Aleksey A. Voloshenko
Research Subjects
Research Interests
Aleksey A. Voloshenko has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Aleksander A. Kozlov
1 shared publicationAleksander V. Podgrushniy
1 shared publication- Alexei Nikolaevitch Denisov
Academy of the State Fire Service of the Ministry of emergency situations of Russia
1 shared publication Andrey P. Ivannikov
1 shared publicationDepartment of Supervision and Preventive Work of the Ministry of Emergency Situations of Russia
1 shared publication- M. V. Shevtsov
Academy of the State Fire Service of the Ministry of emergency situations of Russia
1 shared publication
Latest Publications
- Open Access
- 3 August 2023
- Published by Southwest State University in Proceedings of the Southwest State University. Series: IT Management, Computer Science, Computer Engineering. Medical Equipment Engineering
- Vol. 13 (2) , 95-111
Information Support for Decision-Making According to the Assessment of Fire-Fighting Distances from the Borders of Open Areas for PBX Storage
The purpose of research. Information support has been developed for decision-making on the assessment of fire-fighting distances from the boundaries of open storage areas for PBX to various objects of protection, taking into account the effects of heat flow. The object of the study is an assessment of the fire-fighting distance from the boundaries of open areas of motor vehicles. The subject of the study is information support for making a management decision on the compliance of the object of protection with fire safety requirements, aimed at limiting the consequences of the spread of fire in the form of a fire-fighting distance from the boundaries of open storage areas for PBX to buildings (structures) of I-V degrees of fire resistance of functional fire hazard classes F.1-F.5. The purpose of this work is to create and application of individual calculation formulas to determine the maximum permissible distances from the boundaries of open areas of vehicles to various buildings (structures) based on the use of a computer software product. Methods. Methods of system analysis, management theory and decision-making, and numerical experiment were used to solve the tasks. Results. The article proposes an assessment of the risk of harm to someone else's property and the determination of the value of the safe distance from the boundaries of open areas for storing PBX to various objects of protection by using the software product «Assessment of the safe distance from the boundaries of open areas of motor vehicles», aimed at improving the scientific and experimental and educational and material base of research, expert and educational organizations. The proposed calculation-based assessment of the compliance of the object of protection with fire safety requirements to prevent the spread of fire is aimed for practical application in the organization of activities and the exercise of powers by employees of the FPS of the Ministry of Emergency Situations of Russia, experts, as well as owners of protection objects. Conclusion. The proposed information support for decision-making on the assessment of fire-fighting distances from the boundaries of open storage areas for PBX will allow you to establish the risk of harm to someone else's property.
- 3 August 2023
- Published by Southwest State University in Proceedings of the Southwest State University. Series: IT Management, Computer Science, Computer Engineering. Medical Equipment Engineering
- Vol. 13 (2) , 95-111
Open AccessInformation Support for Decision-Making According to the Assessment of Fire-Fighting Distances from the Borders of Open Areas for PBX Storage
The purpose of research. Information support has been developed for decision-making on the assessment of fire-fighting distances from the boundaries of open storage areas for PBX to various objects of protection, taking into account the effects of heat flow. The object of the study is an assessment of the fire-fighting distance from the boundaries of open areas of motor vehicles. The subject of the study is information support for making a management decision on the compliance of the object of protection with fire safety requirements, aimed at limiting the consequences of the spread of fire in the form of a fire-fighting distance from the boundaries of open storage areas for PBX to buildings (structures) of I-V degrees of fire resistance of functional fire hazard classes F.1-F.5. The purpose of this work is to create and application of individual calculation formulas to determine the maximum permissible distances from the boundaries of open areas of vehicles to various buildings (structures) based on the use of a computer software product. Methods. Methods of system analysis, management theory and decision-making, and numerical experiment were used to solve the tasks. Results. The article proposes an assessment of the risk of harm to someone else's property and the determination of the value of the safe distance from the boundaries of open areas for storing PBX to various objects of protection by using the software product «Assessment of the safe distance from the boundaries of open areas of motor vehicles», aimed at improving the scientific and experimental and educational and material base of research, expert and educational organizations. The proposed calculation-based assessment of the compliance of the object of protection with fire safety requirements to prevent the spread of fire is aimed for practical application in the organization of activities and the exercise of powers by employees of the FPS of the Ministry of Emergency Situations of Russia, experts, as well as owners of protection objects. Conclusion. The proposed information support for decision-making on the assessment of fire-fighting distances from the boundaries of open storage areas for PBX will allow you to establish the risk of harm to someone else's property.
- 1 January 2023
- Published by State Fire Academy of EMERCOM of Russia in Fire and Emergencies: prevention, elimination
- Vol. 4
Estimated assessment of the sufficiency of forces and means to rescue people in fire
PURPOSE. The process of rescuing people in case of a fire from buildings is hampered by the fact that the only escape routes are staircases, where the chance to run the risk of exposure to fire hazardous factors increases every second. Evacuation from high-rise buildings is limited by the insufficient number of elevators available, which, as the experience of fires in various countries shows, soon after the fire fail. Moreover, firefighters face additional challenges in the form of various adjacent buildings, the presence of vehicles in the parking lot for fire appliances, a lot of electrical equipment and wires near buildings. The authors analyzed the requirements of fire safety, methods and techniques for saving people in case of a fire in a building and revealed problem areas: 1) requirements for saving people do not take into account derived estimates; 2) derived estimates do not take into consideration technical characteristics of turntable ladders (TL) and extension ladders (EL), that affect the time of rescuing people. Considering the fact that the use of derived estimates on requirements effectiveness and organization of fire departments management on rescuing people in case of a fire in a building is impossible in the operational mode, information support was developed to assess rescuing people in case of a fire in a building, taking into account the technical characteristics of TL and EL. METHODS. To solve the set tasks the expert method, system analysis method, control theory and decision-making were used. FINDINGS. The presented information and analytical support will make it possible to assess sufficiency of fire departments means and forces to rescue people from a building using TL, EL. RESEARCH APPLICATION FIELD. Specialists of State Fire Service can apply the derived estimates of rescuing people from a building in case of a fire using TL and EL; heads of enterprises, organizations, as well as persons who legally own, manage or use real estate, property. The latter, including tenants responsible for compliance with the fire regime in premises, buildings rented by them for a certain period according to agreements. CONCLUSIONS. For assessing operational and safe rescuing people in case of a fire in a building, the method for using technical means to rescue people from a building using TL and EL.
- 1 January 2023
- Published by State Fire Academy of EMERCOM of Russia in Fire and Emergencies: prevention, elimination
- Vol. 4
Estimated assessment of the sufficiency of forces and means to rescue people in fire
PURPOSE. The process of rescuing people in case of a fire from buildings is hampered by the fact that the only escape routes are staircases, where the chance to run the risk of exposure to fire hazardous factors increases every second. Evacuation from high-rise buildings is limited by the insufficient number of elevators available, which, as the experience of fires in various countries shows, soon after the fire fail. Moreover, firefighters face additional challenges in the form of various adjacent buildings, the presence of vehicles in the parking lot for fire appliances, a lot of electrical equipment and wires near buildings. The authors analyzed the requirements of fire safety, methods and techniques for saving people in case of a fire in a building and revealed problem areas: 1) requirements for saving people do not take into account derived estimates; 2) derived estimates do not take into consideration technical characteristics of turntable ladders (TL) and extension ladders (EL), that affect the time of rescuing people. Considering the fact that the use of derived estimates on requirements effectiveness and organization of fire departments management on rescuing people in case of a fire in a building is impossible in the operational mode, information support was developed to assess rescuing people in case of a fire in a building, taking into account the technical characteristics of TL and EL. METHODS. To solve the set tasks the expert method, system analysis method, control theory and decision-making were used. FINDINGS. The presented information and analytical support will make it possible to assess sufficiency of fire departments means and forces to rescue people from a building using TL, EL. RESEARCH APPLICATION FIELD. Specialists of State Fire Service can apply the derived estimates of rescuing people from a building in case of a fire using TL and EL; heads of enterprises, organizations, as well as persons who legally own, manage or use real estate, property. The latter, including tenants responsible for compliance with the fire regime in premises, buildings rented by them for a certain period according to agreements. CONCLUSIONS. For assessing operational and safe rescuing people in case of a fire in a building, the method for using technical means to rescue people from a building using TL and EL.
- 1 January 2017
- Published by State Fire Academy of EMERCOM of Russia in Technology of technosphere safety
- Vol. 74
Express-evaluation of heat flow to determine the safe work zones for fire departments
The evaluation of the safe access of the personnel of the fire departments with regard to the influence of the heat flux from a fire was carried out. Key words: safe distance, heat flow, fire departments.
- 1 January 2017
- Published by State Fire Academy of EMERCOM of Russia in Technology of technosphere safety
- Vol. 74
Express-evaluation of heat flow to determine the safe work zones for fire departments
The evaluation of the safe access of the personnel of the fire departments with regard to the influence of the heat flux from a fire was carried out. Key words: safe distance, heat flow, fire departments.