulk target tilted by 25° as an optimal combination of high photon flux and spatial resolution is used for fast CT scans and the investigation of high-absorbing or large sample volumes. To image low-absorbing materials, e.g., polymers or organic materials, a target material with a characteristic line energy right above the detector energy threshold is recommended. In the case of the observed system, we used a 30° tilted chromium (Cr) target, leading to a higher image contrast. To reach a maximum spatial resolution of about 100 nm, we recommend a tungsten (W) needle target with a tip diameter of about 100 nm.
- 4 August 2023
- Published by MDPI AG in Journal of Imaging
- Vol. 9 (8) , 157
Open AccessTarget Design in SEM-Based Nano-CT and Its Influence on X-ray Imaging
Nano-computed tomography (nano-CT) based on scanning electron microscopy (SEM) is utilized for multimodal material characterization in one instrument. Since SEM-based CT uses geometrical magnification, X-ray targets can be adapted without any further changes to the system. This allows for designing targets with varying geometry and chemical composition to influence the X-ray focal spot, intensity and energy distribution with the aim to enhance the image quality. In this paper, three different target geometries with a varying volume are presented: bulk, foil and needle target. Based on the analyzed electron beam properties and X-ray beam path, the influence of the different target designs on X-ray imaging is investigated. With the obtained information, three targets for different applications are recommended. A platinum (Pt) bulk target tilted by 25° as an optimal combination of high photon flux and spatial resolution is used for fast CT scans and the investigation of high-absorbing or large sample volumes. To image low-absorbing materials, e.g., polymers or organic materials, a target material with a characteristic line energy right above the detector energy threshold is recommended. In the case of the observed system, we used a 30° tilted chromium (Cr) target, leading to a higher image contrast. To reach a maximum spatial resolution of about 100 nm, we recommend a tungsten (W) needle target with a tip diameter of about 100 nm.