Long He
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Long He has a total of 94 co-authors. Here are the top co-authors by number of shared publications:
- Rui Lou
College of Mechanical and Electronic Engineering, Shaanxi University of Science and Technology, Xi’an 710021, China
5 shared publications - Hao Cui
School of Geoscience and Technology, Zhengzhou University, Zhengzhou, China
4 shared publications - Tong Ren
College of Mechanical and Electrical Engineering, Shaanxi University of Science and Technology, Xi’an 710021, China
4 shared publications Yiwen Tao
4 shared publications- Mengzhuo Li
College of Mechanical and Electrical Engineering, Shaanxi University of Science and Technology, Xi’an 710021, China
3 shared publications Rui Lou
3 shared publications
Latest Publications
- Open Access
Impact of Lignin Substitution on the Formation and Physicochemical Properties of Resorcinol–Furfural-Based Carbon Aerogels in Deep Eutectic Solvent
Aligned with green chemistry principles and the pursuit of sustainable synthesis, we developed a lignin–resorcinol–furfural (LRF) gel system within a deep eutectic solvent (DES), in which lignin partially replaces resorcinol and furfural serves as a bio-based alternative to formaldehyde. We further examined the correlation between the lignin substitution ratio (65–90%) and the gelation kinetics, microstructure, and electrochemical performance of the resulting carbon aerogels (LRFC). The findings reveal that the lignin substitution ratio exerts a critical influence on both the crosslinking uniformity and the overall network architecture of the resulting LRFC. The results demonstrated that LRFC65, with a lignin substitution ratio of 65%, exhibited the optimal electrochemical performance: a specific capacitance of 117.2 F g−1 at a current density of 0.2 A g−1, along with lower charge transfer and diffusion resistance. This work offers promising prospects for high-value bio-based furfural and lignin valorization.
Open AccessImpact of Lignin Substitution on the Formation and Physicochemical Properties of Resorcinol–Furfural-Based Carbon Aerogels in Deep Eutectic Solvent
Aligned with green chemistry principles and the pursuit of sustainable synthesis, we developed a lignin–resorcinol–furfural (LRF) gel system within a deep eutectic solvent (DES), in which lignin partially replaces resorcinol and furfural serves as a bio-based alternative to formaldehyde. We further examined the correlation between the lignin substitution ratio (65–90%) and the gelation kinetics, microstructure, and electrochemical performance of the resulting carbon aerogels (LRFC). The findings reveal that the lignin substitution ratio exerts a critical influence on both the crosslinking uniformity and the overall network architecture of the resulting LRFC. The results demonstrated that LRFC65, with a lignin substitution ratio of 65%, exhibited the optimal electrochemical performance: a specific capacitance of 117.2 F g−1 at a current density of 0.2 A g−1, along with lower charge transfer and diffusion resistance. This work offers promising prospects for high-value bio-based furfural and lignin valorization.
- 1 August 2026
- Published by AIP Publishing in Physics of Fluids
- Vol. 38 (8)
Compound droplet jetting induced by surface acoustic wave
Currently, most research on surface acoustic waves (SAW)-driven microdroplet jetting employs single-component droplets for jetting dynamics analysis. However, practical applications typically involve more complex fluids. Compared with single droplets, compound droplets exhibit more complex topological structures, yet the interaction mechanism between SAW and compound droplets remains unclear. Therefore, in this paper, we constructed an oil-in-water compound droplet dispersed in air and investigated the jetting behavior of compound droplets driven by SAW. Our results show: (1) under SAW excitation, five typical dynamic states of compound droplets are observed: weak streaming, vibration, single droplet ejection, compound droplet ejection, and bulk ejection. (2) Due to the law of acoustic wave attenuation, an increasing of droplet radius ratio induces a transition from single droplet ejection to compound droplet ejection state. (3) Meanwhile, an increasing of droplet radius ratio promotes the emergence of vibration and bulk ejection, resulting in a narrower Weber number range for the occurrence of single droplet ejection and compound droplet ejection states. This study is of great significance for optimizing compound droplet generation and provides new insights into the future biomedical applications of microdroplet jetting technology.
- 1 August 2026
- Published by AIP Publishing in Physics of Fluids
- Vol. 38 (8)
Compound droplet jetting induced by surface acoustic wave
Currently, most research on surface acoustic waves (SAW)-driven microdroplet jetting employs single-component droplets for jetting dynamics analysis. However, practical applications typically involve more complex fluids. Compared with single droplets, compound droplets exhibit more complex topological structures, yet the interaction mechanism between SAW and compound droplets remains unclear. Therefore, in this paper, we constructed an oil-in-water compound droplet dispersed in air and investigated the jetting behavior of compound droplets driven by SAW. Our results show: (1) under SAW excitation, five typical dynamic states of compound droplets are observed: weak streaming, vibration, single droplet ejection, compound droplet ejection, and bulk ejection. (2) Due to the law of acoustic wave attenuation, an increasing of droplet radius ratio induces a transition from single droplet ejection to compound droplet ejection state. (3) Meanwhile, an increasing of droplet radius ratio promotes the emergence of vibration and bulk ejection, resulting in a narrower Weber number range for the occurrence of single droplet ejection and compound droplet ejection states. This study is of great significance for optimizing compound droplet generation and provides new insights into the future biomedical applications of microdroplet jetting technology.
- Open Access
Research on Seasonal Heat Exchange in Underground Ventilation Tunnels Based on Field Measurement and CFD Simulation
Amidst global carbon neutrality goals, China’s building energy consumption gains prominence, with heating and cooling exceeding 50% of the total. Underground structures leverage inherent geological thermal inertia to significantly reduce ventilation energy demands. This study employs combined field measurements and numerical simulations to investigate heat exchange mechanisms and performance in underground hydropower station air intake tunnels. Four representative tunnels (Sichuan, Fujian, Hebei, Yunnan) served as case studies, monitoring air temperature, humidity, velocity, and wall temperature. Field-monitored parameters informed a computational fluid dynamics (CFD) model, enabling quantitative analysis of rock thermal conductivity, inlet air velocity, and wall temperature effect on heat exchange efficiency. Research shows that: (1) significant seasonal adaptive characteristics exist, achieving peak cooling efficiency (69.04%, summer) and heating efficiency (78.86%, winter); (2) rock thermal conductivity is the primary efficiency determinant—quartzite tunnels exhibited 11.8% higher average efficiency than tuff tunnels; and (3) inlet air velocity negatively correlates with efficiency, exceeding 90% at 0.1 m/s but declining to 69% at 1.5 m/s. This work provides a theoretical basis for optimizing energy-efficient ventilation in underground engineering and validates the pivotal role of rock thermal inertia in reducing operational building energy consumption.
Open AccessResearch on Seasonal Heat Exchange in Underground Ventilation Tunnels Based on Field Measurement and CFD Simulation
Amidst global carbon neutrality goals, China’s building energy consumption gains prominence, with heating and cooling exceeding 50% of the total. Underground structures leverage inherent geological thermal inertia to significantly reduce ventilation energy demands. This study employs combined field measurements and numerical simulations to investigate heat exchange mechanisms and performance in underground hydropower station air intake tunnels. Four representative tunnels (Sichuan, Fujian, Hebei, Yunnan) served as case studies, monitoring air temperature, humidity, velocity, and wall temperature. Field-monitored parameters informed a computational fluid dynamics (CFD) model, enabling quantitative analysis of rock thermal conductivity, inlet air velocity, and wall temperature effect on heat exchange efficiency. Research shows that: (1) significant seasonal adaptive characteristics exist, achieving peak cooling efficiency (69.04%, summer) and heating efficiency (78.86%, winter); (2) rock thermal conductivity is the primary efficiency determinant—quartzite tunnels exhibited 11.8% higher average efficiency than tuff tunnels; and (3) inlet air velocity negatively correlates with efficiency, exceeding 90% at 0.1 m/s but declining to 69% at 1.5 m/s. This work provides a theoretical basis for optimizing energy-efficient ventilation in underground engineering and validates the pivotal role of rock thermal inertia in reducing operational building energy consumption.
- Open Access
Role of Shear-Thinning-Induced Viscosity Heterogeneity in Regulating Fingering Transition of CO2 Flooding Within Porous Media
During the process of CO2 displacing shear-thinning oil, the occurrence of fingering is a key factor contributing to a reduction in both displacement and sequestration efficiency. Existing studies typically use the average viscosity to calculate the viscosity ratio M for shear-thinning oil, overlooking the non-uniform viscosity distribution resulting from uneven shear stress. Consequently, a phase diagram based on M fails to accurately capture the underlying mechanism influencing fingering. We investigate the influence of shear-thinning on fingering patterns by analyzing viscosity heterogeneity during immiscible CO2 flooding in porous media. The results showed the following: (1) An increase in zero-shear viscosity (μ0) resulted in a greater viscosity difference between the two phases, which intensified interface instability, and the power-law index (n) diminished the shear-thinning effect, promoted fingering formation, and significantly reduced displacement efficiency, with a maximum reduction of 28.6% observed in this study. (2) Shear-thinning oil was more prone to capillary fingering compared to Newtonian oil under the same capillary number Ca and viscosity ratio M. (3) Intense pressure fluctuations at the displacement front combined with non-uniform viscosity distribution exacerbate interfacial instability and make shear-thinning oil more prone to capillary fingering. This study provides guidance for optimizing displacement strategies for shear-thinning fluids and advancing the practical implementation of CO2 flooding technology.
Open AccessRole of Shear-Thinning-Induced Viscosity Heterogeneity in Regulating Fingering Transition of CO2 Flooding Within Porous Media
During the process of CO2 displacing shear-thinning oil, the occurrence of fingering is a key factor contributing to a reduction in both displacement and sequestration efficiency. Existing studies typically use the average viscosity to calculate the viscosity ratio M for shear-thinning oil, overlooking the non-uniform viscosity distribution resulting from uneven shear stress. Consequently, a phase diagram based on M fails to accurately capture the underlying mechanism influencing fingering. We investigate the influence of shear-thinning on fingering patterns by analyzing viscosity heterogeneity during immiscible CO2 flooding in porous media. The results showed the following: (1) An increase in zero-shear viscosity (μ0) resulted in a greater viscosity difference between the two phases, which intensified interface instability, and the power-law index (n) diminished the shear-thinning effect, promoted fingering formation, and significantly reduced displacement efficiency, with a maximum reduction of 28.6% observed in this study. (2) Shear-thinning oil was more prone to capillary fingering compared to Newtonian oil under the same capillary number Ca and viscosity ratio M. (3) Intense pressure fluctuations at the displacement front combined with non-uniform viscosity distribution exacerbate interfacial instability and make shear-thinning oil more prone to capillary fingering. This study provides guidance for optimizing displacement strategies for shear-thinning fluids and advancing the practical implementation of CO2 flooding technology.
- 26 October 2025
- Published by Elsevier in Thermal Science and Engineering Progress
- Vol. 68
Role of thermal Marangoni effect on droplet jetting induced by surface acoustic waves
- 26 October 2025
- Published by Elsevier in Thermal Science and Engineering Progress
- Vol. 68
Role of thermal Marangoni effect on droplet jetting induced by surface acoustic waves
- Open Access
A Theoretical and Test Analysis of Heat and Humidity Transfer for Deeply Buried Underground Corridors with Different Shapes
Moisture generation in the ventilation projects of deeply buried underground corridors affects the underground building environment and personnel health. In order to master the heat and humidity transfer law of underground corridors, this paper establishes a mathematical model by theoretical analysis, and the application of the theoretical model in engineering calculation is verified by a field test. It is found that the ventilation efficiency and heat and humidity transfer effect are related to corridor shape. The results show that under the same cross-sectional area, the average temperature drop and humidity of a rectangular corridor are 0.25% and 0.3% higher than that of an arch corridor, and 0.8% and 0.9% higher than that of a circular corridor. Under the condition of constant section circumference, the average temperature drop and humidity of a rectangular corridor are 0.51% and 0.62% higher than that of an arch corridor, and 1.37% and 1.58% higher than that of a circular corridor. When the equivalent diameter is the same, there is almost no difference in the heat and humidity transfer effect of the three shaped corridors.
Open AccessA Theoretical and Test Analysis of Heat and Humidity Transfer for Deeply Buried Underground Corridors with Different Shapes
Moisture generation in the ventilation projects of deeply buried underground corridors affects the underground building environment and personnel health. In order to master the heat and humidity transfer law of underground corridors, this paper establishes a mathematical model by theoretical analysis, and the application of the theoretical model in engineering calculation is verified by a field test. It is found that the ventilation efficiency and heat and humidity transfer effect are related to corridor shape. The results show that under the same cross-sectional area, the average temperature drop and humidity of a rectangular corridor are 0.25% and 0.3% higher than that of an arch corridor, and 0.8% and 0.9% higher than that of a circular corridor. Under the condition of constant section circumference, the average temperature drop and humidity of a rectangular corridor are 0.51% and 0.62% higher than that of an arch corridor, and 1.37% and 1.58% higher than that of a circular corridor. When the equivalent diameter is the same, there is almost no difference in the heat and humidity transfer effect of the three shaped corridors.