Bjarke Strøm Larsen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Bjarke Strøm Larsen has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Ingunn Tho
Department of Pharmacy, University of Oslo, Oslo, Norway
5 shared publications - Thomas Rades
Department of Pharmacy, Faculty of Health and Medical Sciences, University of Copenhagen, Universitetsparken 2, 2100 Copenhagen, Denmark
3 shared publications - Matthias Manne Knopp
Bioneer:FARMA, Department of Pharmacy, Universitetsparken 2, 2100 Copenhagen, Denmark
2 shared publications - Peter Meiland
Department of Pharmacy, Faculty of Health and Medical Sciences, University of Copenhagen, Universitetsparken 2, 2100 Copenhagen, Denmark
2 shared publications Ago Mrsa
University of Oslo P.O. Box 1068 Blindern
1 shared publicationBeatrice Perissutti
Department of Chemical and Pharmaceutical Sciences, University of Trieste, Via Alfonso Valerio, 6/1, 34127 Trieste, Italy
1 shared publication
Latest Publications
- Open Access
- 3 August 2026
- Published by American Chemical Society (ACS) in Journal of Proteome Research
- Vol. 25 (9) , 4665-4675
Dual Functionality in Whole Blood Microsampling: Combining Plasma Separation and Immunoaffinity Cleanup for LC–MS Based Targeted Protein Analysis
Smart sampling is a concept that combines a traditional microsampling, such as dried blood spot (DBS), with sample preparation initiated at the moment of sampling. In this paper, plasma separation and antibody-based affinity cleanup are integrated into a single 3D-printed sampling device. Our goal was to evaluate and validate the analytical performance of this device for LC-MS-based determination of hCG. The device effectively eliminated red blood cells, significantly reducing hemoglobin interference by more than 93%. Plasma extraction of >80% was achieved from only 20 μL of whole blood. The partial validation in line with the European Medicines Agency’s ICH guidelines showed that the analytical performance of the sampling device was not compromised. Linear correlation coefficients ≥0.991 were achieved (range: 0.5–75 ng/mL). High between-run accuracy for all QC levels were achieved, ranging from 90 to 105% with a corresponding precision of ≤11%. In conclusion, the 3D-printed device offers a robust solution to traditional microsampling limitations, potentially and in the future enabling point-of-care diagnostics with the versatility and ease of established DBS methods. The successful integration of plasma separation and smart sampling enhances analytical sensitivity and specificity, representing a promising tool for advancements in clinical bioanalysis.
- 3 August 2026
- Published by American Chemical Society (ACS) in Journal of Proteome Research
- Vol. 25 (9) , 4665-4675
Open AccessDual Functionality in Whole Blood Microsampling: Combining Plasma Separation and Immunoaffinity Cleanup for LC–MS Based Targeted Protein Analysis
Smart sampling is a concept that combines a traditional microsampling, such as dried blood spot (DBS), with sample preparation initiated at the moment of sampling. In this paper, plasma separation and antibody-based affinity cleanup are integrated into a single 3D-printed sampling device. Our goal was to evaluate and validate the analytical performance of this device for LC-MS-based determination of hCG. The device effectively eliminated red blood cells, significantly reducing hemoglobin interference by more than 93%. Plasma extraction of >80% was achieved from only 20 μL of whole blood. The partial validation in line with the European Medicines Agency’s ICH guidelines showed that the analytical performance of the sampling device was not compromised. Linear correlation coefficients ≥0.991 were achieved (range: 0.5–75 ng/mL). High between-run accuracy for all QC levels were achieved, ranging from 90 to 105% with a corresponding precision of ≤11%. In conclusion, the 3D-printed device offers a robust solution to traditional microsampling limitations, potentially and in the future enabling point-of-care diagnostics with the versatility and ease of established DBS methods. The successful integration of plasma separation and smart sampling enhances analytical sensitivity and specificity, representing a promising tool for advancements in clinical bioanalysis.
- Open Access
- 3 September 2025
- Published by MDPI AG in Pharmaceutics
- Vol. 17 (9) , 1155
Strategies for Assessing Physical Compatibility of Calcium Folinate with Bicarbonate During Methotrexate Rescue Therapy in Pediatric Patients with Acute Lymphoblastic Leukemia
Background/Objectives: Acute lymphoblastic leukemia (ALL) is the most prevalent childhood cancer requiring cytotoxic methotrexate treatment. This always necessitates intravenous administration of rescue therapy consisting of calcium folinate and bicarbonate. Current recommendations advise against mixing these two drugs due to concerns regarding precipitate formation of calcium carbonate (CaCO3) that could result in catheter and capillary obstruction. These recommendations are based on drug concentrations not clinically relevant in pediatric ALL settings. Our study investigated the effect of clinically relevant calcium folinate–bicarbonate concentrations on the risk of CaCO3 precipitation. Methods: A theoretical prediction model provided estimates of final mixing concentrations in five scenarios: three simulated pediatric patient models (approx. 1, 9, and 14 years), an undiluted drug mix, and a high-risk control outlier case. Physical compatibility tests were conducted using validated methods for particle detection, complemented by Raman spectroscopy for particle identification. Results: Theoretical predictions suggested CaCO3 precipitation with elevated bicarbonate concentrations and pH levels. Our simulated patient models and high-risk control outlier case showed that CaCO3 precipitation may be avoided below certain serum methotrexate concentrations and thereby calcium folinate and bicarbonate concentrations. Physical testing demonstrated particle formation only in the undiluted mix with Raman spectroscopy confirming the finding. Conclusions: Mixing calcium folinate and bicarbonate appears safe under specific methotrexate-directed pediatric ALL treatment conditions. While high bicarbonate concentrations pose precipitation risks, protocol-based dosing regimens mitigate this. Switching to disodium folinate or using in-line filters could further enhance co-administration safety if bicarbonate concentrations exceed the safety limit suggested by our results.
- 3 September 2025
- Published by MDPI AG in Pharmaceutics
- Vol. 17 (9) , 1155
Open AccessStrategies for Assessing Physical Compatibility of Calcium Folinate with Bicarbonate During Methotrexate Rescue Therapy in Pediatric Patients with Acute Lymphoblastic Leukemia
Background/Objectives: Acute lymphoblastic leukemia (ALL) is the most prevalent childhood cancer requiring cytotoxic methotrexate treatment. This always necessitates intravenous administration of rescue therapy consisting of calcium folinate and bicarbonate. Current recommendations advise against mixing these two drugs due to concerns regarding precipitate formation of calcium carbonate (CaCO3) that could result in catheter and capillary obstruction. These recommendations are based on drug concentrations not clinically relevant in pediatric ALL settings. Our study investigated the effect of clinically relevant calcium folinate–bicarbonate concentrations on the risk of CaCO3 precipitation. Methods: A theoretical prediction model provided estimates of final mixing concentrations in five scenarios: three simulated pediatric patient models (approx. 1, 9, and 14 years), an undiluted drug mix, and a high-risk control outlier case. Physical compatibility tests were conducted using validated methods for particle detection, complemented by Raman spectroscopy for particle identification. Results: Theoretical predictions suggested CaCO3 precipitation with elevated bicarbonate concentrations and pH levels. Our simulated patient models and high-risk control outlier case showed that CaCO3 precipitation may be avoided below certain serum methotrexate concentrations and thereby calcium folinate and bicarbonate concentrations. Physical testing demonstrated particle formation only in the undiluted mix with Raman spectroscopy confirming the finding. Conclusions: Mixing calcium folinate and bicarbonate appears safe under specific methotrexate-directed pediatric ALL treatment conditions. While high bicarbonate concentrations pose precipitation risks, protocol-based dosing regimens mitigate this. Switching to disodium folinate or using in-line filters could further enhance co-administration safety if bicarbonate concentrations exceed the safety limit suggested by our results.
- Open Access
- 1 September 2024
- Published by Elsevier in European Journal of Pharmaceutics and Biopharmaceutics
- Vol. 203, 114478
A unifying approach to drug-in-polymer solubility prediction: Streamlining experimental workflow and analysis
- 1 September 2024
- Published by Elsevier in European Journal of Pharmaceutics and Biopharmaceutics
- Vol. 203, 114478
Open AccessA unifying approach to drug-in-polymer solubility prediction: Streamlining experimental workflow and analysis
- 9 August 2024
- Published by Elsevier in International Journal of Pharmaceutics
- Vol. 662, 124554
Corrigendum to “A new method to determine drug-polymer solubility through enthalpy of melting and mixing” [Int. J. Pharm., 629, 122391]
- 9 August 2024
- Published by Elsevier in International Journal of Pharmaceutics
- Vol. 662, 124554
Corrigendum to “A new method to determine drug-polymer solubility through enthalpy of melting and mixing” [Int. J. Pharm., 629, 122391]
- Open Access
- 16 December 2023
- Published by Elsevier in Journal of Pharmaceutical Sciences
- Vol. 113 (5) , 1319-1329
Shifting the Focus from Dissolution to Permeation: Introducing the Meso-fluidic Chip for Permeability Assessment (MCPA)
- 16 December 2023
- Published by Elsevier in Journal of Pharmaceutical Sciences
- Vol. 113 (5) , 1319-1329
Open AccessShifting the Focus from Dissolution to Permeation: Introducing the Meso-fluidic Chip for Permeability Assessment (MCPA)
- Open Access
- 21 October 2023
- Published by Elsevier in European Journal of Pharmaceutical Sciences
- Vol. 192, 106619
Impact of drug load and polymer molecular weight on the 3D microstructure of printed tablets
- 21 October 2023
- Published by Elsevier in European Journal of Pharmaceutical Sciences
- Vol. 192, 106619
Open AccessImpact of drug load and polymer molecular weight on the 3D microstructure of printed tablets
- Open Access
- 13 November 2022
- Published by Elsevier in International Journal of Pharmaceutics
- Vol. 629, 122391
A new method to determine drug-polymer solubility through enthalpy of melting and mixing
- 13 November 2022
- Published by Elsevier in International Journal of Pharmaceutics
- Vol. 629, 122391
Open AccessA new method to determine drug-polymer solubility through enthalpy of melting and mixing