JDJana Djounova

Jana Djounova

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jana Djounova has a total of 6 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Indoor radon concentrations in kindergartens in three Bulgarian districts

    by Nina Chobanova, Bistra Kunovska, Desislava Djunakova, Jana Djounova, Zdenka Stojanovska, Antoaneta Angelova, Kremena Ivanova

    This article examines the results of a study of radon concentrations in kindergartens in three districts of north-western Bulgaria. For the period from December 2019 to May 2020, passive radon measurements were accomplished in 1490 premises of 130 kindergartens. The highest arithmetic mean (AM) value of 219 Bq m−3 and geometric mean (GM) value of 156 Bq m−3 radon concentration were found in the state kindergartens of the Vratsa district. The radon values for the remaining two districts are as follows: Lovech—AM = 156 Bq m−3 and GM = 114 Bq m−3; Montana—AM = 125 Bq m−3 and GM = 88 Bq m−3. The effects of various factors on the radon concentration including district, year of building construction, presence of basement, place of premise, wall, and floor interior covering materials, and presence of a ventilation system were investigated. Factor Analysis was used to assess the combined effects of those factors on indoor radon concentration. The results revealed three combinations of the investigated factors: the first combined the district in which the kindergartens were located and the materials used for the floor of the premises, the second combined the year of construction of the building and the presence of a building foundation, and the third combined the rest of the investigated factors. It is concluded that a regional assessment of predictors of radon variability is needed. The walls in kindergartens should not be covered by gypsum, and floors should not be made from materials that can easily develop cracks such as terra cotta. The installation of a ventilation system reduces the radon concentrations in the premises, which is of particular importance in cases where the measured value is above the national reference levels.


  • Open Access

    MEASUREMENT OF GAMMA DOSE RATE IN HOSPITALS FOR REHABILITATION IN BULGARIA

    by Desislava Djunakova, Bistra Kunovska, Nina Chobanova, Jana Djounova, Kremena Ivanova, Zdenka Stojanovska

    The objective of this study was to evaluate the indoor gamma dose rate in 17 inspected hospitals for rehabilitation where the radon measurements were conducted and to give a more comprehensive evaluation of the total exposure dose. The gamma dose rate in the air was measured in 355 rooms in 17 inspected hospitals for rehabilitation on the territory of Bulgaria. The maximum parameter value was 0.390 μSv/h and the minimum value was 0.06 μSv/h with the 0.157 μSv/h arithmetic mean (standard deviation - 0.160). The gamma dose rate was within the natural variations of the parameter in buildings. Direct measurements of radon were conducted, and the results ranged from 12 Bq/m3 to 3920 Bq/m3. The relationship between the two parameters was examined. A weak correlation between gamma dose rate and indoor radon concentration was found. The measurement of a gamma dose rate could be a useful parameter for carrying out radon workplace control. Keywords: gamma dose rate, hospitals, radon, direct measurement. 1. INTRODUCTION Natural radioactivity is an integral part of our environment. Humans