Desheng Jia
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Desheng Jia has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
Hongguang Pan
Department of Otolaryngology—Head and Neck Surgery, Shenzhen Children’s Hospital, Guangdong, China
3 shared publicationsJing Chen
Department of Otolaryngology—Head and Neck Surgery, Shenzhen Children’s Hospital, Guangdong, China
3 shared publications- Shang Yan
Department of Otolaryngology, Shenzhen Children’s Hospital, Shenzhen, Guangdong, China
3 shared publications - Shixiong Chen
School of Medicine, The Chinese University of Hong Kong, Shenzhen, China
3 shared publications - Yong-Chao Chen
Department of Otorhinolaryngology, Shenzhen Children’s Hospital, Shenzhen, China
3 shared publications Chunrui Zhao
Department of Otolaryngology, Shenzhen Childrens Hospital, Shenzhen, China
2 shared publications
Latest Publications
- Open Access
- 10 April 2026
- Published by SAGE Publications in Ear, Nose & Throat Journal
Embedded AI-Assisted Otoscopic Image Screening for Pediatric Otitis Media
Objective: To evaluate an embedded artificial intelligence (AI) system for otoscopic image-based screening and prediagnostic triage of pediatric otitis media, with an emphasis on point-of-care deployment on a microcontroller. Methods: We retrospectively analyzed 19 522 tympanic membrane images labeled by otolaryngologists as acute otitis media, otitis media with effusion, or normal. A lightweight convolutional neural network derived from AlexNet was trained using a patient-level split. Two posttraining INT8 variants (per-channel and per-tensor quantization) were deployed on an STM32H7S78-DK board using STM32Cube.AI. We evaluated accuracy on a held-out test set (n=600) and measured activation memory, total random access memory (RAM) usage, and average inference latency on the target device. Results: The full-precision model achieved 97.67% test accuracy. Per-channel INT8 preserved accuracy (97.67%). Per-tensor INT8 showed a small decrease (97.50%) but reduced activation memory by 16%, total RAM by 8%, and latency by 13%. Conclusion: On-device otoscopic image analysis is feasible on an STM32H7-class microcontroller and may support screening and triage workflows (eg, repeat examination, tympanometry, monitoring, or referral). The tool is not intended to provide a final diagnosis or to direct treatment decisions; clinical diagnosis and management remain clinician-led.
- 10 April 2026
- Published by SAGE Publications in Ear, Nose & Throat Journal
Open AccessEmbedded AI-Assisted Otoscopic Image Screening for Pediatric Otitis Media
Objective: To evaluate an embedded artificial intelligence (AI) system for otoscopic image-based screening and prediagnostic triage of pediatric otitis media, with an emphasis on point-of-care deployment on a microcontroller. Methods: We retrospectively analyzed 19 522 tympanic membrane images labeled by otolaryngologists as acute otitis media, otitis media with effusion, or normal. A lightweight convolutional neural network derived from AlexNet was trained using a patient-level split. Two posttraining INT8 variants (per-channel and per-tensor quantization) were deployed on an STM32H7S78-DK board using STM32Cube.AI. We evaluated accuracy on a held-out test set (n=600) and measured activation memory, total random access memory (RAM) usage, and average inference latency on the target device. Results: The full-precision model achieved 97.67% test accuracy. Per-channel INT8 preserved accuracy (97.67%). Per-tensor INT8 showed a small decrease (97.50%) but reduced activation memory by 16%, total RAM by 8%, and latency by 13%. Conclusion: On-device otoscopic image analysis is feasible on an STM32H7-class microcontroller and may support screening and triage workflows (eg, repeat examination, tympanometry, monitoring, or referral). The tool is not intended to provide a final diagnosis or to direct treatment decisions; clinical diagnosis and management remain clinician-led.
- 1 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 30 (3) , 2127-2138
FIGNet: A Robust and Interpretable Fuzzy-Irreversible Gated Network for Auditory Brainstem Response Classification
Auditory brainstem response (ABR) is an important tool for newborn hearing screening and neurological assessment. However, its signals are often difficult to be accurately resolved due to noise interference and weak waveforms, and the need for repeated measurements under multiple sound intensity conditions results in time-consuming data acquisition. Therefore, there is an urgent need to develop an automatic classification model with high accuracy, robustness and good interpretability to achieve stable and effective recognition performance with minimal ABR data. This study presents FIGNet, a new deep learning model that combines type-2 fuzzy logic with a time-irreversible attention mechanism to address uncertainty and temporal direction in ABR signals. Fuzzy attention helps reduce the impact of noise, while the irreversible attention models the one-way nature of neural responses. Experiments on real ABR datasets show that FIGNet outperforms existing models in both binary and five-class classification tasks. It achieves 93.72% accuracy in binary classification and 84.42% accuracy in five-class classification. Visualization results-including confusion matrices, and accuracy curves under different noise levels-further confirm that FIGNet can focus on key waveform areas and stay reliable even in noisy conditions. These findings demonstrate that FIGNet offers fast, interpretable, and robust performance for clinical ABR analysis, achieving high classification accuracy under both clean and noisy conditions.
- 1 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 30 (3) , 2127-2138
FIGNet: A Robust and Interpretable Fuzzy-Irreversible Gated Network for Auditory Brainstem Response Classification
Auditory brainstem response (ABR) is an important tool for newborn hearing screening and neurological assessment. However, its signals are often difficult to be accurately resolved due to noise interference and weak waveforms, and the need for repeated measurements under multiple sound intensity conditions results in time-consuming data acquisition. Therefore, there is an urgent need to develop an automatic classification model with high accuracy, robustness and good interpretability to achieve stable and effective recognition performance with minimal ABR data. This study presents FIGNet, a new deep learning model that combines type-2 fuzzy logic with a time-irreversible attention mechanism to address uncertainty and temporal direction in ABR signals. Fuzzy attention helps reduce the impact of noise, while the irreversible attention models the one-way nature of neural responses. Experiments on real ABR datasets show that FIGNet outperforms existing models in both binary and five-class classification tasks. It achieves 93.72% accuracy in binary classification and 84.42% accuracy in five-class classification. Visualization results-including confusion matrices, and accuracy curves under different noise levels-further confirm that FIGNet can focus on key waveform areas and stay reliable even in noisy conditions. These findings demonstrate that FIGNet offers fast, interpretable, and robust performance for clinical ABR analysis, achieving high classification accuracy under both clean and noisy conditions.
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 34, 4228-4238
WPTNet-WPL: A Wave-Prior Transformer With Wasserstein Prior Learning for Interpretable Auditory Brainstem Response Assessment
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 34, 4228-4238
Open AccessWPTNet-WPL: A Wave-Prior Transformer With Wasserstein Prior Learning for Interpretable Auditory Brainstem Response Assessment
- Open Access
- 13 September 2025
- Published by SAGE Publications in Ear, Nose & Throat Journal
Construction and Implementation of Otolaryngology Endoscopic Training Based on Artificial Intelligence
Objective: To investigate the effect of artificial intelligence (AI) in the otolaryngology standardized resident training of endoscopy. Methods: A total of 30 standardized training residents from the Department of Otolaryngology at Shenzhen Children’s Hospital were selected from January 2022 to December 2024 and were randomly divided into an experimental group and a control group. They underwent a 1 month endoscopic rotation. The control group received traditional lectures and endoscopic operation training. The experimental group, in addition to the conventional teaching methods, participants can confirm the diagnosis of common pediatric otolaryngology conditions through automatic diagnosis of AI model. The theoretical scores, practical skills assessments, and residents’ satisfaction ratings of both groups were compared. Results: The theoretical and practical scores of the experimental group were significantly higher than those of the control group ( P < .05). Satisfaction rate with training in the experimental group was also significantly higher than that of the control group ( P < .05). The experimental group demonstrated significantly-higher satisfaction levels than the control group in learning interest, learning efficiency, self-directed learning ability, endoscopic theoretical knowledge, endoscopic operational skills, and standardized endoscopic diagnostic reporting ( P < .05). Conclusions: Compared with traditional teaching methods, AI-assisted endoscopy training system can help improve participant satisfaction and skills. More intelligent otolaryngology training models will be developed in the future.
- 13 September 2025
- Published by SAGE Publications in Ear, Nose & Throat Journal
Open AccessConstruction and Implementation of Otolaryngology Endoscopic Training Based on Artificial Intelligence
Objective: To investigate the effect of artificial intelligence (AI) in the otolaryngology standardized resident training of endoscopy. Methods: A total of 30 standardized training residents from the Department of Otolaryngology at Shenzhen Children’s Hospital were selected from January 2022 to December 2024 and were randomly divided into an experimental group and a control group. They underwent a 1 month endoscopic rotation. The control group received traditional lectures and endoscopic operation training. The experimental group, in addition to the conventional teaching methods, participants can confirm the diagnosis of common pediatric otolaryngology conditions through automatic diagnosis of AI model. The theoretical scores, practical skills assessments, and residents’ satisfaction ratings of both groups were compared. Results: The theoretical and practical scores of the experimental group were significantly higher than those of the control group ( P < .05). Satisfaction rate with training in the experimental group was also significantly higher than that of the control group ( P < .05). The experimental group demonstrated significantly-higher satisfaction levels than the control group in learning interest, learning efficiency, self-directed learning ability, endoscopic theoretical knowledge, endoscopic operational skills, and standardized endoscopic diagnostic reporting ( P < .05). Conclusions: Compared with traditional teaching methods, AI-assisted endoscopy training system can help improve participant satisfaction and skills. More intelligent otolaryngology training models will be developed in the future.
- Open Access
- 30 April 2025
- Published by Wiley in World Journal of Otorhinolaryngology - Head and Neck Surgery
- Vol. 12 (3) , 338-345
Deep Learning for Endoscopic Classification of Adenoid Hypertrophy
Objective: Endoscopy is a convenient and widely used method to evaluate adenoid size, but the subjectivity of its image diagnosis can result in over‐ or underestimation. To create a new assessment strategy for adenoid hypertrophy, we developed a reliable method for automated classification using a deep learning algorithm with nasal endoscopic images. Methods: Endoscopic images of adenoids were obtained from our institution and were divided into four grades based on choanal obstruction. The labeled images were randomly assigned to training and testing sets. The convolutional neural network (CNN) algorithm Xception was used and tuned on the training set. The classification performance was assessed on the test data using the optimal model. Results: Twenty‐six thousand and sixty endoscopic images of adenoids were included and classified into four grades (5500 for Grade Ⅰ, 5452 for Grade Ⅱ, 7453 for Grade Ⅲ, and 7655 for Grade Ⅳ). The Xception model achieved an overall classification accuracy of 95.53%. When evaluated by receiver operating characteristic curves (ROCs), the area under the curves (AUCs) of Grades Ⅰ– Ⅳ were 0.93, 0.94, 0.97, and 0.91, respectively. Conclusion: Artificial intelligence is effective in the classification of endoscopic adenoidal hypertrophy. The deep learning approach may be beneficial in improving the efficiency, objectivity, and stability of diagnosis.
- 30 April 2025
- Published by Wiley in World Journal of Otorhinolaryngology - Head and Neck Surgery
- Vol. 12 (3) , 338-345
Open AccessDeep Learning for Endoscopic Classification of Adenoid Hypertrophy
Objective: Endoscopy is a convenient and widely used method to evaluate adenoid size, but the subjectivity of its image diagnosis can result in over‐ or underestimation. To create a new assessment strategy for adenoid hypertrophy, we developed a reliable method for automated classification using a deep learning algorithm with nasal endoscopic images. Methods: Endoscopic images of adenoids were obtained from our institution and were divided into four grades based on choanal obstruction. The labeled images were randomly assigned to training and testing sets. The convolutional neural network (CNN) algorithm Xception was used and tuned on the training set. The classification performance was assessed on the test data using the optimal model. Results: Twenty‐six thousand and sixty endoscopic images of adenoids were included and classified into four grades (5500 for Grade Ⅰ, 5452 for Grade Ⅱ, 7453 for Grade Ⅲ, and 7655 for Grade Ⅳ). The Xception model achieved an overall classification accuracy of 95.53%. When evaluated by receiver operating characteristic curves (ROCs), the area under the curves (AUCs) of Grades Ⅰ– Ⅳ were 0.93, 0.94, 0.97, and 0.91, respectively. Conclusion: Artificial intelligence is effective in the classification of endoscopic adenoidal hypertrophy. The deep learning approach may be beneficial in improving the efficiency, objectivity, and stability of diagnosis.
- 27 August 2024
- Published by Wiley in The Laryngoscope
- Vol. 135 (1) , 429-437
Long‐term Results of Endoscopic Percutaneous Suture Lateralization for Newborns with Bilateral Vocal Cord Paralysis
Purpose: Bilateral vocal fold paralysis (BVFP) is a critical condition in newborns, which may present with significant airway distress necessitating tracheostomy. The purpose of this study is to report the safety and effectiveness of endoscopic percutaneous suture lateralization (EPSL) for newborns with BVFP, and evaluated the long‐term results and the stability of the lateralization.Methods: A review of patients undergoing EPSL for BVFP at our institutions was performed between October 2018 and June 2023. Preoperative and postoperative clinical information was collected. The functional outcomes of the surgery in terms of breathing, voice, and swallowing were evaluated and recorded.Results: Twenty seven patients were included, with a median age at diagnosis of 12 days (range, 1–33 days). The maximum follow‐up is for 5 years. EPSL was successful in 77.8% of cases, effectively avoiding the need for tracheostomy. Dyspnea was relieved within a month after surgery, enabling patients to tolerate oral feeds within 2 months after surgery. Notably, some patients experienced a return of vocal fold function, particularly in successful EPSL cases, underlining the procedure's efficacy. Minor complications, including granulation tissue and wound infection, were observed but were manageable. Major complications were notably absent. The results are durable and stable at long‐term follow‐up.Conclusion: EPSL for BVFP is a relatively simple, minimally invasive, non‐destructive, safe, and effective procedure in newborns, which may avoid the need for a tracheostomy, preserves the laryngeal framework, and does not affect the natural recovery of vocal cords.Level of Evidence: Level 3: retrospective case series Laryngoscope, 2024
- 27 August 2024
- Published by Wiley in The Laryngoscope
- Vol. 135 (1) , 429-437
Long‐term Results of Endoscopic Percutaneous Suture Lateralization for Newborns with Bilateral Vocal Cord Paralysis
Purpose: Bilateral vocal fold paralysis (BVFP) is a critical condition in newborns, which may present with significant airway distress necessitating tracheostomy. The purpose of this study is to report the safety and effectiveness of endoscopic percutaneous suture lateralization (EPSL) for newborns with BVFP, and evaluated the long‐term results and the stability of the lateralization.Methods: A review of patients undergoing EPSL for BVFP at our institutions was performed between October 2018 and June 2023. Preoperative and postoperative clinical information was collected. The functional outcomes of the surgery in terms of breathing, voice, and swallowing were evaluated and recorded.Results: Twenty seven patients were included, with a median age at diagnosis of 12 days (range, 1–33 days). The maximum follow‐up is for 5 years. EPSL was successful in 77.8% of cases, effectively avoiding the need for tracheostomy. Dyspnea was relieved within a month after surgery, enabling patients to tolerate oral feeds within 2 months after surgery. Notably, some patients experienced a return of vocal fold function, particularly in successful EPSL cases, underlining the procedure's efficacy. Minor complications, including granulation tissue and wound infection, were observed but were manageable. Major complications were notably absent. The results are durable and stable at long‐term follow‐up.Conclusion: EPSL for BVFP is a relatively simple, minimally invasive, non‐destructive, safe, and effective procedure in newborns, which may avoid the need for a tracheostomy, preserves the laryngeal framework, and does not affect the natural recovery of vocal cords.Level of Evidence: Level 3: retrospective case series Laryngoscope, 2024
- Open Access
- 19 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 32 (15344320) , 3179-3188
ABR-Attention: An Attention-Based Model for Precisely Localizing Auditory Brainstem Response
Auditory Brainstem Response (ABR) is an evoked potential in the brainstem’s neural centers in response to sound stimuli. Clinically, characteristic waves, especially Wave V latency, extracted from ABR can objectively indicate auditory loss and diagnose diseases. Several methods have been developed for the extraction of characteristic waves. To ensure the effectiveness of the method, most of the methods are time-consuming and rely on the heavy workloads of clinicians. To reduce the workload of clinicians, automated extraction methods have been developed. However, the above methods also have limitations. This study introduces a novel deep learning network for automatic extraction of Wave V latency, named ABR-Attention. ABR-Attention model includes a self-attention module, first and second-derivative attention module, and regressor module. Experiments are conducted on the accuracy with 10-fold cross-validation, the effects on different sound pressure levels (SPLs), the effects of different error scales and the effects of ablation. ABR-Attention shows efficacy in extracting Wave V latency of ABR, with an overall accuracy of 96.76±0.41% and an error scale of 0.1ms, and provides a new solution for objective localization of ABR characteristic waves.
- 19 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 32 (15344320) , 3179-3188
Open AccessABR-Attention: An Attention-Based Model for Precisely Localizing Auditory Brainstem Response
Auditory Brainstem Response (ABR) is an evoked potential in the brainstem’s neural centers in response to sound stimuli. Clinically, characteristic waves, especially Wave V latency, extracted from ABR can objectively indicate auditory loss and diagnose diseases. Several methods have been developed for the extraction of characteristic waves. To ensure the effectiveness of the method, most of the methods are time-consuming and rely on the heavy workloads of clinicians. To reduce the workload of clinicians, automated extraction methods have been developed. However, the above methods also have limitations. This study introduces a novel deep learning network for automatic extraction of Wave V latency, named ABR-Attention. ABR-Attention model includes a self-attention module, first and second-derivative attention module, and regressor module. Experiments are conducted on the accuracy with 10-fold cross-validation, the effects on different sound pressure levels (SPLs), the effects of different error scales and the effects of ablation. ABR-Attention shows efficacy in extracting Wave V latency of ABR, with an overall accuracy of 96.76±0.41% and an error scale of 0.1ms, and provides a new solution for objective localization of ABR characteristic waves.
- Open Access
- 28 July 2023
- Published by SAGE Publications in Ear, Nose & Throat Journal
- Vol. 105 (3)
Outcomes and Prognostic Factors of Balloon Eustachian Tuboplasty Combined With Ventilation Tubes Insertion in Children: A Retrospective Study
Objective: To evaluate the efficacy and safety of balloon eustachian tuboplasty (BET) combined with ventilation tube (VT) insertion in pediatric population and to identify the predictive factors for symptom recurrence. Methods: We conducted a retrospective study between August 2018 and February 2022 at Shenzhen Children’s Hospital. The study analyzed the data of pediatric patients who underwent BET + VT insertion, as well as the data of pediatric patients who underwent VT insertion alone. The outcomes were efficacy, safety, and predictive factors of BET combined with VT. Kaplan‒Meier curves were used to examine the failure-free survival rate. A multivariate Cox regression model was used to identify the independent predictors of BET failure. Results: We evaluated the data of 29 pediatric patients (48 ears) who underwent BET with VT insertion (BET + VT group) and the data of 29 pediatric patients (46 ears) who underwent VT insertion alone (VT group). The total effectiveness rates at the first follow-up after VT removal and at 12 months in the BET + VT group were 90.9% and 84.6%, respectively. The decrease in the air-bone gap (ABG) was more significant in the BET + VT group at 12 months (13.7 ± 10.8 vs 6.4 ± 15.3, P < .05). The subgroup analyses did not show any significant difference between the groups in high-risk. For non-high-risk patients, the decrease in the ABG was more significant in the BET + VT group (14.2 ± 10.6 vs 4.3 ± 13.1, P < .05) at 12 months. The multivariate analysis showed that a history of VT insertion was independently associated with a higher rate of recurrence in the BET + VT group (hazard ratio 3.177; 95% CI, 1.027-9.826; P < .05). Conclusions: BET + VT insertion is an effective procedure to decrease the ABG in pediatric patients with eustachian tube dysfunction (ETD) who have no risk factors for conventional therapy failure. Treatment of patients with ETDs who have coexisting risk factors remains a challenge that warrants further high-quality prospective research.
- 28 July 2023
- Published by SAGE Publications in Ear, Nose & Throat Journal
- Vol. 105 (3)
Open AccessOutcomes and Prognostic Factors of Balloon Eustachian Tuboplasty Combined With Ventilation Tubes Insertion in Children: A Retrospective Study
Objective: To evaluate the efficacy and safety of balloon eustachian tuboplasty (BET) combined with ventilation tube (VT) insertion in pediatric population and to identify the predictive factors for symptom recurrence. Methods: We conducted a retrospective study between August 2018 and February 2022 at Shenzhen Children’s Hospital. The study analyzed the data of pediatric patients who underwent BET + VT insertion, as well as the data of pediatric patients who underwent VT insertion alone. The outcomes were efficacy, safety, and predictive factors of BET combined with VT. Kaplan‒Meier curves were used to examine the failure-free survival rate. A multivariate Cox regression model was used to identify the independent predictors of BET failure. Results: We evaluated the data of 29 pediatric patients (48 ears) who underwent BET with VT insertion (BET + VT group) and the data of 29 pediatric patients (46 ears) who underwent VT insertion alone (VT group). The total effectiveness rates at the first follow-up after VT removal and at 12 months in the BET + VT group were 90.9% and 84.6%, respectively. The decrease in the air-bone gap (ABG) was more significant in the BET + VT group at 12 months (13.7 ± 10.8 vs 6.4 ± 15.3, P < .05). The subgroup analyses did not show any significant difference between the groups in high-risk. For non-high-risk patients, the decrease in the ABG was more significant in the BET + VT group (14.2 ± 10.6 vs 4.3 ± 13.1, P < .05) at 12 months. The multivariate analysis showed that a history of VT insertion was independently associated with a higher rate of recurrence in the BET + VT group (hazard ratio 3.177; 95% CI, 1.027-9.826; P < .05). Conclusions: BET + VT insertion is an effective procedure to decrease the ABG in pediatric patients with eustachian tube dysfunction (ETD) who have no risk factors for conventional therapy failure. Treatment of patients with ETDs who have coexisting risk factors remains a challenge that warrants further high-quality prospective research.