GZGerard Zasuwa

Gerard Zasuwa

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Gerard Zasuwa has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Detection of Hemodialysis Venous Needle Dislodgment Using Venous Access Pressure Measurements: A Simulation Study

    by Stanley Frinak, John Kennedy, Gerard Zasuwa, Karla D. Passalacqua, Jerry Yee

    Key Points: Hemodialysis machine pressure alarms may not detect venous needle dislodgment when patients have changes in venous pressure. A cross-sectional analysis of hemodialysis treatment data identified the occurrences of venous pressure changes that would make it hard to trigger a machine alarm. A proof-of-concept use of a data analytic–derived algorithm for the detection of venous needle dislodgments was demonstrated. Background: In rare instances, hemodialysis venous needles may become dislodged, and when left undetected, this can lead to severe injury or death. Although dialysis machines have alarms to detect venous needle dislodgment (VND), their range of detection is limited. An understanding of the clinical conditions that may lead to missed needle dislodgments is needed for the development of more robust detection systems. Methods: We created a sham dialysis circuit with a Fresenius 2008K dialysis machine for in vitro simulation testing of machine alarm behavior under variable conditions. The circuit used a blood substitute and mimicked a patient's venous access site. We varied blood flow rate, venous pressure (VP), and upward drift in VP and analyzed the time to alarm for the machine and an improved alarm algorithm. We also performed a cross-sectional retrospective study to identify the clinical occurrence of VP upward drift between September 1, 2016, and November 1, 2016, in patients on hemodialysis with an arteriovenous fistula. Results: Of 43,390 VP readings for 147 patients on hemodialysis, 16,594 (38%) showed an upward drift in VP (range 20–79 mmHg), with a mean±SD increase of 11±18 mm Hg within 20±14 minutes. A total of 19 VND simulations under different VP and blood flow parameters resulted in 19 (100%) algorithm alarm activations. Only eight simulations (42%) activated a machine alarm, and machine alarm activation time was longer than the algorithm activation time for all eight machine alarms (range 1–13 seconds). Conclusions: Patients can experience changes in VP during hemodialysis which may not trigger a machine alarm in the case of a VND. Our simulations showed that current dialysis machine alarm systems may not compensate for upward drift in VP, and improved algorithms for detecting needle dislodgment during hemodialysis are needed.


  • De novo once-monthly darbepoetin alpha treatment for the anemia of chronic kidney disease using a computerized algorithmic approach

    by E. Chalhoub, S. Frinak, G. Zasuwa, M D Faber, E. Peterson, A. Besarab, J. Yee

    Anemia of chronic kidney disease (CKD) has been traditionally treated by erythropoiesis-stimulating agents (ESAs) and/or iron following manual determination of dose. We hypothesized that once-monthly (QM) algorithmically dosed darbepoetin α (DA) and iron administration would successfully treat anemia of CKD in ESA-naïve CKD subjects. QM DA and iron doses were determined via a computerized program targeting a hemoglobin (Hb) of 10.5 - 12.5 g/dl in anemic, ESA-naïve, CKD Stages 3 - 5 subjects. Six consecutive QM doses were administered. Hb, ferritin, and transferrin saturation were recorded. Data are presented as means ± standard deviation. Anemia was identified in 133 subjects, with a mean follow-up of 188 days. DA doses and Hb were significantly greater at Months 3 and 6 compared to baseline (p < 0.05); DA doses were 109 ± 68 μg and 118 ± 91, respectively, at Months 3 and 6. Hemoglobin levels were correspondingly 11.3 ± 1.1 g/dl and 11.3 ± 1.0. 78% of patients achieved the target Hb by 6 months of therapy. The elevation of Hb was greater in non-proteinuric than proteinuric subjects at 6 months of treatment (11.6 ± 0.8 g/dl vs. 11.0 ± 1.1; p < 0.05), despite lower DA dose (96 ± 76 μg vs. 139 ± 98; p < 0.05). Successful treatment of the anemia of CKD by QM DA based upon a computerized dosing program was achieved by 6 months in 78% of ESA-naïve, CKD subjects.


  • Introduction, demography, and general methods

    by N. Levin, G. Zasuwa, H. Klinkmann

    The International Cooperative Biocompatibility Study was planned to analyse the symptomatic and laboratory response to seven different dialysers studied in five centres in four countries. The dialysers used were the G10-3N, G120 M, CD 4000, T 150, Duo-Flux, F 60, and Filtral (see below for full description). A total of 37 patients in the Veterans Administration Lakeside Medical Center, Chicago; Henry Ford Hospital, Detroit; Osaka City University Hospital, Osaka; Wilhelm Pieck University Hospital, Rostock; and Huddinge University Hospital, Stockholm were studied. All patients had been dialysed for a minimum of 6 months, were non-diabetic, stable, and compliant; and most were middle-aged and male. Patients were treated three times per week for 2 weeks with each new dialyser with random assignment to one of four orders of dialyser use. The same manufacturing lot of each dialyser, blood line sets and needles were used by all centres. Delivery systems were volumetric controlled except for some patients in Osaka treated with negative-pressure equipment. Individual patient prescriptions (Kt/Vs for urea), in use prior to the study, were continued. Kt/Vs for all treatments were derived from reported blood flows and blood water corrected mass transfer coefficients multiplied by dialyser surface area. Clinical data were measure pre-, intra- and postdialysis. Hourly signs, symptoms, drugs, and nursing interventions were recorded using the identical treatment record at all centres. In addition, patients completed a questionnaire form (translated into the appropriate language) at least weekly, relating symptoms experienced with each dialyser. Laboratory investigations were performed during the sixth consecutive treatment.(ABSTRACT TRUNCATED AT 250 WORDS)