Hiroaki Watanabe
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hiroaki Watanabe has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Kazuomi Kario
Division of Cardiovascular Medicine, Department of Medicine, Jichi Medical University School of Medicine, Tochigi, Japan.
2 shared publications - Masashi Kamioka
Division of Cardiovascular Medicine, Department of Medicine, Jichi Medical University School of Medicine, Shimotsuke, Japan
2 shared publications - Tomonori Watanabe
Division of Cardiovascular Medicine, Department of Medicine Jichi Medical University School of Medicine Tochigi Japan
2 shared publications Ayako Yokota
Division of Cardiovascular Medicine, Department of Medicine, Jichi Medical University School of Medicine , 3311-1 Yakushiji, Shimotsuke 329-0498 , Japan
1 shared publicationHaruka Iwama
Division of Cardiovascular Medicine, Department of Medicine, Jichi Medical University School of Medicine , 3311-1 Yakushiji, Shimotsuke City 329-0498
1 shared publication- Hisaki Makimoto
Division of Cardiovascular Medicine, Department of Medicine Jichi Medical University School of Medicine Tochigi Japan
1 shared publication
Latest Publications
- Open Access
- 25 February 2025
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
- Vol. 9 (3) , ytaf101
Pulmonary vein stenosis requiring angioplasty or surgical treatment following pulmonary vein isolation: case series
Background: Pulmonary vein stenosis (PVS) after pulmonary vein isolation (PVI) is a rare but severe complication. Its severity depends on the cause, number of stenosed veins, and symptoms. For symptomatic patients, angioplasty is the first choice, while surgery is not recommended due to its high invasiveness. Case summary: Patient 1: A 60-year-old male developed symptomatic left superior and inferior PVS after two procedures of PVI using radiofrequency energy. Eight-millimetre stent in left-superior and 7-mm stent in left-inferior PV were placed. Patient 2: A 64-year-old male underwent PVI using radiofrequency energy with a high-power short-duration setting. Although the patient was asymptomatic, CT revealed left-inferior PVS along with infiltrative shadow of the same area. Considering the risk of pulmonary infarction and with the patient’s informed consent, a 7-mm diameter stent was placed. Patient 3: A 56-year-old male underwent PVI with a 28-mm cryoballoon, followed by radiofrequency ablation for bilateral inferior PV reconductions. Subsequently, he developed severe left-inferior PVS, uncontrollable haemoptysis, and pulmonary infarction, necessitating lower lung-lobe resection. Discussion: Classical PVS often results from multiple radiofrequency ablations, as seen in Patients 1 and 3. High-power short-duration ablation, as a novel technique associated with specific risks, should also be acknowledged. While PVS treatment is typically for symptomatic cases, it may be justified in high-risk asymptomatic patients, as in Patient 2. Although not first-line, surgery should be considered in cases with refractory symptoms, as in Patient 3.
- 25 February 2025
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
- Vol. 9 (3) , ytaf101
Open AccessPulmonary vein stenosis requiring angioplasty or surgical treatment following pulmonary vein isolation: case series
Background: Pulmonary vein stenosis (PVS) after pulmonary vein isolation (PVI) is a rare but severe complication. Its severity depends on the cause, number of stenosed veins, and symptoms. For symptomatic patients, angioplasty is the first choice, while surgery is not recommended due to its high invasiveness. Case summary: Patient 1: A 60-year-old male developed symptomatic left superior and inferior PVS after two procedures of PVI using radiofrequency energy. Eight-millimetre stent in left-superior and 7-mm stent in left-inferior PV were placed. Patient 2: A 64-year-old male underwent PVI using radiofrequency energy with a high-power short-duration setting. Although the patient was asymptomatic, CT revealed left-inferior PVS along with infiltrative shadow of the same area. Considering the risk of pulmonary infarction and with the patient’s informed consent, a 7-mm diameter stent was placed. Patient 3: A 56-year-old male underwent PVI with a 28-mm cryoballoon, followed by radiofrequency ablation for bilateral inferior PV reconductions. Subsequently, he developed severe left-inferior PVS, uncontrollable haemoptysis, and pulmonary infarction, necessitating lower lung-lobe resection. Discussion: Classical PVS often results from multiple radiofrequency ablations, as seen in Patients 1 and 3. High-power short-duration ablation, as a novel technique associated with specific risks, should also be acknowledged. While PVS treatment is typically for symptomatic cases, it may be justified in high-risk asymptomatic patients, as in Patient 2. Although not first-line, surgery should be considered in cases with refractory symptoms, as in Patient 3.
- Open Access
- 2 August 2023
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 25 (9)
Unipolar-voltage-based evaluation of left atrial tissue properties and ablation outcome in patients with atrial fibrillation
The relationship between local unipolar voltage (UV) in the pulmonary vein (PV)-ostia and left atrial wall thickness (LAWT) and the utility of these parameters as indices of outcome after atrial fibrillation (AF) ablation remain unclear. Two-hundred seventy-two AF patients who underwent AF ablation were enrolled. Unipolar voltage of PV-ostia was measured using a CARTO system, and LAWT was measured using computed tomography. The primary endpoint was atrial tachyarrhythmia (ATA) recurrence including AF. The ATA recurrence was documented in 74 patients (ATA-Rec group). The UV and LAWT of the bilateral superior PV roof to posterior and around the right-inferior PV in the ATA-Rec group were significantly greater than in patients without ATA recurrence (ATA-Free group) (P < 0.001). The UV had a strong positive correlation with LAWT (R2 = 0.446, P < 0.001). The UV 2.7 mV and the corresponding LAWT 1.6 mm were determined as the cut-off values for ATA recurrence (P < 0.001, respectively). Multisite LA high UV (HUV, ≥4 areas of >2.7 mV) or multisite LA wall thickening (≥5 areas of >1.6 mm), defined as LA hypertrophy (LAH), was related to higher ATA recurrence. Among 92 LAH patients, 66 had HUV (LAH-HUV) and the remaining 26 had low UV (LAH-LUV), characterized by history of non-paroxysmal AF and heart failure, reduced LV ejection fraction, or enlarged LA. In addition, LAH-LUV showed the worst ablation outcome, followed by LAH-HUV and No LAH (log-rank P < 0.001). Combining UV and LAWT enables us to stratify recurrence risk and suggest a tailored ablation strategy according to LA tissue properties.
- 2 August 2023
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 25 (9)
Open AccessUnipolar-voltage-based evaluation of left atrial tissue properties and ablation outcome in patients with atrial fibrillation
The relationship between local unipolar voltage (UV) in the pulmonary vein (PV)-ostia and left atrial wall thickness (LAWT) and the utility of these parameters as indices of outcome after atrial fibrillation (AF) ablation remain unclear. Two-hundred seventy-two AF patients who underwent AF ablation were enrolled. Unipolar voltage of PV-ostia was measured using a CARTO system, and LAWT was measured using computed tomography. The primary endpoint was atrial tachyarrhythmia (ATA) recurrence including AF. The ATA recurrence was documented in 74 patients (ATA-Rec group). The UV and LAWT of the bilateral superior PV roof to posterior and around the right-inferior PV in the ATA-Rec group were significantly greater than in patients without ATA recurrence (ATA-Free group) (P < 0.001). The UV had a strong positive correlation with LAWT (R2 = 0.446, P < 0.001). The UV 2.7 mV and the corresponding LAWT 1.6 mm were determined as the cut-off values for ATA recurrence (P < 0.001, respectively). Multisite LA high UV (HUV, ≥4 areas of >2.7 mV) or multisite LA wall thickening (≥5 areas of >1.6 mm), defined as LA hypertrophy (LAH), was related to higher ATA recurrence. Among 92 LAH patients, 66 had HUV (LAH-HUV) and the remaining 26 had low UV (LAH-LUV), characterized by history of non-paroxysmal AF and heart failure, reduced LV ejection fraction, or enlarged LA. In addition, LAH-LUV showed the worst ablation outcome, followed by LAH-HUV and No LAH (log-rank P < 0.001). Combining UV and LAWT enables us to stratify recurrence risk and suggest a tailored ablation strategy according to LA tissue properties.