S. Dhanaraj
S. Dhanaraj has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Balasubramaniam Pudhupalayam Marimuthu
Department of Electrical and Electronics Engineering, Sri Shakthi Institute of Engineering and Technology, Coimbatore, India
2 shared publications - Sudhakar Sengan
Department of Computer Science and Engineering, Erode Sengunthar Engineering College, Erode, India
2 shared publications - Sujatha Krishnamoorthy
Zhejiang Bioinformatics International Science and Technology Cooperation Center, Wenzhou-Kean University, Wenzhou 325060, China
2 shared publications - Vairavasundaram Subramaniyaswamy
Vellore Institute of Technology
2 shared publications - Venkatesh Sriram
Acharya Bangalore B School (ABBS)
2 shared publications T. Rajesh
Department of Electrical and Electronics Engineering, Malla Reddy Engineering College, Hyderabad 500100, Telangana, India
1 shared publication
Latest Publications
- 2 January 2020
- Published by Taru Publications in Journal of Discrete Mathematical Sciences and Cryptography
- Vol. 24 (1) , 19-34
An efficient control strategy of shunt active power filter for asymmetrical load condition using time domain approach
The article describes the current control scheme for Shunt Active Power Filter (SAPF) meant for setting up on a power system. There is also a supplementary function in the active power filter for eliminating harmonics, correct power factor, and asymmetrical balance load studied in this paper. A brief explanation of the execution of the classical current detection algorithms for active power filters provided. After understanding various severe power excellence problems and a range of commission needs a current control scheme put forth. The system gives shortest time delay when compared with other methodologies. A range of commissioning current references, thus, is precisely and efficiently attained by following the suggested current control approach.The proposed system can assured that to achieve a variety of compensation purposes. The simulation outcomes we arrived with MATLAB / Simulink are proof that our method gives outstanding performance apart from being more effective compared to the existing methods.
- 2 January 2020
- Published by Taru Publications in Journal of Discrete Mathematical Sciences and Cryptography
- Vol. 24 (1) , 19-34
An efficient control strategy of shunt active power filter for asymmetrical load condition using time domain approach
The article describes the current control scheme for Shunt Active Power Filter (SAPF) meant for setting up on a power system. There is also a supplementary function in the active power filter for eliminating harmonics, correct power factor, and asymmetrical balance load studied in this paper. A brief explanation of the execution of the classical current detection algorithms for active power filters provided. After understanding various severe power excellence problems and a range of commission needs a current control scheme put forth. The system gives shortest time delay when compared with other methodologies. A range of commissioning current references, thus, is precisely and efficiently attained by following the suggested current control approach.The proposed system can assured that to achieve a variety of compensation purposes. The simulation outcomes we arrived with MATLAB / Simulink are proof that our method gives outstanding performance apart from being more effective compared to the existing methods.
- 2 January 2020
- Published by Taru Publications in Journal of Discrete Mathematical Sciences and Cryptography
- Vol. 24 (1) , 1-17
Investigation and strategy of intelligent controller (ACBIC) for DC link control in SAPF system for industrial power systems
This article describes the design of the ant colony based fuzzy controller for shunt active power filter is to mitigating harmonics, which is injected by nonlinear loads such as thyristor and rectifies loads. Principally, The design of an ant colony based intelligent controller (ACBIC) designed according to Fuzzy rules, so the system is robust. The optimized membership function and gain of the controller are normalized by the ant colony algorithm and the fine-tuning of the associated activities and stabilization advantages achieved with Ant Colony Optimization (ACO). The simulation results presented and model outcomes demonstrate the best dynamic performance and control operation compared with the classical PI Controller. The optimized PI controller gives a better performance during the high transient time, and it minimizes the settling time. Also, the controller bringing down the harmonics and maintains a good quality of power.
- 2 January 2020
- Published by Taru Publications in Journal of Discrete Mathematical Sciences and Cryptography
- Vol. 24 (1) , 1-17
Investigation and strategy of intelligent controller (ACBIC) for DC link control in SAPF system for industrial power systems
This article describes the design of the ant colony based fuzzy controller for shunt active power filter is to mitigating harmonics, which is injected by nonlinear loads such as thyristor and rectifies loads. Principally, The design of an ant colony based intelligent controller (ACBIC) designed according to Fuzzy rules, so the system is robust. The optimized membership function and gain of the controller are normalized by the ant colony algorithm and the fine-tuning of the associated activities and stabilization advantages achieved with Ant Colony Optimization (ACO). The simulation results presented and model outcomes demonstrate the best dynamic performance and control operation compared with the classical PI Controller. The optimized PI controller gives a better performance during the high transient time, and it minimizes the settling time. Also, the controller bringing down the harmonics and maintains a good quality of power.